REQUEST FOR QUOTE → Request a quote
SpecForge Editorial Team

AS568 FKM O-Ring Size Chart and Dash Cross-Reference

Table of Contents
  1. How AS568 Dash Numbers Define an FKM O-Ring
  2. Selecting the Correct AS568 Series
  3. AS568, ISO 3601 and JIS B 2401 Compared
  4. Reading ID, CS, OD and Tolerances
  5. Static Groove Checks Prevent a Size Mismatch
  6. Where AS568 Is the Right Choice
  7. Procurement Checklist for FKM AS568 Seals
AS568 FKM O-Ring Size Chart and Dash Cross-Reference

AS568 dash numbers identify O-rings by inside diameter, cross-section, tolerances, and coded size, giving purchasing and inspection a common dimensional reference [S1].

To cross-reference a metric O-ring to AS568, match the cross-section first, then find the dash number with the closest inside diameter [S7].

How AS568 Dash Numbers Define an FKM O-Ring

The controlling dimensions for a standard AS568 O-ring are inside diameter and cross-section, with their applicable tolerances. Outside diameter is derived from OD = ID + 2 × CS and normally serves only as a reference, not as the primary compliance dimension [S5][S9].

Early sizes show how cross-section changes with the dash code. AS568-001 has a nominal ID of 0.029 inch and CS of 0.040 inch, AS568-004 has a 0.070 inch ID and 0.070 inch CS, and AS568-020 has a 0.864 inch ID and 0.070 inch CS [S3]. Metric equivalents follow the exact conversion factor of 1 inch = 25.4 mm [S3].

An FKM O-ring can use an AS568 dash code for size identification without changing the need to specify elastomer compound, hardness, temperature rating, and chemical compatibility. Dash number, material, and surface finish are separate purchase-order decisions.

Selecting the Correct AS568 Series

The 000 series has a 0.040 inch cross-section, the 100 series has 0.063 inch, the 200 series has 0.103 inch, the 300 series has 0.139 inch, and the 400 series has 0.210 inch [S3]. These series cross-sections align with listed ISO 3601 equivalents of 1.80, 1.60, 2.65, 3.55, and 5.30 mm respectively [S3].

For metric cross-referencing, match the cross-section before finding the dash number with the closest inside diameter [S7]. The JIS B 2401 values listed against these five series are 1.90, 1.50, 2.40, 3.10, and 5.70 mm, but their different values show why a nominal metric size cannot be treated as an automatic AS568 equivalent [S3].

A dash number is an identification code rather than a physical measurement. For example, AS568-210 does not represent 2.10 inch or 21.0 mm [S3]. Engineers should use the code only after confirming its listed ID and CS, then check whether the converted metric dimensions retain the required tolerance.

AS568, ISO 3601 and JIS B 2401 Compared

FKM O-ring size chart AS568 dash number cross reference - AS568, ISO 3601 and JIS B 2401 Compared
FKM O-ring size chart AS568 dash number cross reference - AS568, ISO 3601 and JIS B 2401 Compared

AS568 is the practical choice when a drawing, spare-parts database, or U.S.-style supplier catalog uses a three-digit dash number. ISO 3601 is more suitable when a drawing specifies metric inside diameter and cross-section directly, while JIS B 2401 serves specifications written around its own metric cross-section families [S3].

AS568 dash lookup, ISO 3601 and JIS B 2401 do not provide a one-to-one cross-reference because both ID and CS must be considered. The comparison table therefore separates cross-section from diameter and avoids matching a cord diameter against an ID [S3][S7].

The most common procurement errors are reversing ID and CS, treating a dash code as a dimension, or assuming that a converted metric seal inherits the same tolerance. For a mixed inventory, the O-ring sizing converter can support arithmetic, but the governing size standard must still control the order [S3].

Reading ID, CS, OD and Tolerances

AS568-004 has a nominal ID of 0.070 inch and a nominal CS of 0.070 inch [S3][S5]. AS568-010 has a nominal ID of 0.239 inch and a nominal CS of 0.070 inch [S3][S5]. These values show why nominal dimensions alone are insufficient for inspection or substitution.

AS568-001, AS568-002, and AS568-003 have nominal cross-sections of 0.040, 0.050, and 0.060 inch, respectively [S3].

Static Groove Checks Prevent a Size Mismatch

FKM O-ring size chart AS568 dash number cross reference - Static Groove Checks Prevent a Size Mismatch
FKM O-ring size chart AS568 dash number cross reference - Static Groove Checks Prevent a Size Mismatch

Static O-ring design guidance cited here applies to pressures below 1,500 psi and requires checking both nominal conditions and the tolerance stack-up [S4]. The design must account for the largest permissible O-ring installed in the smallest permissible groove [S4].

Final seal selection should account for groove dimensions, material, and operating conditions [S5].

Where AS568 Is the Right Choice

AS568 is one of the most common O-ring sizing standards, and final selection should account for groove dimensions, material, and operating conditions [S5][S6]. It is less convenient when the governing document specifies only metric ID and CS, since a converted seal may differ in tolerance or land in a different series [S3][S7].

This sizing system is not a material specification. FKM offers broad resistance to many oils, fuels, acids, and chemicals, but compound selection still requires compatibility and temperature review. For oilfield applications, Specify an Explosion-Resistant FKM Grade for Oilfield Seals addresses the separate grade-selection decision that cannot be resolved from an AS568 chart alone.

AS568-901 through AS568-932 are also a special case because they cover boss-seal applications, while the -001 through -475 families cover standard cord sections [S5]. A correct purchase order should state the complete dash number, material, hardness, nominal dimensions, and applicable tolerance rather than only a converted millimeter size.

Procurement Checklist for FKM AS568 Seals

FKM O-ring size chart AS568 dash number cross reference - Procurement Checklist for FKM AS568 Seals
FKM O-ring size chart AS568 dash number cross reference - Procurement Checklist for FKM AS568 Seals

Confirm the AS568 dash number, then verify both nominal ID and CS against the drawing or measurement. Convert inch dimensions at exactly 25.4 mm per inch, but preserve the original tolerance class and cross-reference standard [S3]. Material identification also needs a hardness value, since the same AS568 size can be produced in multiple FKM hardness grades.

For replacement work, measure the installed ring at its smallest ID and largest cross-section where access permits, then check gland dimensions and pressure conditions. FST guidance defines its static-seal recommendations for pressures below 1,500 psi, so higher-pressure service requires a separate engineering review [S4].

The next procurement checkpoint is a three-way signature: dimensional conformity to the governing AS568, ISO 3601 or JIS B 2401 requirement, plus FKM compound and hardness approval. Track any substituted metric seal against both ID and CS, and do not release it until groove fit, stretch or interference, and operating compatibility have been checked [S3][S4][S7].

Frequently asked questions

What are the nominal inside diameter and cross-section of an AS568-210 FKM O-ring?

AS568-210 is an identification code, not a physical measurement of 2.10 inch or 21.0 mm. Its listed nominal dimensions must be confirmed in the applicable AS568 chart before specifying it, including the tolerance values for both inside diameter and cross-section.

What cross-section is used by the AS568 100, 200, and 300 series?

The AS568 100 series uses a nominal 0.063 inch cross-section, the 200 series uses 0.103 inch, and the 300 series uses 0.139 inch. Their listed ISO 3601 equivalents are 1.60, 2.65, and 3.55 mm, respectively.

Can an ISO 3601 or JIS B 2401 size be converted directly into an equivalent AS568 dash number?

There is no automatic one-to-one cross-reference because inside diameter and cross-section must both match. Match the metric cross-section first, then select the AS568 dash number with the closest inside diameter, and verify that the converted tolerances remain acceptable.

What groove checks are required before ordering an FKM O-ring identified by an AS568 dash number?

Check the gland dimensions, compression, and tolerance stack-up, including the largest permissible O-ring installed in the smallest permissible groove. For the cited static-seal guidance, pressures are below 1,500 psi; gland height is calculated as H = CS minus specified compression, and groove width W must be greater than CS.

9 sources
  1. AS568 Size Chart
  2. AS568 O-Ring Size Chart & Dimensions
  3. O-Ring Sizing: Inch to Metric Converter & AS568 Dash Lookup
  4. O-RING REFERENCE AS568 SIZES
  5. O-Ring Size Chart (AS568): Dash Numbers, ID & CS
  6. AS568 O-Ring Size Chart | Measurement Guide
  7. Metric O-Ring to AS568: How to Cross-Reference (Oct 19, 2026)
  8. AS568 O-Ring Size Chart
  9. O-Ring Size Chart: AS568, Metric & Boss Specs (Jun 11, 2026)

Need to source matching manufacturers or get a quote?

SpecForge connects industrial buyers with verified manufacturers. Submit your requirement and we will route it to matched suppliers.

Submit RFQ now →
Ask SpecForge AI