Choose proximity probes for relative shaft displacement and absolute shaft vibration limits, and use seismic sensors for casing vibration. The sensor choice depends on whether the diagnostic objective is bearing clearance, rotor stress, or machine-structure response.
Relative shaft vibration is measured between the shaft and bearing, absolute shaft vibration describes shaft motion relative to the machine, and seismic vibration is measured on the casing. Each quantity answers a different engineering question and cannot be substituted without knowing the measurement geometry and bearing arrangement.
Measurement Definitions and Decision Boundaries
Relative shaft vibration is the dynamic motion of the shaft relative to its bearing. A proximity probe establishes a non-contact measurement against the conductive shaft surface, and paired probes can measure shaft centerline position and the displacement orbit [S4][S5].
Absolute shaft vibration describes shaft motion relative to a fixed machine reference and is associated with the forces acting on the rotor and its supports. The distinction is practical: absolute shaft vibration provides an indication of shaft stress, while relative shaft vibration indicates how much journal-bearing clearance the vibration consumes and how that motion loads the Babbitt bearing liner [S2].
Seismic vibration is casing vibration measured with an accelerometer, velocity sensor, or other casing-mounted transducer. It is the machine-structure response, not a direct displacement measurement of the shaft [S1][S7].
These terms also govern phase interpretation. Relative phase is reported over -180° to 180°, whereas absolute phase is reported over 0° to 360° [S1]. Analysts should not compare phase conventions without confirming the reference channel, because shaft proximity measurements and casing measurements use different physical references.
Sensor Selection by Measurement Objective
Proximity probes are the preferred direct measurement for relative shaft displacement on fluid-film-bearing turbomachinery. They provide non-contact sensing and can be installed in pairs to define shaft centerline and orbit [S4][S5].
Seismic sensors are the practical choice for absolute casing vibration. Accelerometers and velocity sensors mount directly on the machine and capture structural vibration over a broad operating band.
For an installed machine requiring both shaft-specific and structure-specific information, the relevant reference devices are a proximity probe for relative displacement and a seismic sensor for casing response. A vibration analyzer should support frequency, amplitude, and phase analysis rather than merely display a raw trend.
Absolute Shaft Measurement Requires Two Directions

Absolute shaft vibration is not the same as relative shaft vibration plus one arbitrary casing value. In dual X-Y measurement arrangements, casing vibration and relative shaft vibration are combined to identify absolute shaft vibration [S3]. The calculation must use the established measurement geometry and phase relationships; adding amplitudes without phase produces an incorrect vector result.
Absolute shaft vibration measurement is normally associated with fluid-film sleeve-bearing arrangements. Its engineering value is that it represents shaft motion at the rotor level, whereas relative shaft vibration is primarily a bearing-clearance measurement [S2][S6]. This makes absolute shaft data more suitable for evaluating rotor stress, and relative shaft data more suitable for evaluating bearing-liner loading and proximity to contact.
The casing must be treated as a moving reference when casing motion is significant. A high-amplitude seismic reading can therefore reduce the apparent rotor motion relative to the machine structure even while bearing-relative shaft motion increases. If the objective is to separate those effects, install proportional X-Y probes at the measurement location and pair them with casing and speed reference channels.
Direction coverage is part of the specification. X-Y probes characterize the transverse orbit, while radial and axial probe pairs address different shaft-motion planes. Machine drawings, bearing geometry, probe orientation, keyway and seam locations, and electrical calibration records must be retained because these details determine how the final shaft-relative and shaft-absolute values are derived.
Relative Shaft Limits and Bearing Behavior
Relative shaft displacement is constrained by the physical bearing clearance. A shaft cannot move farther, peak-to-peak, than the available diametral clearance before metal-to-metal contact occurs. Consequently, a proximity reading is a bearing-health measurement and does not, by itself, quantify the force transmitted through the bearing [S5].
As shaft vibration grows and the journal eccentricity ratio increases, fluid-film behavior changes materially. Bearing stiffness and damping are minimum near zero eccentricity and remain approximately constant over low eccentricity ratios. As eccentricity approaches 1, stiffness and damping rise sharply, while the circumferential average fluid-velocity ratio, λ, behaves in the opposite way [S5]. This nonlinear behavior explains why a small increase in relative shaft motion can become operationally significant near the bearing-clearance limit.
Proximity systems also have application constraints. Probe material compatibility, probe-to-demodulator cable length, and probe construction affect performance, while the shaft target should provide a clean, conductive measuring surface [S4]. Calibration should verify both static position and dynamic response rather than accepting the displayed amplitude without checking the installation record.
Proximity measurement offers a flat DC frequency response up to 10 kHz in the cited turbomachinery application and supports simple calibration [S5]. That characteristic makes it well suited to shaft protection and acceptance testing, but it does not remove the need to check the machine-specific bearing clearance and protection limits.
Application Recommendations by Machine

For a compressor, turbine, generator, or motor with fluid-film bearings, specify non-contact relative shaft probes when the objective is bearing clearance, shaft orbit, or machine protection. The cited turbomachinery practice uses proximity probes for acceptance testing and protection, particularly where rotor support behavior and journal clearance are the decision variables [S5].
For general rotating equipment without direct shaft-probe access, specify seismic velocity or acceleration measurements for casing condition and fault diagnosis. This approach is appropriate for imbalance, misalignment, looseness, bearing, gear, and blade-related vibration signatures because vibration amplitude, frequency, and phase remain central diagnostic variables [S1].
For critical machines requiring both rotor-force evaluation and bearing monitoring, use a combined architecture: proportional X-Y shaft probes, casing channels in corresponding axes, and a once-per-revolution speed reference. A dual-probe arrangement can identify the shaft centerline, orbit, and absolute shaft motion from the relative and casing measurements [S3][S5].
Do not use a casing alarm as a substitute for a shaft-relative protection limit, or a proximity alarm as a substitute for a casing-vibration trend. The two measurements have different reference frames and failure implications. This distinction is particularly important on machines with heavy casings, fluid-filled bearings, or high rotational speed, where indirect pedestal movement may not accurately represent direct shaft behavior [S2].
Installation, Calibration, and Failure Modes
Seismic sensor mounting determines frequency response and repeatability. The transducer, mounting surface, adhesive or stud, orientation, cable routing, and surface preparation all affect the path from casing motion to the instrument. A sensor with a valid calibration certificate can still produce misleading data if the mounting interface is weak, uneven, or contaminated. [S1]
Proximity probes require attention to target material, stand-off, sensitivity, cable length, and demodulator configuration [S4]. A shaft surface with a seam, keyway, hard-facing, or localized damage can distort the local target. Two probes installed at nominally orthogonal locations should be checked for directional sensitivity and phase response before an orbit calculation is accepted.
Absolute shaft calculations also fail when phase references are mixed, sensor polarity is reversed, or casing and shaft axes are not geometrically aligned. Machine dynamics can also affect the result: the rotor, bearings, foundation, and casing act as a coupled structural system, not as independent components [S5].
For procurement and acceptance, retain the measurement definition, sensor model, serial number, calibration date, mounting axis, probe gap, cable configuration, machine speed range, operating temperature, and applicable alarm or trip settings. Those records make a relative shaft trend, casing trend, or absolute shaft calculation reproducible and auditable.
Standards and Interpretation Boundaries

Shaft-vibration specifications must distinguish the measurement quantity before acceptance limits are compared. The Vibration Institute identifies ISO 7919, API methods, the Eshleman/Sohre relative-and-absolute methods, the Dresser-Clark method, and the McHugh method as shaft-vibration specification approaches [S2]. These systems are not interchangeable simply because they appear on the same datasheet.
ISO 7919 is used within the cited shaft-vibration standards material, while API measurement requirements have included relative displacement for centrifugal-compressor acceptance testing since 1970 [S2][S5]. The governing document and edition must be checked against machine type, bearing construction, probe arrangement, and speed before applying numerical limits.
Seismic and casing measurements also require their own specification basis. ISO 10816-series vibration evaluation and ISO 20816-series are associated with machine vibration assessment, but the supplied material does not establish a specific edition or numerical acceptance limit for an application [S1][S2]. No threshold should be assigned to a named standard without the applicable edition and machine classification.
For phase and signal processing, preserve the distinction between relative phase from -180° to 180° and absolute phase from 0° to 360° [S1]. For sensor selection, keep the cited operating limits in view: approximately 10 kHz flat DC response for the referenced proximity system, below 120°C for typical piezoelectric seismic instruments, and up to approximately 375°C for the referenced moving-coil velocity sensor [S4][S5].
The next procurement decision is specific: identify whether protection requires a shaft-relative limit, a casing alarm, or a calculated absolute-shaft limit; then freeze the sensor axes, reference channels, calibration method, and governing specification before approving the instrumentation package.