A light curtain’s minimum safety distance is calculated from ISO 13855 as S = K × T + C, where K is the approach speed, T is total stopping time, and C accounts for detection resolution or reach-through geometry [S3][S4].
The calculation must use the installed safety system’s response time and the machine’s measured stopping time, not an estimate based only on the light curtain specification [S4][S5].
Define the calculation inputs
ISO 13855 provides the calculation structure S = K × T + C: S is the minimum distance in millimetres, K is the assumed body or body-part approach speed in millimetres per second, T is the total stopping time in seconds, and C is the additional distance in millimetres [S3][S4].
For perpendicular approach with alpha = 90 degrees, plus or minus 5 degrees, the approach-speed constant is 2000 mm/s for a calculated safety distance up to 500 mm and 1600 mm/s when the distance exceeds 500 mm [S4]. If the first result is greater than 500 mm, the calculation must be repeated with K = 1600 mm/s, and the recalculated distance must not be less than 500 mm [S1][S4].
The total stopping time combines at least the light curtain’s response time with the machine time required to remove the hazardous action [S4]. For an ANSI-based installation, the stopping-time analysis also includes light-curtain response, safety-control response, and machine response, with extra time allowed for variations in machine behaviour [S5].
Select the correct distance term
For a vertical light curtain that detects fingers or hands and can only be crossed through the sensitive area, the additional distance is C = 8 × (d − 14), where d is the light curtain’s detection resolution in millimetres [S4]. Published examples cover resolutions of 14, 20, 30, and 40 mm, producing C values of 0, 48, 128, and 208 mm [S4].
For light curtains intended to detect arms or legs, the additional distance is 850 mm and the approach-speed constant is 1600 mm/s [S4]. A 50 mm resolution therefore produces S = 1600 × T + 850, while the same equation applies to a 90 mm resolution [S4].
Horizontal arrangements may also be required when a person could otherwise occupy the danger zone without interrupting the sensing field [S4].
Compare the main installation cases
Vertical finger or hand detection, vertical body detection, and horizontal presence detection are selected by the hazard geometry rather than by a single universal formula [S4]. Vertical finger or hand protection uses K = 2000 or 1600 mm/s and C = 8 × (d − 14); once S exceeds 500 mm, the 1600 mm/s recalculation applies and S must remain at least 500 mm [S4].
Vertical arm or leg detection uses K = 1600 mm/s, while the additional distance depends on the applicable configuration and detection geometry rather than one universal term [S4]. Horizontal presence detection uses C = 1200 − (0.4 × H), with C no less than 850 mm, and addresses the risk that a person may be present inside the danger zone [S4].
ANSI-based vertical calculations instead use D = K × (Td + Ti + Tc + Ts + Tscm) + d [S5]. Here, the terms account for device, light-curtain, control-system, and machine stopping components, while d includes the penetration or reach-through term associated with the protective field [S5].
Work through a practical example
Consider a vertical finger-detection light curtain with a 20 mm resolution, a protective-device response time of 0.010 s, and a machine stopping time of 0.150 s. With T = 0.160 s and C = 8 × (20 − 14) = 48 mm, the initial calculation is S = 2000 × 0.160 + 48 = 368 mm [S4].
Because 368 mm is below 500 mm, the minimum safety distance is 368 mm for this worked case [S4]. If T were 0.310 s, the initial result would be 668 mm, requiring recalculation with K = 1600 mm/s: S = 1600 × 0.310 + 48 = 544 mm, which remains above the 500 mm floor [S1][S4].
For an arm-detection arrangement with the same 0.160 s stopping time, the result depends on the applicable arm-detection configuration and its additional-distance term [S4]. The difference from the finger-detection example reflects different detection capability, not a conservative adjustment, and should not be calculated using a universal 850 mm term [S4].
Measure and validate stopping time
ANSI guidance calls for 10 stop-time measurements, calculation of the mean, and addition of three standard deviations; the resulting value, or the highest of the 10 measurements, is used as the machine stopping-time input [S5]. This method captures variability that a single nominal timing run can conceal [S5].
ANSI B11.19-2019 also expresses the through-detection term for a vertical installation as ddt = 3.4 × (de − 7) mm, where de is the effective detection capability in millimetres [S5]. A 14 mm resolution gives 23.8 mm through-detection distance, while the corresponding ISO-based method in the cited material uses C = 8 × (d − 14) [S4][S5].
The two cited methods should not be blended without establishing the governing standard and machine type. ISO 13855 is the method identified for determining the minimum safety distance, while ANSI B11.19-2019 provides the cited ANSI calculation method [S4][S5]. A qualified safety engineer should resolve the applicable framework before installation.
Check installation geometry and residual risk
The calculated distance is not valid if a person can reach the hazard around, over, or through the sensing field without being detected [S4]. The light curtain must therefore be positioned so that reaching the hazardous point requires interruption of the protected area, and a person cannot remain inside the danger zone undetected [S4].
Where the calculated distance is impractically large, the cited engineering options are to reduce the machine’s total stopping time or improve the light curtain’s detection capability [S4]. A faster machine response reduces T; finer resolution reduces the resolution-based C term; neither change removes the need to verify reach-through and escape paths [S4].
The complete installation also has to be checked for functional suitability, including the safety light curtain, the associated safety relay, and any emergency stop function. If access must remain blocked until hazardous motion has ceased, guard locking may be more appropriate than a non-locking presence-sensing arrangement [S5].
Document the final installation
The final calculation file should identify the light-curtain model, detection resolution d, mounting orientation, approach angle, measured stopping-time method, response times, K value, C value, calculated S, and the physical mounting distance [S4][S5]. Any blanking configuration also changes how the protected field behaves, so fixed and floating blanking arrangements require separate functional review.
Verify the installed position after mounting, then repeat the stop-time measurement under the machine’s worst credible operating condition. Use the largest applicable S after recalculation and keep the installed distance from falling below the regulatory minimum [S1][S4].
Two trackable signals should close the loop: a documented stop-time test result and a measured beam height or field dimension from the installed device. If either changes, recalculate S before approving the safeguarding arrangement.