Choosing a Typical Resistor for a 4 Ohm Decade Step

The choice depends on tolerance: E12 provides 3.3 Ω and 3.9 Ω at 10% tolerance, E24 provides 3.9 Ω at 5%, and E96 provides 4.02 Ω at 1%, with 4.00 Ω available in the E192 series at 0.1%, 0.25%, or 0.5% tolerance [S2][S3].

What Counts as a 4 Ohm Decade Step

A resistance decade contains values arranged on a logarithmic scale, with each successive decade differing by a factor of 10, such as 1 Ω to 10 Ω, 10 Ω to 100 Ω, and 100 Ω to 1,000 Ω [S1][S2]. The “4 Ω step” therefore identifies one nominal position in a decade rather than defining a universally available component value.

For example, 4.7 Ω from the E24 series can be scaled by powers of 10 to produce 0.47 Ω, 4.7 Ω, 47 Ω, 470 Ω, 4.7 kΩ, 47 kΩ, 470 kΩ, or 4.7 MΩ [S5]. A 4 Ω nominal step follows the same decimal convention, although 4 Ω itself is not an E24 entry.

Precision decade-resistance equipment uses selectable decades, and a documented GenRad 1433 range extends from 1 mΩ to 111 MΩ across models with 3 through 11 decades [S4]. That equipment is a switchable resistance standard, not simply a collection of ordinary fixed resistors.

Preferred Series Compared by Tolerance and Resolution

The E12 series provides 12 preferred values per decade at ±10% tolerance, the E24 series provides 24 values at ±2% or ±5%, the E96 series provides 96 values at ±1%, and the E192 series provides 192 values at ±0.1%, ±0.25%, or ±0.5% [S2]. More values per decade create a finer spacing around the 4 Ω target.

The choice can be lined up against four practical criteria:

E12 versus E24: E12 has 12 values per decade and is normally associated with ±10% tolerance, while E24 has 24 values and is normally associated with ±5% tolerance. E24 gives the lower-value choice of 3.9 Ω, whereas E12 includes 3.3 Ω and 3.9 Ω as its nearby entries [S1][S5].

E24 versus E96: E24 places the nominal 4 Ω step at 3.9 Ω, producing a nominal error of -0.1 Ω or -2.5% before the resistor’s own tolerance. E96 includes 4.02 Ω, giving a nominal error of +0.02 Ω or +0.5%, with the series classified at ±1% tolerance [S2][S3].

E96 versus E192: E96 contains 4.02 Ω, while E192 contains 4.00 Ω, so the higher-density series supports an almost exact nominal target. The E192 table assigns that 4.00 Ω value to tolerance classes of ±0.1%, ±0.25%, and ±0.5% [S2].

For ordinary decade-box or laboratory selection, 3.9 Ω is the normal answer for a nominal 4 Ω position. For an accurately calibrated resistance standard, 4.00 Ω is the more appropriate selected value if the required tolerance and availability justify the higher cost.

Why 3.9 Ohm Is the Practical 4 Ohm Selection

what is the typical resistor value used for a 4 ohm decade step? - Why 3.9 Ohm Is the Practical 4 Ohm Selection
what is the typical resistor value used for a 4 ohm decade step? - Why 3.9 Ohm Is the Practical 4 Ohm Selection

This is the value normally selected when a 4 Ω decade step is specified using a conventional 5% resistor series.

A 3.9 Ω resistor at ±5% tolerance can measure from 3.705 Ω to 4.095 Ω at the tolerance limits. The maximum-value limit therefore exceeds 4 Ω, but the minimum limit is 0.295 Ω below the nominal 4 Ω position. If every dial position must remain above or below a defined 4 Ω reference, a 3.9 Ω part does not satisfy that requirement without compensation.

For comparison, a 4.02 Ω resistor at ±1% tolerance spans 3.9798 Ω to 4.0602 Ω. The quoted E96 part is only 0.5% above 4 Ω before its tolerance is applied, so it is a closer nominal match than 3.9 Ω when the decade position is intended to read exactly 4 Ω [S2][S3].

The wording on the drawing or calibration certificate must therefore be checked before substitution. A “4 Ω decade step” can mean an exact 4.00 Ω nominal value, a 3.9 Ω preferred value in an E24 decade, or a generated resistance whose actual value includes contact, lead, switch, and measurement errors.

Application Suitability and Practical Limits

A 3.9 Ω E24 resistor is suitable for general test circuits, decade-box construction, and measurements where ±5% nominal series accuracy is acceptable. It is less suitable when the 4 Ω position must agree closely with a calibrated reference, because the resistor’s -2.5% nominal offset introduces a predictable error before switch and contact resistance are considered. [S2]

The 1433 precision decade box covers resistance values from 1 mΩ to over 111 MΩ, with 3 through 11 decades available [S4].

For checking a resistance or conductivity meter, the stated resistance per step, dial-contact resistance, insulation leakage, and calibration accuracy all matter; the nominal 3.9 Ω or 4.00 Ω label alone does not define total uncertainty.

The resistance shown by each dial should be checked against the equipment specifications. A higher decade value can carry a specified maximum current of 0.8 A for the 10 Ω decade, while the 100 Ω decade is listed at 0.25 A and 2.5 V in the same precision-box specification [S4].

High-Frequency and Temperature Effects in Decade Boxes

what is the typical resistor value used for a 4 ohm decade step? - High-Frequency and Temperature Effects in Decade Boxes
what is the typical resistor value used for a 4 ohm decade step? - High-Frequency and Temperature Effects in Decade Boxes

Frequency changes the usable resistance of a decade box because resistance elements, switches, wiring, and stray capacitance do not form an ideal resistor.

At 1 MHz, the same specification gives zero resistance as 0.04 Ω per dial, compared with 0.001 Ω per decade at dc [S4]. For a nominal 4 Ω step, this means the switching network and interconnect cannot be ignored in high-frequency calculations even though the principal resistor is nominally below 5 Ω.

Temperature also changes the assembly. The documented room-temperature coefficient is below 10 ppm/°C for 100 Ω and higher and +20 ppm/°C for 10 Ω and below, while the 0.1 Ω and 0.01 Ω assemblies have a higher overall coefficient [S4]. A 4 Ω position falls in the low-value region where this additional assembly effect should be included in an uncertainty budget.

Precision measurements should also record which decade is active, the dial setting, test frequency, and ambient temperature. Those four variables distinguish a nominal 4 Ω resistance from the effective value presented to the instrument terminals.

Decade Interpretation and Selection Record

A decade in a resistance box is a tenfold range, and each dial contributes a selected step within its assigned decade. The interpretation matters because 4 Ω can be generated by a 4 Ω step alone or by a combination such as 3 Ω plus 1 Ω if those values are available on separate dials [S1].

For a procurement or engineering record, specify the actual resistance, tolerance series, and test condition. Suitable descriptions include “3.9 Ω, E24 preferred value, 5% tolerance” for a conventional 10-step position, “4.02 Ω, E96 preferred value, 1% tolerance” for a closer nominal match, or “4.00 Ω, E192 preferred value” for a precision position [S2][S3].

The trackable decision signal is the value actually printed on the decade-box schematic or calibration record. If it specifies 3.9 Ω, the answer to the typical-value question is 3.9 Ω; if it specifies an exact 4.00 Ω, using 3.9 Ω introduces a -0.1 Ω nominal offset and is not an equivalent replacement.

Frequently asked questions

What is the typical E24 resistor value selected for a nominal 4 Ω decade step?

Use 3.9 Ω, the nearest E24 preferred value to 4 Ω. It is a 5%-tolerance series value with a nominal offset of −0.1 Ω, or −2.5%, before tolerance and other errors are considered.

Which preferred-value series provides a closer nominal match to 4 Ω for a calibrated resistance standard?

E192 provides an exact 4.00 Ω nominal value at ±0.1%, ±0.25%, or ±0.5% tolerance. E96 is also close, using 4.02 Ω at ±1% tolerance, for a nominal offset of +0.02 Ω or +0.5%.

What is the resistance range of a 3.9 Ω resistor specified at ±5% tolerance?

At the tolerance limits, a 3.9 Ω ±5% resistor measures from 3.705 Ω to 4.095 Ω. Its lower limit is 0.295 Ω below the nominal 4 Ω position.

Can a 3.9 Ω E24 resistor replace an exact 4.00 Ω position in a calibrated decade box?

Not without compensation if the position must remain at or above a defined 4 Ω reference, because its minimum value is 3.705 Ω at ±5% tolerance. A 4.00 Ω E192 part is the more appropriate choice for an accurately calibrated standard when its tolerance and cost are acceptable.

7 sources
  1. Standard Resistor Values
  2. Standard Electronic Decade Value Tables ... (Oct 4, 2006)
  3. Standard Resistor Values
  4. Precision Decade Resistor
  5. 2.2 Preferred Resistor Values
  6. STANDARD SERIES OF VALUES IN A DECADE FOR RESISTORS AND ...
  7. Standard Electronic Decade Values Table - Vishay Dale

Need to source matching manufacturers or get a quote?

SpecForge connects industrial buyers with verified manufacturers. Submit your requirement and we will route it to matched suppliers.

Submit RFQ now →
Ask SpecForge AI