How to Select the Coding Level for a Safety Interlock

Table of Contents
  1. ISO 14119 Coding Bands and Interlock Types
  2. Coding Decision Criteria for Guard Defeat
  3. Low, Medium, and High Coding Compared
  4. Who Needs Each Coding Level
  5. Installation Measures That Change the Decision
  6. Guard Locking and Power-Failure Behavior
  7. Verify the Exact Model and Series Architecture
How to Select the Coding Level for a Safety Interlock

Select low, medium, or high coding by comparing the risk of guard defeat with the number of actuator variants, then confirm the device’s declared coding and machine safety function.

The safety interlock switch monitors a movable guard; it does not stop hazardous motion by itself, and guard locking requires a separate stopping-time assessment.

ISO 14119 Coding Bands and Interlock Types

ISO 14119 defines low coding as 1 to 9 code variations, medium coding as 10 to 1,000 variations, and high coding as more than 1,000 variations [S1]. These bands describe how many different actuator codes the sensor accepts, not the Performance Level or Category of the complete safety circuit.

The standard also separates interlocking devices into 5 types: Type 1, uncoded mechanically actuated devices; Type 2, coded mechanically actuated devices; Type 3, uncoded non-contact sensors; Type 4, coded non-contact sensors; and Type 5, trapped-key systems [S1]. Type 5 was added in the 2024 edition, having previously been addressed by ISO/TS 19837 [S1].

The distinction matters because a high coding level is not a synonym for high safety performance. A coded actuator can reduce the chance of bypassing the guard with a spare actuator, while the ability of the safety relay, wiring, contact arrangement, and diagnostic coverage determines what the safety circuit can achieve [S1][S6].

Coding Decision Criteria for Guard Defeat

Start with the machine risk assessment, not with the highest available coding level, because EN ISO 14119 requires the appropriate device type and coding level to be determined from the assessed risk of defeat [S3]. A high-coded device can be justified where bypassing the guard provides a strong operational incentive, such as faster setup, cleaning, or troubleshooting while the guard is open [S1].

Use the safety interlock switch type and coding level as separate decision gates. Type 2 and Type 4 devices are coded, but their coding bands can still differ; an RF-coded actuator does not prove high coding unless the exact model’s declared code population supports that classification [S1][S2].

For coded types, ISO 14119 defines low coding as 1 to 9 code variations, medium coding as 10 to 1,000, and high coding as more than 1,000, with more variations making the device harder to defeat using a spare actuator or an easily available part [S1].

Low, Medium, and High Coding Compared

how do you decide the coding level needed for a safety interlock switch? - Low, Medium, and High Coding Compared
how do you decide the coding level needed for a safety interlock switch? - Low, Medium, and High Coding Compared

Compare low, medium, and high coding on four criteria: accepted actuator variants, effort required to fit an unauthorized actuator, installation measures, and administrative burden. Low coding covers 1 to 9 variants, medium covers 10 to 1,000, and high covers more than 1,000 [S1].

The comparison is about defeat resistance, not automatic safety-category escalation. Categories B, 1, 2, 3, and 4 describe how the safety circuit is wired, how faults are detected, and how the system responds [S6]. The category and any claimed Performance Level must therefore be evaluated separately from the actuator coding band.

Who Needs Each Coding Level

Low coding may be suitable for a straightforward guard where the risk assessment finds little incentive to bypass the interlock and additional measures prevent simple defeat. Medium coding fits installations where several actuator codes are needed, but unauthorized substitution remains a credible concern. High coding is intended for applications where deliberate tampering or rapid bypass could materially improve production or maintenance performance [S1][S3].

High coding is not automatically best for every machine. It can narrow actuator interchangeability, complicate replacement and teach procedures, and requires procurement controls to ensure the correct actuator remains available. For an RFID switch, unique encoding can prevent operation with another tag or an ordinary magnet, whereas a universal or multi-code configuration accepts a broader population of actuators [S5].

Do not use coding as a substitute for the machine’s safety architecture. A non-contact sensor with a unique code can improve tamper resistance, but the switch still has to be integrated with a compatible safety-control system, suitable final switching elements, and a validated stop function [S2].

Installation Measures That Change the Decision

how do you decide the coding level needed for a safety interlock switch? - Installation Measures That Change the Decision
how do you decide the coding level needed for a safety interlock switch? - Installation Measures That Change the Decision

Type 2 interlocking devices are coded, mechanically actuated devices such as safety switches operated by a separate actuator tongue fitted to the door [S1]. If that mounting condition cannot be achieved, the installation does not match the assumed coded-device protection level, regardless of how many code variations the sensor can accept.

The coding level for defeat mitigation is selected after the locking principle and holding force, and before contacts, wiring, and mechanical accessories are selected [S2]. A plausibility check can reduce the chance that an unauthorized actuator is accepted, but it does not turn low or medium coding into high coding.

Positioning and guarding also affect the complete safety function. The safety light curtain reference explains how ISO 13855 approach-speed calculations determine safety distance, and the same guard-opening access time must be compared with the machine’s stopping time when deciding whether guard locking is necessary [S1].

Guard Locking and Power-Failure Behavior

Use guard locking when hazardous motion continues after the guard opens long enough for a person to reach the hazard. The decision compares total time to reach a safe state with the time required to open the guard and access the hazardous zone [S2].

Power-to-release locking holds the guard locked when power is lost and is normally preferred for personal protection against a coasting hazard [S1][S2]. Power-to-lock releases the electromagnetic hold when power is removed, so it should be selected only through a risk assessment that addresses the power-failure hazard [S1][S2].

Also plan controlled escape or maintenance release where personnel could be trapped inside the cell [S2]. Guard locking, process locking, and personnel-protection locking are different safety functions and should not be treated as interchangeable.

Verify the Exact Model and Series Architecture

how do you decide the coding level needed for a safety interlock switch? - Verify the Exact Model and Series Architecture
how do you decide the coding level needed for a safety interlock switch? - Verify the Exact Model and Series Architecture

Require the manufacturer’s exact declaration for the device type, coding level, teaching or replacement procedure, and actuator variants; do not infer the coding level from a product family, RFID label, or “safety” claim [S2]. ISO 14119 was published in its third edition in September 2024, with the harmonized EN ISO 14119 transition replacing the previous edition in September 2026 [S1].

Check the electrical architecture before claiming the final Performance Level. Series-connected potential-free contacts can mask a fault at one door, reducing diagnostic coverage and the achievable Performance Level to PL d or even PL c [S1]. Type 1 and Type 2 devices require redundancy to reach PL e, while one Type 3 or Type 4 sensor compliant with IEC 60947-5-3 can reach PL e [S1].

Record the risk assessment, coding rationale, actuator mounting method, anti-defeat measures, stopping time, guard-locking release logic, circuit architecture, and required replacement controls. Two traceable signals should close the selection: the manufacturer’s coding declaration for the ordered model and the final safety validation covering defeat, faults, stopping time, and power loss.

Frequently asked questions

What actuator variation ranges define low, medium, and high coding under ISO 14119?

ISO 14119 defines low coding as 1 to 9 code variations, medium coding as 10 to 1,000 variations, and high coding as more than 1,000 variations. These bands describe the number of different actuator codes the sensor accepts, not the Performance Level or Category of the complete safety circuit.

Does an RF-coded safety interlock automatically qualify as high coding?

No. Type 2 and Type 4 devices can be coded, but the coding band depends on the exact model’s declared code population; an RF-coded actuator alone does not prove high coding. The device specification must support a declared classification of more than 1,000 code variations.

What additional anti-defeat protection is required for low- or medium-coded interlock devices?

Low- and medium-coded devices require at least one further anti-defeat measure, such as mounting beyond practical reach, physical shielding, or plausibility checking with another device. A plausibility check may reduce unauthorized-actuator acceptance, but it does not convert the device into a high-coded product.

9 sources
  1. What do interlocking device types and coding levels mean? (Oct 29, 2026)
  2. How to Choose a Safety Door Switch / Interlock (Oct 10, 2026)
  3. Uniquely coded safety switches (Feb 14, 2025)
  4. Safety Interlock Switch: ISO 14119 & Guard Locking (Nov 5, 2026)
  5. How to Choose the Right Non-contact Safety Switch: Types, Advantages, and Applications (Aug 8, 2025)
  6. Selecting the Right Interlock Switch Safety Category Level
  7. Recommended Reading: Selecting the Right Safety Category Level for Interlock Switches (Apr 25, 2024)
  8. The internationally unique electromechanical safety switches and interlocks with high c…
  9. Rules for safety switches

Need to source matching manufacturers or get a quote?

SpecForge connects industrial buyers with verified manufacturers. Submit your requirement and we will route it to matched suppliers.

Submit RFQ now →
Ask SpecForge AI