A No. 32 metric reinforcing bar has a nominal diameter of 32 mm and a gross cross-sectional area of about 804 mm² [S1][S5].
The required shear force is the bar's cross-sectional area multiplied by its allowable shear strength, with additional allowance for blade clearance, wear, cutting speed, and machine capacity.
Start with the 32 mm bar geometry
The No. 32 metric designation identifies a reinforcing bar with a 32 mm nominal diameter [S1]. Its gross area is calculated as A = πd²/4, giving 804.25 mm² for d = 32 mm.
This gross area is the starting point for estimating a direct single-shear cutting force. It is not, by itself, the allowable machine load.
That value belongs to that particular example and should not be transferred to an unidentified rebar grade.
Use the strength basis appropriate to the calculation
That expression is a design provision for bolted connections, not a rebar-cutting rule, but it demonstrates how a shear factor, material strength, and intersected area are combined.
Compare the practical cutting methods

A hydraulic shear, mechanical rebar cutter, abrasive cut-off saw, and cold saw require different force and machine checks. Hydraulic shears develop force through the cutter stroke and are commonly specified by the maximum bar diameter they can cut.
An abrasive cut-off saw removes material by abrasion rather than shearing the entire section in one stroke. A cold saw uses a toothed wheel and controlled feed, so motor power, tooth loading, and feed rate matter more than a single static shear-force figure.
For production lines, the operating choice also changes because of cycle time, cut length, and handling requirements. The comparison between flying-shear and stop-start cutting for rebar lines is useful at that stage, but the static cutting-load calculation should be completed first.
Separate required force from machine capacity
The calculated bar force is only one part of machine selection.
For hydraulic equipment, the available cutter force should be compared with the calculated load plus a documented operating margin. The margin should cover normal wear and production variation, not compensate for an unknown bar grade or an unsuitable machine.
Set the calculation method by application

The rebar cutter decision should then be checked against the required bar diameter and rated capacity. [S5]
For high-volume fabrication, include cycle time, support requirements, blade consumption, and end-cut quality. A machine with adequate peak force can still perform poorly if the stock is inadequately supported or if repeated repositioning controls the cycle.
For cold or abrasive sawing, motor rating, wheel speed, tooth or wheel condition, cooling, and sparks control matter. Those operating factors explain why a calculated shear load should not be treated as a guarantee that a given saw will complete the cut safely.
Build a defensible field calculation
Check units at every step. A force in kN multiplied by an area in mm² does not directly produce stress in MPa. Conversely, 804.25 mm² multiplied by a strength in N/mm² produces newtons, and division by 1,000 converts the result to kN.
Before cutting, verify that the tool matches the rebar-cutting machine class intended for the application, that the workholding is adequate, and that the operator controls include a guarded cut-off or shear zone. The final acceptance criterion is that the machine can complete the cut within its rated operating envelope.