Pt100 0.00385 vs 0.00392 Curve Difference

A Pt100 calibrated to alpha 0.00385 has a nominal resistance of 100.00 Ω at 0°C and a 0.00385 Ω/Ω/°C average temperature coefficient, while the 0.00392 curve uses a slightly steeper resistance-temperature relationship [S1][S3].

The choice is not a change in nominal sensor resistance: both curves represent Pt100 elements at 100.00 Ω at 0°C, but the transmitter's curve conversion must match the sensor specification or the displayed temperature will carry a systematic error [S2][S3].

What Alpha Changes in a Pt100

The alpha coefficient defines the average fractional resistance change per degree Celsius between 0°C and 100°C. For a nominal Pt100, this is 0.00385 Ω/Ω/°C or 0.00392 Ω/Ω/°C, and the higher value creates a slightly larger resistance change for the same temperature rise [S3].

Both curves share the same anchor at 0°C: 100.00 Ω. They diverge as temperature departs from that point because the 0.00392 curve assumes a steeper response than the 0.00385 curve. The difference is therefore small near 0°C but increases with distance from the reference point [S1][S2].

IEC 60751:2022 was used as the basis for editing the Pt100 tolerance classes.

Measurement Error From a Mismatched Curve

This error persists even when the sensor measures resistance correctly. A calibration check at 0°C can conceal the problem because both curves are based on 100.00 Ω at that temperature; the mismatch becomes more apparent at elevated process temperatures [S1][S3].

Curve mismatch should be treated separately from Pt100 accuracy class. Tolerance limits describe how closely a compliant sensor follows its specified curve, while the alpha setting determines which curve the transmitter uses to convert resistance into temperature [S1].

0.00385, 0.00392 and 0.003916 Compared

what is the difference between Pt100 alpha 0.00385 and 0.00392 curves? - 0.00385, 0.00392 and 0.003916 Compared
what is the difference between Pt100 alpha 0.00385 and 0.00392 curves? - 0.00385, 0.00392 and 0.003916 Compared

The principal selection decision is the curve supported by the measuring equipment, not a preference between identical sensors. The table below compares the three industrial alpha values identified in the research material [S2][S3].

None of the three labels should be inferred from the “Pt100” name alone [S3].

Selecting a Replacement Pt100 Sensor

A replacement Pt100 is suitable when its stated alpha matches the transmitter configuration and the existing installation requirement. The sensor datasheet, terminal label, transmitter menu and calibration record should be checked because “Pt100” alone specifies the 0°C resistance, not the resistance-temperature curve [S1][S3].

For an existing 0.00392 installation, matching the established curve may avoid recalibration of the transmitter and prevent a shift in the process reading [S2][S3].

Lead arrangement does not change the alpha difference, but it affects the resistance actually measured. A 2-wire connection adds lead resistance directly, while 3-wire and 4-wire arrangements compensate for it.

Where the Difference Matters in Service

what is the difference between Pt100 alpha 0.00385 and 0.00392 curves? - Where the Difference Matters in Service
what is the difference between Pt100 alpha 0.00385 and 0.00392 curves? - Where the Difference Matters in Service

It is less consequential where the process tolerance comfortably exceeds the curve-induced offset, although the display still differs from the correct temperature [S2].

RTDs are used across roughly -200°C to 850°C where stable accuracy and long-term resistance behaviour are more important than fast response. Platinum elements provide a repeatable resistance-temperature relationship, and a transmitter applies a conversion such as the Callendar-Van Dusen equation to derive temperature [S3].

For precision transfer work, the sensor tolerance, calibration uncertainty, wiring method and alpha setting must be evaluated together. The guidance on Pt100 Class A vs Class B tolerance selection separates the accuracy-class decision from curve selection, while the Pt100 RTD overview covers the resistance-measurement principle.

Verification and Commissioning Checks

A three-point check at 0°C, 100°C and an elevated operating temperature will expose a systematic curve mismatch more effectively than a single-point resistance check. Both curves meet at 100.00 Ω at 0°C, but their predicted resistances diverge as temperature rises [S1][S3].

Record the sensor alpha, transmitter alpha setting, excitation current, wiring configuration and measured resistance separately. The excitation current must be controlled because self-heating changes the element resistance and adds an error to any curve comparison [S1].

Do not treat the Pt100 or Pt1000 suffix as a substitute for alpha information. A Pt1000 has 1000.00 Ω at 0°C and provides ten times the resistance change per degree of a Pt100 at the same current, but it still requires an explicitly supported resistance-temperature conversion [S3].

The first actionable check is to read the alpha marking on the installed sensor or its datasheet and compare it with the transmitter's Pt100 curve setting. If the sensor is marked 0.00385, configure 0.00385; if it is marked 0.00392, confirm that the transmitter supports 0.00392 or supply a matching transmitter before recalibration [S2][S3].

Frequently asked questions

What temperature error occurs when a 0.00392 Pt100 is read with a transmitter set to alpha 0.00385?

Using the 0.00385 conversion for a sensor specified for the 0.00392 curve can produce a temperature-reading error because the two alpha values describe different resistance-temperature relationships.

Which Pt100 alpha curve should be selected for a new industrial installation?

IEC 60751:2022 was used as the basis for editing the Pt100 tolerance classes, but the supplied sources do not establish that it specifies the 0.00385 curve or that this curve is the global industrial standard for Pt100 RTDs. The 0.00392 curve is mainly relevant to legacy American instrumentation.

How can I verify whether a Pt100 uses the 0.00385 or 0.00392 curve?

Check the sensor datasheet, terminal label, transmitter menu and calibration record, then perform a three-point check at 0°C, 100°C and an elevated operating temperature. A check only at 0°C may conceal the mismatch because both curves are anchored at 100.00 Ω.

Does replacing a Pt100 sensor require changing its nominal resistance from 100.00 Ω?

No. Both 0.00385 and 0.00392 curves represent Pt100 sensors with a nominal resistance of 100.00 Ω at 0°C. The replacement must match the transmitter’s configured alpha curve, while Pt1000 is a different option with 1000.00 Ω at 0°C.

3 sources
  1. Pt100 temperature sensor – useful things to know (Apr 17, 2018)
  2. Wiring a 4-Wire PT100 RTD to a 3-Wire Transducer Converter (2026/07/31 00:00:00)
  3. How an RTD PT100 Works: Industrial Temperature Measurement

Need to source matching manufacturers or get a quote?

SpecForge connects industrial buyers with verified manufacturers. Submit your requirement and we will route it to matched suppliers.

Submit RFQ now →
Ask SpecForge AI