Manufacturer profile

Fritz Kübler GmbH

Fritz Kübler GmbH is a manufacturer based in Villingen-Schwenningen, Germany. [S2][S1]

Country
Germany [S1]
City
Villingen-Schwenningen [S2]

Procurement snapshot

Only hard product-level facts retained from the cited source route are shown below. A missing buying field is handled separately, rather than estimated from the listed series.

Inputs and output
Type 901 accepts 12–250 V AC/DC or NPN count/reset inputs and provides one relay output. [S4]
Display and enclosure
It uses a six-digit two-line LCD, 48 × 48 mm front, 45 × 45 mm cutout and IP65 front protection. [S5]
Kübler electronic preset counter 901
Official product image [S6]

Evidence scope

The retained official product route documents: Kübler documents Type 901 as a pulse and time preset counter with relay output. This dossier uses that cited route as the editorial scope. [S6]

The retained research coverage separates company identity from the named product evidence. It does not turn one model or series into a claim about unlisted company-wide operations. [S9]

Counter Meter

Documented series: Kübler electronic preset counter 901

Kübler documents Type 901 as a pulse and time preset counter with relay output. [S6]

Documented specifications for Counter Meter
Voltage range12 to 250 V [S10]
Inputs and output
Type 901 accepts 12–250 V AC/DC or NPN count/reset inputs and provides one relay output. [S4]
Display and enclosure
It uses a six-digit two-line LCD, 48 × 48 mm front, 45 × 45 mm cutout and IP65 front protection. [S5]
  • Kübler electronic preset counter 901 [S6]

Selection fit: Compare input circuit, relay requirement, display, cutout, battery supply and front protection before selection. [S8]

Digital Panel Meter

Documented series: Kübler Codix 565 process display for standard signals

Fritz Kübler GmbH manufactures Codix process displays and electronic evaluation instruments for industrial automation. [S11]

  • Kübler Codix 565 process display for standard signals [S7]

Selection fit: Use Codix 565 when a Kübler process display for standard signals is required; confirm input type, outputs and housing size against the exact Codix 565 configuration. [S7]

Product range and documented series

Kübler documents Type 901 as a pulse and time preset counter with relay output. [S6]

  • Kübler electronic preset counter 901 [S6]Source note: Kübler electronic preset counter 901
  • Kübler Codix 565 process display for standard signals [S7]Source note: Codix 565 Process controllers for standard signals electronic Product details - Kübler Group - Worldwide News

Procurement fit

The 901 preset counter is specified for applications requiring a 12 to 250 V supply with either 12 to 250 V AC/DC or NPN count and reset inputs, and where a single relay output is sufficient. The 96 x 48 mm Codix 565 is specified for applications requiring a process display for standard signals. Buyers should verify input type, output configuration, and housing dimensions against the exact Codix 565 configuration before release of order, since the documented record does not enumerate input ranges or output options for that model. Battery supply details for the 901 are not publicly documented.

Technical capabilities

For the 901, documented technical parameters include a 12 to 250 V voltage range, a 48 x 48 mm section size, IP65 ingress protection, a six-digit two-line LCD, a 48 × 48 mm front frame with a 45 × 45 mm cutout, and IP65 front protection. The device accepts 12 to 250 V AC/DC or NPN count/reset inputs and provides one relay output. For the Codix 565, documented parameters are a 96 x 48 mm section size and IP65 ingress protection. Display digit count, input signal ranges, and output specifications for the Codix 565 are not publicly documented.

Markets and applications

The 901 preset counter is documented for count and control tasks at 12 to 250 V where a panel cutout of 45 x 45 mm and IP65 front protection are specified. The Codix 565 is documented for indication of standard process signals into a 96 x 48 mm panel cutout with IP65 front protection. Specific industry verticals, reference installations, distributor channels, and application case studies are not part of the documented record for either product line. Selection should therefore be driven by electrical and mechanical interface rather than by sector specific endorsements.

Evidence limitations

The following common procurement fields are not publicly documented in the supplied record: operating temperature range, storage temperature, vibration and shock ratings, EMC compliance, RoHS, REACH, CE or UKCA marking, ATEX or IECEx ratings, battery type and life, output relay contact rating, count frequency maximum, display refresh rate, power consumption, terminal type, mounting depth, weight, warranty terms, lead time, and country of origin beyond Germany. Pricing is not publicly documented. The Codix 565 input type, output count, and digit count are not publicly documented. No third-party approvals or reference customers are publicly documented.

Editorial summary

Fritz Kübler GmbH is a German manufacturer with a documented location in Villingen-Schwenningen. The company appears in this directory under two categories: counter meter and digital panel meter. Under counter meter, the documented series is the Kübler electronic preset counter 901. Under digital panel meter, the documented series is the Kübler Codix 565 process display for standard signals. Both series are recorded as separate catalog entries, and no cross-reference between the 901 and the Codix 565 is part of the documented record. Additional corporate descriptors, founding date, ownership structure, and facility count are not publicly documented.

Compiled prose, not a quotation. It restates facts drawn from the cited rows above and adds none of its own. It is not itself a sourced record, so read the cited sections for the authoritative wording.

Not published in retained sources

These common buyer fields were explicitly outside the retained source coverage for this dossier. They are shown as omissions, not filled with a proxy, a related model or an assumption.

  • Annual sales [S9]
  • Availability or stock [S9]
Research coverage

Evidence states describe the public material reviewed for this profile; they do not rate the company or assert an undisclosed fact.

  • Identity and location are retained from the cited official source. Product facts and visual are limited to Kübler electronic preset counter 901; no unlisted company-wide performance, availability, production or revenue claim is asserted. [S9]Company-stated

Frequently asked questions

What Counter product is documented for Fritz Kübler GmbH?

The retained product material names Kübler electronic preset counter 901. The dossier keeps this as a product-level statement rather than using it as a claim about the company's entire catalogue. [S6]

Which published inputs and output should a buyer compare?

The cited product material records: Type 901 accepts 12–250 V AC/DC or NPN count/reset inputs and provides one relay output. Use the value as a product-level comparison point, while keeping the exact model and installation boundaries in the cited route. [S4]

Which published display and enclosure should a buyer compare?

The cited product material records: It uses a six-digit two-line LCD, 48 × 48 mm front, 45 × 45 mm cutout and IP65 front protection. Use the value as a product-level comparison point, while keeping the exact model and installation boundaries in the cited route. [S5]

Which common buying fields are not published in the retained sources?

The retained source packet does not publish Annual sales, Availability or stock. Those fields are intentionally left out of the procurement snapshot rather than inferred from a related series, a product image or the company identity. [S9]

Research notes

The retained first-party packet supports a richer product-level reading surface, but it does not yet contain 600 words of distinct cited content. This noindex dossier remains in reviewing status until additional source-backed facts are retained.