Manufacturer profile

Cicoil, LLC

Cicoil, LLC is a manufacturer based in Valencia, United States. [S2][S1]

Country
United States [S1]
City
Valencia [S2]
Website
cicoil.com

Procurement snapshot

Only hard product-level facts retained from the cited source route are shown below. A missing buying field is handled separately, rather than estimated from the listed series.

Flex life
Nominal flex life of 10,000,000 cycles. [S4]
Conductor and bend range
4 to 28 AWG, 2 to 12 conductors, with continuous-motion bend radii from 0.8 to 4.7 inches. [S5]
unshielded high-flex flat cable
Official product image [S17]

Evidence scope

The retained official product route documents: Cicoil documents an unshielded high-flex flat-cable range for repeated continuous-motion applications. This dossier uses that cited route as the editorial scope. [S6]

The retained research coverage separates company identity from the named product evidence. It does not turn one model or series into a claim about unlisted company-wide operations. [S9]

Drag Chain Cable

Documented series: Cicoil unshielded high-flex flat cable.

Cicoil documents an unshielded high-flex flat-cable range for repeated continuous-motion applications. [S6]

Documented specifications for Drag Chain Cable
Service temperature-104°C [S10]
Flex life
Nominal flex life of 10,000,000 cycles. [S4]
Conductor and bend range
4 to 28 AWG, 2 to 12 conductors, with continuous-motion bend radii from 0.8 to 4.7 inches. [S5]
  • Cicoil unshielded high-flex flat cable. [S6]

Selection fit: Compare by conductor gauge and count, overall flat-cable geometry, bend radius and target cycle life; verify the exact configuration rather than the family heading. [S8]

Shielded Cable

Documented series: Cicoil Shielded Signal High Flex Cable

Cicoil documents a shielded signal flat-cable family for continuous high-flex motion. [S7]

Documented specifications for Shielded Cable
Service temperature-104°C [S15]
Flame / recognitionUL 94V-0 [S16]
Shield and cycle rating
The page specifies twisted shielded signal pairs for EMI/RFI protection and a nominal 10,000,000-cycle flex life. [S11]
Continuous-motion bend radius
It lists continuous-motion bend-radius options from 1.2 to 2.1 inches. [S12]
  • Cicoil Shielded Signal High Flex Cable [S7]

Selection fit: Compare pair count, EMI/RFI requirement, bend radius and continuous-flex motion envelope before selection. [S13]

Product range and documented series

Cicoil documents an unshielded high-flex flat-cable range for repeated continuous-motion applications. [S6]

  • Cicoil unshielded high-flex flat cable. [S6]Source note: Unshielded High Flex Cable
  • Cicoil Shielded Signal High Flex Cable [S7]Source note: Cicoil Shielded Signal High Flex Cable

Procurement fit

Specifiers should evaluate each series against the geometry and motion envelope of the intended cable carrier rather than the family heading alone. For the unshielded high-flex flat cable, the documented comparison drivers are conductor gauge and count, flat-cable geometry, continuous-motion bend radius, and target cycle life. For the Shielded Signal High Flex Cable, the documented comparison drivers are pair count, EMI/RFI requirement, bend radius, and the continuous-flex motion envelope. The manufacturer record advises verifying the exact configuration rather than relying on the family heading before release to procurement.

Technical capabilities

The unshielded high-flex flat cable series covers 4 to 28 AWG with 2 to 12 conductors and continuous-motion bend radii from 0.8 to 4.7 inches, with a nominal 10,000,000-cycle flex life. The Shielded Signal High Flex Cable series uses twisted shielded signal pairs for EMI/RFI protection, offers continuous-motion bend-radius options from 1.2 to 2.1 inches, and carries the same nominal 10,000,000-cycle flex life rating. The numeric values cited here are reproduced from the documented specifications without extrapolation, derivation, or rounding.

Markets and applications

Both documented series target continuous-motion industrial applications requiring long flex service, such as cable carriers and moving machine subsystems. The unshielded high-flex flat cable fits general motion duty where EMI/RFI shielding is not the primary constraint, while the Shielded Signal High Flex Cable addresses signal integrity in electrically noisy environments through twisted shielded pairs. End-market segmentation by vertical industry, installed base data, and application case studies are not publicly documented for either series in the available specification record.

Evidence limitations

Several common specification and procurement fields are not publicly documented in the available record. Operating temperature range, voltage rating, current rating, jacket material, agency listings, and compliance certifications are not publicly documented for either series. Bend radius resolution finer than the documented 1.2 to 2.1 inch range for the shielded series is not publicly documented. Customer references, production lead time, minimum order quantity, and pricing tier information are not publicly documented.

Editorial summary

Cicoil, LLC is a United States based cable manufacturer located in Valencia with documented offerings in two industrial cable categories: drag chain cable and shielded cable. The drag chain product is identified as the Cicoil unshielded high-flex flat cable series, while the shielded offering is the Cicoil Shielded Signal High Flex Cable. Both product lines are rated for continuous motion service and share a nominal flex life of 10,000,000 cycles. Specifications below are limited to what the manufacturer documentation publicly discloses for each series.

Compiled prose, not a quotation. It restates facts drawn from the cited rows above and adds none of its own. It is not itself a sourced record, so read the cited sections for the authoritative wording.

Not published in retained sources

These common buyer fields were explicitly outside the retained source coverage for this dossier. They are shown as omissions, not filled with a proxy, a related model or an assumption.

Research coverage

Evidence states describe the public material reviewed for this profile; they do not rate the company or assert an undisclosed fact.

  • Identity and location are retained from the official certificate. Product facts and visual are limited to the cited unshielded high-flex family. [S9]Company-stated
  • Identity and location are retained from the cited official source. Product facts and visual are limited to Cicoil Shielded Signal High Flex Cable; no unlisted company-wide performance, availability, factory or revenue claim is asserted. [S14]Company-stated

Frequently asked questions

What Drag Chain Cable product is documented for Cicoil, LLC?

The retained product material names Cicoil unshielded high-flex flat cable. The dossier keeps this as a product-level statement rather than using it as a claim about the company's entire catalogue. [S6]

Which published flex life should a buyer compare?

The cited product material records: Nominal flex life of 10,000,000 cycles. Use the value as a product-level comparison point, while keeping the exact model and installation boundaries in the cited route. [S4]

Which published conductor and bend range should a buyer compare?

The cited product material records: 4 to 28 AWG, 2 to 12 conductors, with continuous-motion bend radii from 0.8 to 4.7 inches. Use the value as a product-level comparison point, while keeping the exact model and installation boundaries in the cited route. [S5]

Which common buying fields are not published in the retained sources?

The retained source packet does not publish Annual sales, Availability or stock. Those fields are intentionally left out of the procurement snapshot rather than inferred from a related series, a product image or the company identity. [S9][S14]

Research notes

The retained first-party packet supports a richer product-level reading surface, but it does not yet contain 600 words of distinct cited content. This noindex dossier remains in reviewing status until additional source-backed facts are retained.