When to Use Double Wall Double Image Radiography

Table of Contents
  1. Why DWSI Becomes Inefficient on Small Pipe
  2. Dimension Limits for Selecting DWDI
  3. Elliptical Versus Perpendicular DWDI
  4. Decision Criteria Across Radiographic Techniques
  5. Image Quality and Acceptance Controls
  6. Where DWDI Is the Wrong Choice
When to Use Double Wall Double Image Radiography

Double wall, double image (DWDI) radiography is generally selected for small-diameter pipe welds below about 75–80 mm diameter, where double wall, single image (DWSI) would require an impractical number of exposures [S1][S3].

The method places both pipe walls in one exposure and interprets the source-side and film-side weld images separately, making it suitable for small pipe, elliptical welds, offset welds and inaccessible weld geometry [S2][S3].

Why DWSI Becomes Inefficient on Small Pipe

For pipe welds, single wall, single image is normally the first technique, followed by double wall, single image when the first is not feasible [S3]. On small-diameter pipe, DWSI becomes inefficient because its effective film length is limited, forcing a disproportionate number of exposures [S3].

That exposure penalty matters where the complete circumference requires examination. DWDI instead captures both sides of the pipe in a single exposure, and both the source-side and film-side welds are evaluated [S3]. The change is driven by geometry and exposure coverage, not by a universal preference for one radiographic arrangement.

ISO 20769-2 identifies the double-wall pipe-inspection standard and applies to both film and digital radiography [S4].

Dimension Limits for Selecting DWDI

Typical DWDI limits are external diameter below 75 mm and wall thickness below 8 mm, while some technical guidance gives a practical upper diameter near 80 mm [S1][S3]. These dimensions fit the small-pipe application where DWSI requires too many exposures [S1][S3].

DWDI also suits elliptical or offset welds because the technique captures images of both walls for interpretation [S2]. It is not limited to straight, concentric welds, but the source and detector positions must be calculated so the two weld images can be distinguished. The required source offset places the source-side and film-side images approximately one weld width apart on the detector [S3].

A further constraint is weld width. The elliptical DWDI configuration calls for weld width below De/4, where De is external diameter [S3]. The ratio t/De then determines the number of exposures required for full coverage [S3].

Elliptical Versus Perpendicular DWDI

when should double wall double image be used instead of double wall single image? - Elliptical Versus Perpendicular DWDI
when should double wall double image be used instead of double wall single image? - Elliptical Versus Perpendicular DWDI

Elliptical DWDI is preferred when external diameter is below 100 mm, practical pipe size is about 75 mm, wall thickness is below 8 mm and weld width is below De/4 [S3]. If t/De is below 0.12, two images rotated 90° relative to each other provide 100% coverage; if t/De is 0.12 or greater, three exposures at 60° or 120° intervals provide full examination [S3].

Perpendicular DWDI is the alternative when elliptical imaging is impractical, including bends, varying wall thickness or difficult access [S3]. Its full weld coverage uses three exposures spaced evenly around the pipe [S3]. Compared with elliptical DWDI, perpendicular DWDI solves geometry and access problems but still requires three positions rather than the possible two-position elliptical sequence.

Radiographic procedure selection must therefore compare exposure count, detector placement, source offset and image separation. For thicker-walled small pipe, t/De of at least 0.12 pushes elliptical DWDI from two exposures to three, while bends or uneven walls can make the perpendicular arrangement the practical choice [S3].

Decision Criteria Across Radiographic Techniques

SW-SI has the simplest source-to-detector arrangement and remains the normal starting point for pipe welds [S3]. DWSI places both walls on one image and can increase usable coverage, but the number of exposures becomes disproportionate on small pipe [S3][S4]. DWDI gives separate source-side and film-side weld images in one exposure and is normally limited to small diameters and walls below 8 mm [S1][S3].

The comparison is straightforward: use SW-SI when its geometry is workable, DWSI when one combined image is useful and full coverage remains practical, and DWDI when small-diameter geometry makes DWSI exposure counts excessive [S3]. DWDI is less suitable when its dimensional or weld-width limits are exceeded, or when access prevents reproducible elliptical and perpendicular placements [S3].

For other cylindrical components, the decision cannot be transferred from pipe welds without qualification. ISO 20769-1 covers tangential radiography, while ISO 20769-2 covers the double-wall technique and applies to cylindrical bodies including tubes, boiler drums, penstocks and pressure vessels [S4]. Those standards identify separate technical routes rather than making DWDI a universal replacement for every pipe arrangement [S4].

Image Quality and Acceptance Controls

when should double wall double image be used instead of double wall single image? - Image Quality and Acceptance Controls
when should double wall double image be used instead of double wall single image? - Image Quality and Acceptance Controls

Radiographic quality is evaluated through density, contrast and definition or sharpness, with sensitivity measured using an image quality indicator (IQI) [S1]. Wire-type IQIs under EN ISO 19232-1 or ASTM E747 use wire diameters from 1–8 mm and lengths from 10–50 mm in iron, nickel, aluminium, magnesium, copper or titanium [S1].

The IQI is selected according to the metal type and component thickness, and its sheath carries identification that is generally visible on the radiograph [S1].

Interpretation requires trained radiographers familiar with welding processes, joint design, radiographic technique and relevant imperfections, with many specifications requiring independent certification such as PCN or CSWIP [S1]. Film processing also affects the result: chemicals must be at the correct concentrations and temperature, drying must not leave stains, and viewing requires controlled screen luminance appropriate to image density [S1].

Where DWDI Is the Wrong Choice

DWDI is not the preferred technique for every pipe weld or every cylindrical component [S3]. Its practical envelope is narrow: the material notes diameters below 75–80 mm, while the more specific elliptical procedure uses wall thickness below 8 mm and weld width below De/4 [S1][S3].

The method also introduces setup sensitivity. The source-side and film-side images must be separated through calculated source offset, and the two images should be approximately one weld width apart [S3]. Incorrect offset can cause overlap, inadequate separation or unclear visualization, undermining interpretation of both weld images [S3].

For larger pipe, SW-SI or DWSI should be evaluated before accepting the additional positioning work of DWDI. For bends, unequal wall thickness or restricted access, perpendicular DWDI may be necessary, but each configuration still requires calculated exposure geometry and documented coverage [S3].

The practical trigger is therefore not simply “two walls.” It is the combination of small pipe diameter, limited film length, excessive DWSI exposure demand and a weld geometry that permits two or three controlled DWDI positions [S1][S3].

Track the selected technique against pipe De, wall thickness t, weld width, t/De and the required exposure count. Any move from DWSI to DWDI should also record the source offset, image separation and full-circumference coverage, with ISO 20769-2 providing the double-wall reference for cylindrical inspection applications [S3][S4].

Frequently asked questions

When should double wall double image radiography be selected instead of double wall single image for a pipe weld?

Select DWDI when small-diameter geometry makes DWSI require an impractically large number of exposures. It is typically used below about 75–80 mm external diameter and below 8 mm wall thickness, provided full coverage remains practical.

What dimensional and weld-width limits apply to elliptical double wall double image radiography?

Elliptical DWDI is preferred below 100 mm external diameter, with practical pipe size around 75 mm, wall thickness below 8 mm, and weld width below De/4, where De is the external diameter. It also suits elliptical or offset welds when source and detector positions allow the two weld images to be distinguished.

How many exposures are required for full elliptical DWDI coverage as pipe wall thickness increases?

When t/De is below 0.12, two images rotated 90° provide 100% coverage. When t/De is 0.12 or greater, three exposures at 60° or 120° intervals are required for full examination.

When is perpendicular DWDI preferable to elliptical DWDI?

Use perpendicular DWDI when elliptical imaging is impractical because of bends, varying wall thickness, or difficult access. Its full-coverage sequence uses three exposures spaced evenly around the pipe, compared with the possible two-exposure elliptical sequence.

5 sources
  1. Radiography Part 2 - TWI
  2. Radiographic Techniques for Weld Inspection Study Guide (Oct 12, 2024)
  3. Radiographic Techniques for Small Diameter Pipe Welds