Use C11000 copper for high-current machined contacts because its conductivity is about 100% IACS, versus roughly 28% IACS for C26000 cartridge brass.
The decision hinges on current, heat, mechanical loading, corrosion exposure, production volume, and acceptable resistance, not on a universal winner between copper material and brass.
Electrical and Thermal Performance
Copper T2 has an electrical conductivity of 98–100% IACS [S3].
The resistance difference becomes a design variable because conductor heating increases with the square of current for a given resistance. Copper is therefore the defensible base material for high-current contacts, power-distribution interfaces, and heat-spreading connector bodies. One comparative machining table gives Copper T2 conductivity as 98–100% IACS and thermal conductivity as 401 W/m·K, against 25–30% IACS and 120 W/m·K for H59 brass [S3].
Brass remains practical when the contact carries low current and its contact resistance does not materially affect voltage drop, temperature rise, or system efficiency.
Strength, Threading, and Contact Mechanics
Brass is mechanically stronger than pure copper because zinc increases hardness and rigidity. Common H59 brass is reported at 100–120 HV and 390–440 MPa tensile strength, compared with 40–50 HV and 220–250 MPa for Copper T2 [S3].
This strength makes brass suitable for threaded pins, bushings, connector bodies, and parts subject to insertion torque or repeated mechanical loading.
For crimped terminals, copper offers a different advantage: its softness and ductility let it deform around wire strands and support a gas-tight cold-weld interface. ETP C11000 and oxygen-free copper are both identified for this purpose, with C11000 specified as approximately 99.9% pure copper [S2]. A spring-loaded contact that must survive repeated flex cycles requires a separate fatigue assessment rather than assuming that bulk conductivity alone will provide adequate life.
Machining, Tool Life, and Production Cost

Brass machines more predictably than copper because its chip formation is easier to control. Copper is comparatively gummy, tends to adhere to cutting tools, and can increase tooling wear and cycle time. Brass H59 is listed at 90% machinability relative to a 100% free-cutting-steel reference, while Copper T2 is listed at 40% [S3].
For complex CNC geometry, that difference can dominate the piece cost even when brass has poorer electrical performance. Copper can still be the correct choice for a high-current connector because the material specification must satisfy electrical requirements first, while production planning can reduce machining time through tooling, feeds, speeds, and chip evacuation. A comparative study identifies brass as the preferred option for high-volume CNC parts, complex geometries, cost-sensitive prototypes, and precision mechanical housings [S3].
The raw-material price is not a complete cost comparison. One 2026 guide placed pure copper at roughly $4–$5 per pound [S6], but finished-part economics must also include cycle time, scrap risk, tool consumption, plating requirements, and inspection. Brass is commonly cheaper than copper on a relative material basis, although the final connector price still depends on geometry, volume, and process controls [S3][S4].
Corrosion, Plating, and Environmental Limits
Copper forms a protective greenish copper-carbonate patina in air and moisture, while brass has good general corrosion resistance but can suffer dezincification in acidic or chloride-rich environments [S4]. That distinction matters for marine, process-plant, and outdoor connectors, particularly when moisture can remain trapped at a mating interface.
Both materials are usually plated in production connectors, so plating system, thickness, porosity, and contact geometry require separate qualification. Brass is easier to machine into repeatable small features, while copper offers lower bulk resistance before and beneath the plating. Neither material should be accepted for a wet, salty, or acidic service solely from a general corrosion-resistance statement.
Connector-Type Selection Matrix

For a high-current power contact, compare copper for approximately 100% IACS, 220–250 MPa tensile strength, 40% relative machinability, and 401 W/m·K thermal conductivity against H59 brass at 25–30% IACS, 390–440 MPa, 90% machinability, and 120 W/m·K. Copper wins on electrical and thermal performance; brass wins on strength and CNC production efficiency [S3].
For a crimped terminal, prioritize C11000 or oxygen-free copper because the required deformation around conductor strands creates the electrical interface. For a threaded or insertion-loaded terminal, brass usually provides the better combination of 100–120 HV hardness, 390–440 MPa tensile strength, and 90% machinability [S2][S3].
For a machined housing that carries little current, brass is often the economical selection because its 25–30% IACS conductivity is not the governing requirement. For a shield can, EMI requirement, thermal path, or mixed connector, copper may remain necessary even when only one region carries high current. The correct review order is electrical and thermal function, mechanical duty, environment, then manufacturing cost [S3].
Application Boundaries and Procurement Checks
Copper is not the right general substitute for brass when a connector must retain threads, resist handling damage, or be machined in large batches at controlled cost. Brass is not the right substitute for copper when current density, voltage drop, temperature rise, or heat spreading defines connector performance [S2][S5].
Specify the alloy and temper, not only the family name. C11000 ETP copper and C26000 cartridge brass provide useful property baselines, but actual conductivity, tensile strength, hardness, and machinability vary with temper and product form. Typical ranges include 220–380 MPa tensile strength for C11000 and 300–440 MPa for C26000, with C26000 yield strength reported at 124–310 MPa [S4].
Final drawings should also define plating, dimensional tolerances, surface roughness, contact normal force, current rating, temperature-rise test conditions, and the mating environment. Those interfaces determine whether the material advantage survives assembly. A practical review starts with the maximum current and allowable temperature rise, then validates the selected grade against thread retention, fatigue, corrosion exposure, and machining yield. Further detail on copper electrical conductivity in %IACS helps normalize resistance comparisons across material data sheets.