FRP bolted connections can fail by bearing, cleavage, or delamination before steel connections reach the familiar bolt-shear or net-section limit states [S2][S5].
The comparison applies to pultruded FRP profiles and steel fasteners, where orthotropy, low through-thickness strength, and limited local crushing control the design.
Why FRP bearing Failure Differs from Steel
In a steel bolted connection, the characteristic local limits are bolt shear and plate net-section tension; FRP adds bearing, cleavage and pull-out, and through-thickness delamination [S5]. Bearing is crushing and cutting of fibers around the hole wall, rather than ductile hole elongation or plate yielding.
Pultruded FRP is orthotropic. Its longitudinal fibers carry axial load efficiently, but transverse and through-thickness behavior is weaker, so a connection checked only with a steel-style bearing equation can be unsafe. The material properties must be verified in the actual load direction [S5].
This is not a cosmetic variation in failure appearance. FRP composites are brittle, especially in tension and shear, and localized stresses around a hole can produce sudden failure rather than the familiar yielding warning in steel [S2].
Steel Versus FRP: Failure and Capacity Comparison
The decisive difference is the governing limit state: steel commonly reaches bolt shear or plate net-section tension, while FRP commonly reaches local bearing, edge cleavage, or delamination [S2][S5]. An FRP joint can therefore have adequate steel fastener strength but inadequate laminate capacity.
A useful comparison is steel versus FRP on four criteria. First, bearing behavior: steel holes generally deform before major loss of resistance, whereas FRP hole walls can be crushed and split by fiber damage. Second, tension: steel plates can yield and redistribute stress, but FRP lacks comparable ductility. Third, edge sensitivity: steel has established net-section and block-shear checks, while FRP requires cleavage-sensitive geometry and fiber-direction checks. Fourth, inspection: steel deformation can provide visible warning, but FRP cracking and delamination may be internal and require detailed examination [S2][S4].
The literature on FRP composite profiles describes pultruded members as orthotropic and fiber-oriented, which is why copying steel connection details without rechecking the load path is unreliable.
Geometry, Material Orientation and Edge Distance

One design guide gives a minimum edge distance of 2.0 bolt diameters, increasing to 3.0 diameters in the pull direction for cleavage-critical joints; it also gives 4.0 diameters as the recommended pitch and row spacing [S5]. These are design-guide values, not universal code limits, so the governing project standard and manufacturer test data must control.
Bolt diameter for structural work is typically M10 to M20 in the cited FRP guidance [S5]. Increasing diameter does not proportionately improve capacity because the laminate behind the hole governs, and two smaller bolts can outperform one oversized bolt.
Material direction changes the result. The cited guide states that pultruded material carries load along its fiber direction roughly twice as well as across it [S5]. Bolt rows should therefore be arranged to minimize shear across the reinforcement and splitting along the fiber planes.
The experimental campaign tested four beam-to-connection types using stainless-steel cleats, varying cleat thickness and number of bolts, and determined connection resistance, stiffness, and ductility [S3].
Fastener Choice Does Not Rescue the Laminate
The study developed interfacial models for an FRP profile-to-concrete bolt connection, considering combined shear-bending near failure and the development of a mechanical model for cleavage failure of the FRP plate [S1].
For corrosive service, the FRP guidance lists 316 stainless steel or GRP threaded rod, with A2-70 and A4-70 identified as typical grades. Large-diameter flat washers on both faces spread clamp load, while EPDM or nylon sleeves can isolate steel from FRP and interrupt the electrical path [S5].
FRP fasteners should not be selected merely to eliminate galvanic corrosion. The carbon fiber composite or industrial ceramic alternatives have different stiffness, strength and installation characteristics, so their suitability must be established for the actual composite system.
Installation, Preloading and Inspection

Punching or power-reaming unbacked laminate can create concealed splits between plies.
Clamping must support the intended load path. Connections carrying tension across the member should use clamped friction detailing or bonded inserts where net-section and cleavage govern [S5].
Over-torquing is not a substitute for design. The literature identifies localized high stress and brittle behavior as central risks in PFRP joints, while the FRP guide warns that tight punching and hard torquing can damage the laminate [S2][S5]. Preload, washer area, bolt grade and installation procedure therefore belong in the connection specification.
Inspection should distinguish fastener movement from laminate damage. Relevant indicators include ovalized or crushed holes, local splitting, delamination at the interface, cracked edges and bolt slip, with the acceptance criteria tied to the specified laminate and loading direction [S4].
Application Limits and Sourcing Requirements
FRP bearing-led detailing is appropriate where corrosion resistance, low weight or electrical isolation is required, but the joint must be verified for bearing, cleavage, pull-out and delamination rather than checked only for bolt strength [S5]. It is less suitable for designs that require steel-like connection ductility, extensive post-fearing redistribution or connections created by welding.
Steel remains appropriate where predictable yielding, standardized slip behavior, heavy load paths or conventional fabrication controls dominate. The selection question is not simply which material has the higher nominal strength, but which material retains the required resistance under the actual local stress direction and service environment.
Source data should identify the FRP architecture, fiber orientation, profile and plate thickness, bolt diameter and grade, edge distance, pitch, washer arrangement, preload procedure and exposure environment. A 2025 FRP-to-concrete study found bolt deformation concentrated near the interface and combined shear-bending action near failure [S1], while pultruded lap-joint research compared single- and multi-hole specimens using measured material properties and finite-element analysis [S4].
Close the specification by recording which limit state governs each bolt group, the allowable bearing direction, minimum edge distances, hole tolerance, fastener grade, isolation material and inspection criteria, then validate the selected configuration against representative test evidence [S1][S2][S4].