A pressure sensor specification table must separate the compensated temperature range, where the stated accuracy applies, from the operating temperature range, which describes safe use without damage [S2][S5].
For example, a Honeywell TruStability SSC device is calibrated from -20°C to 85°C and uses an on-board ASIC to compensate offset, sensitivity, temperature effects, and nonlinearity [S3].
Compensated range and operating range are different limits
The compensated temperature range is the interval over which the specified temperature error and temperature coefficients are valid; it does not mean that temperature error becomes zero inside that interval [S2]. This distinction determines whether a quoted accuracy applies at a process or ambient temperature.
The operating temperature range is the interval over which the sensor can operate without damage [S5]. A sensor with an operating range of -40°C to 85°C may still be used outside its compensated band only by applying the applicable temperature-coefficient error, and operation above 85°C falls outside the stated operating range [S9].
A complete table should therefore contain both limits, their units, and the condition to which each applies. It should also avoid calling the compensated interval a no-error zone. The defensible wording is “specified accuracy applies from lower limit to upper limit,” with any residual error included in the stated accuracy or total error band [S2].
Build the specification table around measurable errors
One compensated accuracy range can conceal major differences between devices. Three gauges in a 2025 comparison all had a base accuracy of 0.05% FS, yet their compensated ranges were listed as not applicable, 15°C to 35°C, and -10°C to 50°C [S5]. That is a direct warning against comparing accuracy without comparing its valid temperature interval.
Add the sensitivity shift specification to the table, expressed as percentage of full scale per °C. This coefficient defines how the zero and span response change with temperature and must be considered when the sensor operates outside its compensated range [S7].
Record whether the accuracy is referenced to full scale or full-scale span, because the notation must not be treated as interchangeable without the manufacturer’s definition. The Honeywell SSC specification provides an example of a broader total error band, which accounts for combined effects across the compensated range rather than reporting a laboratory-point error alone [S3].
Compare compensation methods by mechanism and evidence

Hardware compensation corrects drift through circuitry during sensor design, while software compensation uses stored calibration data or an algorithm to correct output after measurement [S1]. The SSC Series uses an on-board ASIC and is fully compensated for offset, sensitivity, temperature effects, and nonlinearity over -20°C to 85°C [S3].
Lookup-table compensation can be effective, but its post-compensation accuracy depends on the number of stored calibration points [S1]. A 2024 study found that its RF-IWOA-GRU model reduced pressure standard deviation from 10.18 kPa to 1.14 kPa, while reducing mean absolute error by 75.10% and root mean squared error by 76.15% against the tested baseline methods [S1].
For procurement, passive resistor compensation and model-based digital compensation should not be treated as equivalent. One passive-compensation study reported total accuracy of ±12% FS over its tested working temperature range, demonstrating that a compensation architecture alone does not guarantee a high performance specification [S6].
Accuracy classes and temperature bands need side-by-side review
Use the compensated range, base accuracy, and temperature coefficient as a three-part comparison. In the 0.05% FS example, one gauge added 0.003% FS/°C from 23°C, while another added 0.003% FS/°C over -10°C to 15°C and 35°C to 50°C; the third listed no comparable range and coefficient in the comparison [S5].
These entries produce materially different installed error. The device with no compensated range required the coefficient from its reference condition, while the device compensated from 15°C to 35°C required separate coefficient treatment below 15°C and above 35°C. In the cited comparison, the lack of compensation and inclusion of the temperature coefficient more than tripled the 0.05% FS base accuracy [S5].
For process equipment, also compare sampling and output behavior. The SSC analog output updates at approximately 1 kHz, its digital output at approximately 2 kHz, and it accepts either 3.3 Vdc or 5.0 Vdc single supply [S3]. These electrical and dynamic specifications belong in a selection table because compensation quality cannot compensate for an unsuitable system interface.
Match the sensor to the actual thermal profile

Fixed industrial installations generally require a compensated band that covers the expected process ambient, with the operating range extending beyond it. The CS10 industrial pressure transducer has a stated compensated range of -15°C to 65°C, which is a concrete band that can be compared with a -40°C to 85°C operating range rather than treated as interchangeable [S4][S9].
Board-mount products need an equally specific thermal envelope. Honeywell TBP documentation directs users to tables covering the specified maximum errors within the compensated temperature range, which is the correct place to capture interval-specific limits [S10]. The related pressure sensor selection should also match the sensing technology to the media, pressure range, and installation constraints.
Temperature measurement can be a separate requirement rather than an assumed feature of a pressure device. A dedicated temperature sensor may be needed when the specification requires simultaneous process-temperature correction, traceable temperature logging, or a sensor configuration not provided by the pressure transmitter.
Requirements for industrial and hazardous service
Media compatibility is separate from thermal performance. The SSC Series is intended for non-corrosive, non-ionic gases such as air and dry gases, while optional configurations extend performance to non-corrosive, non-ionic liquids above 40 mbar, 4 kPa, or 20 inH₂O [S3]. A table that lists only pressure span and compensated range is therefore incomplete.
For a field transmitter, verify whether the pressure element, electronics, sealing, and fluid path share one temperature specification. Also check output type, supply voltage, accuracy reference, overpressure rating, and media limits. A pressure transmitter with suitable electrical output does not automatically provide the same thermal or environmental protection as a packaged board-mount sensor.
Where the application includes a calibrated reference instrument, the comparison should use the same temperature interval, accuracy reference, and pressure span. A pressure calibrator can verify the installed output, but it cannot remove a temperature-dependent error unless the calibration process and the sensor specification account for that interval.
Final checks before issuing a purchase specification

Require the manufacturer to state the compensated temperature range in °C, the operating temperature range in °C, the accuracy band, the accuracy reference, the sensitivity or zero-shift temperature coefficient, and the conditions of calibration. Where a device is calibrated by an on-board ASIC, as in the SSC Series, identify that mechanism in the notes rather than using “compensated” as a complete description [S3].
Do not accept a table with a single temperature column unless the device genuinely has one rated interval. At minimum, distinguish the interval where the published accuracy applies from the broader interval where the device can physically operate. A calibrated range of -20°C to 85°C, a laboratory-equivalent 15°C to 35°C band, and a coefficient applied from 23°C represent three different accuracy contracts [S3][S5].
The next procurement action is to populate one row per sensor with compensated range, operating range, accuracy, coefficient, output, supply, and media limits, then flag any installation temperature that falls between the two thermal limits. The output channel and system-level performance also deserve separate review before installation, as covered in Two-Wire Loop Power in a 4-20 mA Pressure Transmitter.