Fixed blanking disables a defined beam zone for a stationary obstruction, while floating blanking tracks a moving object within a configured beam limit.
Both functions permit necessary intrusions into a light curtain’s protective field, but they suit different machine geometries, motion patterns, and validation workflows.
Blank zone definition and detection behavior
Blanking permits an opaque object to occupy part of a light curtain protection field without triggering the safety function, provided the required safety conditions are satisfied. It is intended for material being processed and for fixed or mobile machine parts that necessarily cross the protective field [S1].
Fixed blanking defines the blanked area by both size and position. Floating blanking defines only the size, allowing the occupied beams to move within the protected area [S5]. This distinction is the primary engineering decision because fixed blanking protects a known installation geometry, while floating blanking accommodates a moving workpiece or fixture.
Floating blanking requires the occupied beams to remain adjacent and must not exceed the configured number of beams [S1]. The remaining protective field retains its normal detection function, and the device monitors whether the expected object is present [S5].
Selection criteria for the blanking mode
Choose fixed blanking when the obstruction does not move, including a permanent bracket, guard rail, conveyor component, or fixture at a known elevation [S6][S7]. The beam pattern can be configured to the exact obstruction, allowing all unblanked beams to operate normally [S1].
Choose floating blanking when a workpiece, carrier, hose, or slide must travel through the protection field. SICK identifies these as typical permitted objects, while ReeR specifies adjacent occupied beams and a configured upper limit [S1][S5].
Fixed blanking offers simpler geometry and less setup variation, but it is unsuitable for an object that changes position or size. Floating blanking accepts movement, but the protection depends on correct configuration of the allowed opening and on the light curtain detecting an object that is missing [S5].
Fixed, floating, and programmable blanking compared

Fixed blanking offers the narrowest configuration freedom but the clearest installation definition: size and position are both specified [S5]. It fits permanent structures and repeatable tooling positions, with little need to accommodate travel or changing beam occupancy.
Floating blanking defines the opening size while permitting position to vary [S5]. It fits moving workpieces and adjustable production equipment, but setup must limit the permitted number of adjacent beams [S1]. The optional Remote Status Display for the Pinnacle Systems Model CA includes a diagnostic scrolling-message display with 5 ft (1.5 m) of connector cable.
Programmable blanking adds configuration flexibility beyond the fixed-versus-floating distinction, but its acceptance depends on the actual model and controller. Fixed blanking is therefore the preferred choice for a stable obstruction, floating blanking for controlled movement, and programmable blanking where a machine platform requires configurable beam patterns. The comparison should be made against obstruction position, permitted travel, setup effort, and detection of a missing object.
Application-specific recommendations
For a fixed bracket or guard-rail member, configure fixed blanking at the precise beam location and leave every other beam active [S1][S7]. For a press or fabrication cell in which a workpiece moves vertically or horizontally, floating blanking permits the workpiece to pass without stopping the machine [S4].
This is one product implementation, not a universal beam-resolution rule, so the selected light curtain’s manual must control the actual dimensions and safety-distance calculation.
Automatic blanking is appropriate where conveyors, brackets, or fixtures vary in size or position. The described Model CA Auto Blank option blanks only the required beams and enters a stop mode if the obstruction moves or is removed [S4]. It reduces manual beam counting but does not remove the need for application validation.
Failure modes and validation constraints

A manually selected blanking window can be configured larger than the physical obstruction, leaving an unintended opening in the protective field. The Model CA documentation identifies oversized manually blanked areas as a known safety concern and describes Auto Blank as a method that limits blanking to the obstruction area [S4].
Missing-object detection is a defining distinction from simply reducing light-curtain resolution. With blanking, the safety function is triggered if the expected object is not present [S5]. Validation must therefore cover both an authorized object entering the protected area and the removal, loss, or unexpected movement of that object.
Moving equipment also affects setup controls. A keyed selector, diagnostic display, and yellow blanking-active indicator are used in the documented Model CA implementation to make mode and status visible outside the control panel [S4]. The safety light curtain must still be validated as part of the machine’s complete safety system, including its safety relay or other final control elements.
Configuration, commissioning, and sourcing records
Record the intended obstruction, its permitted size, its permitted position, and the number of beams affected before configuring blanking. For fixed mode, document the exact size and position [S5]. For floating mode, document the maximum opening and verify that occupied beams remain adjacent [S1].
Use the manufacturer’s instructions for the exact model and firmware configuration. Product examples illustrate the range of implementations: Model CA offers fixed, floating, and automatic options, while its RSD uses red, green, and yellow indicators, a diagnostic display, a 1.5 m connector cable, and a keyed selector switch with a yellow blanking-active indicator [S4].
For procurement, specify the light-curtain model, protection geometry, resolution, blanking mode, permitted opening, beam count, response and safety-distance requirements, output interface, and diagnostic requirements. Blanking is an auxiliary function of the safety light curtain, not a substitute for mechanical guarding or a complete risk assessment.
Verify the decision by testing static obstruction stability for fixed mode, full travel and adjacent-beam behavior for floating mode, and missing-object response for either mode, then archive the approved configuration and validation results.