Radiographic testing can reveal porosity, slag inclusions, lack of penetration, and other internal weld defects by recording differential radiation absorption on film or a digital detector.
The practical choice is between an electrically generated X-ray tube and a radioactive isotope source, usually Ir-192 or Co-60, with field access, section thickness, radiation control, and image quality driving the decision.
Choose by wall thickness, access, and control
X-ray equipment provides an adjustable voltage and current, and radiation stops when power is switched off. Gamma sources emit continuously and require shielding, licensed handling, secure storage, transport, and recovery procedures [S4]. Radiographic testing may use X-ray or gamma radiation, with access, wall thickness, and image quality among the factors affecting the choice [S5].
Gamma sources are discrete-energy emitters, while an X-ray tube produces a continuous energy spectrum. Isotopes can therefore be practical when one or a limited number of exposure conditions repeatedly serve the same job, but they do not provide the same exposure adjustment available from an X-ray generator [S3][S8].
Compare the two source options
The comparison below uses four decision criteria that matter in field work: penetration, setup burden, exposure control, and defect orientation. [S3]
Neither source solves every defect-orientation problem. Radiography is strongest for volumetric discontinuities such as gas pores and slag inclusions, while tight cracks and lack of side-wall fusion oriented nearly perpendicular to the beam can be missed. Ultrasonic testing is generally stronger for planar defects that are difficult to reveal radiographically [S5].
Field use cases and operating limits

Use X-ray radiography where the section is within the tube’s practical penetration range, the inspection area has safe electrical access, and the team needs repeated exposure adjustments. This arrangement removes the radioactive-source licensing, transport, storage, and recovery burden, although it does not remove radiation-controlled-area requirements [S4][S5].
Gamma radiography uses radioactive isotopes such as Ir-192 and Co-60, which have characteristic energies and half-lives [S8]. Co-60 is a radioactive isotope used as a gamma-radiation source [S8].
Field exposure geometry still matters. The source and detector must be positioned on opposite sides of the wall, and image sharpness depends on source-to-object distance, object-to-detector distance, source size, film or detector characteristics, and geometric unsharpness. Increasing source-to-film distance can reduce geometric unsharpness, as explained in Reduce Geometric Unsharpness With Source-to-Film Distance.
Image quality is a system requirement
Image quality indicators, exposure charts, film or digital-detector calibration, and viewing conditions must be controlled together. ASME BPVC Section V, Article 2 governs radiographic examination requirements, including image-quality verification and viewing conditions, while ASME Section VIII and API 510 reference radiography for pressure-vessel examination [S3].
Radiographic testing records differential radiation absorption on photographic film or digital detector arrays to detect internal volumetric flaws and planar defects [S3].
For a broader equipment reference, compare the industrial X-ray source category with gamma-camera deployment, detector selection, and controlled-area requirements rather than treating source type as the only decision.
Radiation safety and workflow constraints

Gamma radiography uses radioactive isotopes and requires licensed handling, shielding, secure storage, transport controls, and recovery procedures [S5]. X-ray work also requires radiation safety controls, but the source can be de-energized and it avoids the radioactive-material logistics [S4][S5].
Geometric unavailability and defect orientation affect radiographic results, and cracks or lack of side-wall fusion lying perpendicular to the beam may be missed [S5][S8]. A coating thickness gauge is not a substitute for radiography: it measures a surface coating rather than internal weld discontinuities.
Standards, acceptance, and procurement checks
Radiography produces evidence, not automatic acceptance. A qualified inspector evaluates the radiograph against the governing acceptance criteria, while the examination scope, image-quality requirements, and applicable procedure remain tied to the applicable code and contract [S5].
Before selecting equipment, confirm the required energy range, maximum material thickness, source activity and licensing class for gamma work, detector format, exposure tolerance, IQI sensitivity, viewing requirements, and access geometry. For X-ray systems, verify voltage, current, focal-spot size, duty cycle, cable length, and available mains supply. For gamma systems, verify isotope, source activity, source size, transport container, shielding plan, and recovery arrangements.
The lowest-cost source is not automatically the best source. Choose X-ray for controlled, thin-section work and adjustable exposures; choose Ir-192 or Co-60 for thick or remotely accessed field welds, then control the detector, geometry, IQI, safety zone, and acceptance standard as one complete inspection system.