Manufacturer profile
Eland Cables Limited
Eland Cables Limited is a manufacturer based in London, United Kingdom. [S2][S1]
- Country
- United Kingdom [S1]
- City
- London [S2]
- Website
- elandcables.com
Procurement snapshot
Only hard product-level facts retained from the cited source route are shown below. A missing buying field is handled separately, rather than estimated from the listed series.
Evidence scope
The retained official product route documents: Eland Cables documents Powerchain as a highly flexible control-cable family for drag-chain applications. This dossier uses that cited route as the editorial scope. [S8]
The retained research coverage separates company identity from the named product evidence. It does not turn one model or series into a claim about unlisted company-wide operations. [S10]
Drag Chain Cable
Documented series: Eland Powerchain drag-chain control cables.
Eland Cables documents Powerchain as a highly flexible control-cable family for drag-chain applications. [S8]
| Standard | EN 60811-404 [S11] |
|---|
- Rating and conductor
- 300/500 V with Class 6 extra-flexible copper conductors. [S4]
- Sheath and screening
- PUR or PVC sheath options; screened CY/CP variants use tinned-copper braid. [S5]
- Eland Powerchain drag-chain control cables. [S6]
Selection fit: Compare Powerchain by sheath material, screened or unscreened construction, conductor arrangement and the actual drag-chain movement envelope. [S9]
Power Cable
Documented series: Eland N2XSY copper-conductor medium-voltage cable
Eland Cables documents N2XSY as a single-core copper-conductor medium-voltage power-cable family. [S7]
- Voltage variants
- The cited page lists 6/10 kV, 12/20 kV and 18/30 kV variants. [S12]
- Construction
- It specifies a stranded Class 2 copper conductor with XLPE insulation and a PVC oversheath. [S13]
- Eland N2XSY copper-conductor medium-voltage cable [S7]
Selection fit: Compare voltage grade, conductor cross-section, installation environment and IEC 60502-2 requirements before selection. [S14]
Product range and documented series
Eland Cables documents Powerchain as a highly flexible control-cable family for drag-chain applications. [S8]
Procurement fit
Selection should follow the category-specific comparison points listed in the documentation. For Eland Powerchain drag-chain control cables, buyers are directed to compare sheath material, screened or unscreened construction, conductor arrangement, and the actual drag-chain movement envelope. For Eland N2XSY medium-voltage cable, the documented procurement criteria are voltage grade, conductor cross-section, installation environment, and IEC 60502-2 requirements prior to order placement.
Technical capabilities
Eland Powerchain drag-chain control cables are rated at 300/500 V and use Class 6 extra-flexible copper conductors in a halogen-free construction. Sheath options are PUR or PVC, and the screened CY/CP variants employ tinned-copper braid. The Eland N2XSY medium-voltage cable is supplied in 6/10 kV, 12/20 kV and 18/30 kV variants, built around a stranded Class 2 copper conductor with XLPE insulation and a PVC oversheath. Both product lines reference IEC 17025.
Markets and applications
The documented cable categories indicate two distinct application fields. Eland Powerchain drag-chain control cables are specified for installations where continuous flexing within a defined movement envelope is required, consistent with their 300/500 V control rating and Class 6 flexible conductor design. Eland N2XSY medium-voltage cable is specified for fixed power distribution at 6/10 kV, 12/20 kV or 18/30 kV using XLPE insulation. Specific end-use sectors and named reference projects are not publicly documented.
Evidence limitations
The following items commonly expected in a procurement profile are not publicly documented: company size, manufacturing capacity, quality system certifications beyond IEC 17025, specific customer references, lead times, distributor network details, and third-party approvals such as UL, CSA, or BASEC. Compliance with IEC 60502-2 is referenced for procurement comparison of the N2XSY range but is not listed as a product certification. No recent market signals were available at the time of compilation.
Editorial summary
Eland Cables Limited is a United Kingdom based cable manufacturer with operations referenced from a London office. The documented product range comprises two principal categories: drag chain cable and power cable. The drag chain offering is centred on the Eland Powerchain series of halogen-free control cables, while the power cable offering covers the Eland N2XSY medium-voltage family. Both categories are referenced against IEC 17025 in the source documentation.
Compiled prose, not a quotation. It restates facts drawn from the cited rows above and adds none of its own. It is not itself a sourced record, so read the cited sections for the authoritative wording.
Not published in retained sources
These common buyer fields were explicitly outside the retained source coverage for this dossier. They are shown as omissions, not filled with a proxy, a related model or an assumption.
Research coverage
Evidence states describe the public material reviewed for this profile; they do not rate the company or assert an undisclosed fact.
- Corporate identity and location are retained from the official terms. Product facts and visual are limited to the Powerchain family. [S10]Company-stated
- Corporate identity and location are retained from the cited official source. Product facts and visual are limited to Eland N2XSY copper-conductor medium-voltage cable; no unlisted company-wide performance, stock, manufacturing-site or revenue claim is asserted. [S15]Company-stated
Frequently asked questions
What Drag Chain Cable product is documented for Eland Cables Limited?
The retained product material names Eland Powerchain drag-chain control cables. The dossier keeps this as a product-level statement rather than using it as a claim about the company's entire catalogue. [S6]
Which published rating and conductor should a buyer compare?
The cited product material records: 300/500 V with Class 6 extra-flexible copper conductors. Use the value as a product-level comparison point, while keeping the exact model and installation boundaries in the cited route. [S4]
Which published sheath and screening should a buyer compare?
The cited product material records: PUR or PVC sheath options; screened CY/CP variants use tinned-copper braid. Use the value as a product-level comparison point, while keeping the exact model and installation boundaries in the cited route. [S5]
Which common buying fields are not published in the retained sources?
The retained source packet does not publish Annual sales, Availability or stock. Those fields are intentionally left out of the procurement snapshot rather than inferred from a related series, a product image or the company identity. [S10][S15]
Research notes
The retained first-party packet supports a richer product-level reading surface, but it does not yet contain 600 words of distinct cited content. This noindex dossier remains in reviewing status until additional source-backed facts are retained.
- [S1] United KingdomUnited Kingdom
- [S2] LondonLondon
- [S3] elandcables.comelandcables.com
- [S4] 300/500 V with Class 6 extra-flexible copper conductors.300/500V; Class 6 Extra Flexible Copper conductor
- [S5] PUR or PVC sheath options; screened CY/CP variants use tinned-copper braid.PUR or PVC; Tinned Copper Wire Braid
- [S6] Eland Powerchain drag-chain control cables.Powerchain Cables
- [S7] Eland N2XSY copper-conductor medium-voltage cableEland N2XSY copper-conductor medium-voltage cable
- [S8] Eland Cables documents Powerchain as a highly flexible control-cable family for drag-chain applications.Powerchain Cables; highly flexible control cables for drag chain applications
- [S9] Compare Powerchain by sheath material, screened or unscreened construction, conductor arrangement and the actual drag-chain movement envelope.drag chain applications; 300/500V; PUR or PVC
- [S10] Corporate identity and location are retained from the official terms. Product facts and visual are limited to the Powerchain family.Eland Cables Limited; Powerchain
- [S11] EN 60811-404Powerchain CP Cable STANDARDS VDE 0482-332-1-2, EN 60811-404 Fire Retardant according to: IEC/EN 60332-1 THE CABLE LAB® AN ISO/IEC 17025 AND IECEE CBTL ACCREDITED FACILITY Our world-class testing facility assures the quality and compliance of this cable through a continuous and rigorous testing regime.
- [S12] The cited page lists 6/10 kV, 12/20 kV and 18/30 kV variants.The cited page lists 6/10 kV, 12/20 kV and 18/30 kV variants.
- [S13] It specifies a stranded Class 2 copper conductor with XLPE insulation and a PVC oversheath.It specifies a stranded Class 2 copper conductor with XLPE insulation and a PVC oversheath.
- [S14] Compare voltage grade, conductor cross-section, installation environment and IEC 60502-2 requirements before selection.Compare voltage grade, conductor cross-section, installation environment and IEC 60502-2 requirements before selection.
- [S15] Corporate identity and location are retained from the cited official source. Product facts and visual are limited to Eland N2XSY copper-conductor medium-voltage cable; no unlisted company-wide performance, stock, manufacturing-site or revenue claim is asserted.Eland Cables Limited; Eland N2XSY copper-conductor medium-voltage cable
- [S16] IEC 60502-2Standard / Voltage Rating : IEC 60502-2.
- [S17] aluminiumThis cable is similar in construction to NA2XSY cable , which has an aluminium conductor and which can sometimes be used as a cost-efficient alternative.
- [S18] Retained sourcePowerchain PUR cable