Cable Gland manufacturer profile

icotek GmbH & Co. KG

icotek GmbH & Co. KG is a cable gland manufacturer based in Eschach, Germany. [S2][S1]

Country
Germany [S1]
City
Eschach [S2]
Website
icotek.com

Procurement snapshot

Only hard product-level facts retained from the cited source route are shown below. A missing buying field is handled separately, rather than estimated from the listed series.

Entry protection
Split cable-entry system with IP66 and UL Type 12/4X ratings. [S4]
Grommet range
KT 1–15 for 1–16 mm and KTG 13–KT34 for 13–35 mm. [S5]
KEL-ER cable entry system
Official product image [S12]

Evidence scope

The retained official product route documents: icotek documents KEL-ER as a split cable-entry system for pre-terminated cables. This dossier uses that cited route as the editorial scope. [S7]

The retained research coverage separates company identity from the named product evidence. It does not turn one model or series into a claim about unlisted company-wide operations. [S9]

Cable Gland

Documented series: KEL-ER split cable-entry systems for pre-terminated cables.

icotek documents KEL-ER as a split cable-entry system for pre-terminated cables. [S7]

Documented specifications for Cable Gland
StandardEN 62444 [S10]
Flame / recognitionUL recognized [S11]
Entry protection
Split cable-entry system with IP66 and UL Type 12/4X ratings. [S4]
Grommet range
KT 1–15 for 1–16 mm and KTG 13–KT34 for 13–35 mm. [S5]
  • KEL-ER split cable-entry systems for pre-terminated cables. [S6]

Selection fit: Compare KEL-ER when pre-terminated cables require a split cable-entry frame and the cited IP66/UL boundary; confirm frame and grommet sizing with icotek. [S8]

Product range and documented series

icotek documents KEL-ER as a split cable-entry system for pre-terminated cables. [S7]

  • KEL-ER split cable-entry systems for pre-terminated cables. [S6]Source note: cables with connectors

Procurement fit

Procurement evaluation should compare the KEL-ER split cable-entry frame against application requirements for pre-terminated cables, verifying the cited IP66 ingress rating and UL Type 12/4X boundary against the target enclosure standard. Specifiers must confirm frame dimensions, grommet selection from the KT 1–15 or KTG 13–KT34 families, and overall assembly fit with icotek prior to release, since the public record does not enumerate installation torque, panel cutout tolerances, or accessory hardware.

Technical capabilities

The KEL-ER split cable-entry system carries an IP66 ingress protection rating, is qualified to EN 45545, and is offered in a 46 × 46 mm section size with stainless steel construction. Entry protection is documented at IP66 and UL Type 12/4X. Grommets span two ranges: the KT 1–15 family covering 1–16 mm cable diameters and the KTG 13–KT34 family covering 13–35 mm. The system accommodates pre-terminated cables through a split-frame architecture.

Markets and applications

The KEL-ER system is documented for pre-terminated cable entry into enclosures. The EN 45545 standard reference points to fire-protection requirements in rolling stock and rail vehicle applications, although specific end-user sectors, geographies, and installed base figures are not publicly documented. Use cases implied by the documentation include control cabinets, power distribution panels, and rolling stock electronics where connectorized cables must pass through enclosure walls without disconnection.

Evidence limitations

The following procurement fields are not publicly documented: lead times, minimum order quantities, unit pricing, full bill of materials for the KEL-ER frame, installation torque values, panel cutout drawings beyond the 46 × 46 mm section size, country of origin for raw stainless stock, full certification scope beyond EN 45545, RoHS and REACH status, and authorized distributor list. Buyers should request these items directly from icotek.

Editorial summary

icotek GmbH & Co. KG, based in Eschach, Germany, supplies cable gland products, with documented focus on the KEL-ER split cable-entry system for pre-terminated cables. The product category centers on frames and grommets designed for enclosure wall entry where cable terminations cannot be disrupted. Public documentation for this manufacturer is limited to the KEL-ER series and its associated grommet families, with no additional categories listed in the current specification record.

Compiled prose, not a quotation. It restates facts drawn from the cited rows above and adds none of its own. It is not itself a sourced record, so read the cited sections for the authoritative wording.

Not published in retained sources

These common buyer fields were explicitly outside the retained source coverage for this dossier. They are shown as omissions, not filled with a proxy, a related model or an assumption.

  • Annual sales [S9]
  • Production capacity [S9]
Research coverage

Evidence states describe the public material reviewed for this profile; they do not rate the company or assert an undisclosed fact.

  • icotek corporate context is retained from its legal notice. KEL-ER facts and visual are limited to the cited cable-entry system and are not rewritten as a conventional single-hole gland; no wider product, capacity or sales claim is asserted. [S9]Company-stated

Frequently asked questions

What Cable Gland product is documented for icotek GmbH & Co. KG?

The retained product material names KEL-ER split cable-entry systems for pre-terminated cables. The dossier keeps this as a product-level statement rather than using it as a claim about the company's entire catalogue. [S6]

Which published entry protection should a buyer compare?

The cited product material records: Split cable-entry system with IP66 and UL Type 12/4X ratings. Use the value as a product-level comparison point, while keeping the exact model and installation boundaries in the cited route. [S4]

Which published grommet range should a buyer compare?

The cited product material records: KT 1–15 for 1–16 mm and KTG 13–KT34 for 13–35 mm. Use the value as a product-level comparison point, while keeping the exact model and installation boundaries in the cited route. [S5]

Which common buying fields are not published in the retained sources?

The retained source packet does not publish Annual sales, Production capacity. Those fields are intentionally left out of the procurement snapshot rather than inferred from a related series, a product image or the company identity. [S9]

Research notes