How to Calculate a Safety Function Performance Level

Calculate Performance Level in two separate stages: establish PLr from severity, exposure frequency, and avoidance, then calculate achieved PL from architecture, MTTFd, DCavg, and CCF [S3].

EN ISO 13849-1 defines five Performance Levels, PL a through PL e, for safety-related parts of control systems, with PL e representing the highest dangerous-failure performance [S4][S5].

Separate the required PL from the achieved PL

PLr is the output of the machine risk assessment, while the achieved PL describes the reliability of the implemented safety function. The design passes only when the achieved PL equals or exceeds PLr [S3][S2].

The distinction controls the sequence of engineering work: define the safety function, determine PLr, design and implement the architecture, calculate achieved PL, and verify compliance. Treating PLr and achieved PL as one calculation creates an unsupported claim because their inputs differ [S2].

For an emergency-stop function, for example, the risk graph determines whether PLr c, d, or e is needed. A safety relay cannot be selected before that target is fixed, because its diagnostic architecture, reliability data, and common-cause controls determine the achieved PL.

Determine PLr from the ISO 13849-1 risk graph

The risk graph evaluates three parameters: severity S, frequency and duration of exposure F, and possibility of avoidance P. S1 covers slight, normally reversible injuries, while S2 covers serious, normally irreversible injuries, including death [S3][S5].

Exposure runs from F1, seldom or short exposure, to F2, frequent or continuous exposure. Avoidance is P1 when the hazard can be avoided under specific conditions and P2 when avoidance is scarcely possible [S3][S5]. The risk-graph method is used to determine PLr [S7].

The resulting combinations typically map as follows: S1/F1 produces PLr a; S1/F2 produces PLr b to c; S2/F1 produces PLr c to d; S2/F2 with P1 produces PLr d; and S2/F2 with P2 produces PLr e [S3]. This calculation belongs to the risk assessment, not the component selection stage.

Calculate achieved PL from four design inputs

The achieved PL is calculated from category, MTTFd, DCavg, and common-cause failure, or CCF. These inputs describe the architecture, component reliability, diagnostic performance, and protection against shared faults [S3][S5].

Category B uses a single channel with basic design and no redundancy. Category 1 uses a single channel incorporating well-tried components and safety principles. Category 2 adds testing so that a fault is detected by the next test rather than immediately [S3].

Category 3 uses redundancy and diagnostics so that a single fault does not cause loss of the safety function. Category 4 extends this architecture with high diagnostic coverage and the capability to tolerate faults while maintaining the required performance [S3].

Manufacturer safety characteristics supply the component-level data for these calculations. A calculation based only on a device’s nameplate rating is incomplete because the complete safety function includes input, logic, output, wiring, diagnostics, and common-cause safeguards [S5].

Compare the main calculation routes

The central comparison is between risk selection and design verification: PLr uses S, F, and P and answers how reliable the function must be; achieved PL uses category, MTTFd, DCavg, and CCF and answers how reliable the implementation is [S3].

PL and SIL are not interchangeable labels. EN ISO 13849-1 and IEC 62061 use different classification systems and definitions, and the applicable route depends on the technology, risk classification, and architecture [S5].

Apply the method to real safety functions

A guard door with a monitored interlock is assessed against the hazard created when the guard is open, including the frequency of access and whether a person can avoid the dangerous zone. The required Performance Level (PLr) is determined from the risk assessment for each safety function, while the achieved PL is determined separately from the safety function's category, mean time to dangerous failure (MTTFd), average diagnostic coverage (DCavg), and common cause failure (CCF).

A hazardous machine-tool feed requires an emergency-stop function whose demand condition, hazard severity, and exposure duration are documented before architecture selection. For a press application with frequent exposure and scarce avoidance, S2, F2, and P2 lead to PLr e, which demands a substantially stronger evidence package than PLr d [S3].

A safety light curtain used as a protective device must be considered within the complete safety function, not as an isolated component. Its sensing performance, muting logic, stop path, reset arrangement, response time, and CCF controls all affect the achieved PL.

Identify failure modes and weak evidence

The most common calculation error is selecting components before establishing PLr. Another is claiming a high PL from architecture alone while omitting MTTFd, DCavg, or CCF. A third is inflating avoidance to move from PLr e to PLr d without evidence [S3].

Unverified assumptions also undermine the result: using generic catalogue data instead of manufacturer safety characteristics, ignoring wiring and interface contributions, treating a periodic test as equivalent to immediate fault detection, or omitting common-cause failure from a redundant architecture [S3][S5].

The final validation should preserve the risk-graph inputs, component safety data, architecture diagram, diagnostic assumptions, CCF score, test interval, and the numerical comparison of achieved PL with PLr. These records make the safety argument reviewable during commissioning and future modifications.

Maintain the PL through equipment changes

Proof-test intervals and lifecycle assumptions must be controlled because the achieved PL depends on when faults are detected and how long the safety function remains available. The proof test interval should therefore be traced to the selected architecture and diagnostic method. [S3]

Any change to input devices, control logic, contactors, output devices, wiring, or reset logic requires review against the original calculation. Replacing one component with an equivalent catalogue item does not by itself prove that category, MTTFd, DCavg, and CCF remain unchanged [S5].

For validation, record one result per safety function: PLr, category, MTTFd, DCavg, CCF, achieved PL, and the pass condition. Recheck the calculation after hardware changes, software changes, maintenance substitutions, or changes to the operating hazard.

Frequently asked questions

Which ISO 13849-1 risk-graph parameters determine the required performance level PLr?

PLr is determined from severity S, exposure frequency and duration F, and possibility of avoidance P. S ranges from S1 for slight, normally reversible injuries to S2 for serious, normally irreversible injuries; F ranges from F1 for seldom or short exposure to F2 for frequent or continuous exposure; and avoidance is P1 or P2.

What risk-graph combination produces PLr e under EN ISO 13849-1?

An S2, F2, P2 combination produces PLr e, representing the highest Performance Level. This combination applies where the hazard can cause serious or irreversible injury, exposure is frequent or continuous, and avoidance is scarcely possible.

Which four design inputs are required to calculate a safety function’s achieved PL?

The achieved PL is calculated from the architecture category, MTTFd, DCavg, and common-cause failure score. These inputs must be supported by manufacturer safety characteristics and must cover the complete safety function, including input, logic, output, wiring, diagnostics, and common-cause safeguards.

When does a safety function design satisfy its ISO 13849-1 PL requirement?

The design passes when the achieved PL equals or exceeds the required PLr. PLr comes from the machine risk assessment using S, F, and P, whereas achieved PL reflects the implemented architecture, component reliability, diagnostic performance, and protection against shared faults.

8 sources
  1. PL (Performance Level) :Safety Knowledge
  2. EN ISO 13849-1 ► Basis for Performance Level
  3. How to Calculate Performance Level (PL) under ISO 13849 (Jun 23, 2026)
  4. Performance level in safety applications
  5. Performance Level | Blogs
  6. CALCULATION OF THE PERFORMANCE LEVEL
  7. Determination of the required PL (PLr ) according to ISO ... (Aug 22, 2023)
  8. Performance Levels Explained (2 days ago)

Need to source matching manufacturers or get a quote?

SpecForge connects industrial buyers with verified manufacturers. Submit your requirement and we will route it to matched suppliers.

Submit RFQ now →
Ask SpecForge AI