Flange-mounted ball spline nuts secure the nut with a manufacturer-defined mounting-hole pattern, typically specified by hole count, PCD, and threaded-hole diameter.
The correct pattern depends on the selected nut series, shaft diameter, housing geometry, load direction, and the required perpendicularity and parallelism of the mounting surface.
What a Ball Spline Flange Bolt Pattern Controls
A ball spline combines a grooved shaft with a nut containing circulating ball elements, allowing linear travel and torque transmission in one mechanism [S1]. A flanged nut adds a bolt circle to the housing interface, making the mounting geometry part of the machine's precision and load path.
The flange is not merely a cover or mounting convenience. The accuracy of the mounting surface directly affects the nut's perpendicularity and parallelism, so the housing must be machined to the tolerance required by the selected product [S1]. A flange-mounted ball spline also eliminates the keyed cylindrical-nut housing constraint in many applications, but it does not remove the need to control the support surface.
How Bolt-Pattern Data Is Specified
The shaft and nut model must be selected together; a PCD without the series designation is not a complete installation specification.
The flange pattern is normally transferred to the housing as drilled and tapped holes. Thomson states that a flanged spline nut requires only a rough bore plus drilled and tapped mounting holes, unlike a cylindrical nut that requires a separate key and matching housing keyway [S2].
THK's design checklist treats the spline nut flange mounting hole as a defined interface item, while THK's flange series also shows why the shaft end configuration must be checked separately [S3]. A complete drawing should therefore show at least the nut model, shaft size, PCD, hole quantity, thread specification, housing bore tolerance, and the reference surface used for mounting.
Cylindrical Versus Flange-Mounted Nuts

The main installation choice is between a cylindrical nut secured by a key and a flange nut secured by a mounting-hole pattern. The cylindrical arrangement is more compact, but it requires a keyway in the housing and is more sensitive to housing width and keyway deformation [S4].
The flange arrangement is normally easier to install because the housing receives a rough bore and tapped holes rather than a precision keyway [S2]. It also provides a larger mounting surface for distributing reaction forces, although the actual load capacity still depends on the nut series, ball geometry, preload, and support arrangement. A flange should not be treated as a substitute for a properly stiff housing.
For a ball spline whose primary requirement is linear travel with limited torque, a cylindrical or supported arrangement may be sufficient. For combined linear travel and torsional loading, a flange can simplify installation, but the bolt pattern, housing stiffness, and nut orientation still need to be engineered rather than copied between sizes.
Decision Criteria for the Mounting Pattern
First, match the pattern to the exact manufacturer series and nominal shaft diameter. Nordex identifies the flange type as the MYC-A4 series and provides separate symbols for DF, FW, PCD, and MH, showing that the pattern is model-specific [S5].
Second, check the available housing envelope. A flange requires clearance for the flange diameter, the PCD, fasteners, and the nut body. The housing width and adjacent structure must not interfere with the flange or prevent the shaft from entering the nut. THK identifies flange mounting holes as part of the spline-shaft end-shape checklist, so the end condition should be reviewed with the interface drawing [S3].
Third, check the force path. A flange pattern distributes mounting forces around the nut, while radial loads, moments, and axial reactions are transferred into the housing. The housing material, wall thickness, local ribs, and fastener material all affect the practical result. The ball spline's rated moment and load data should be used for the selected series, not inferred from the flange diameter alone.
Accuracy, Fit, and Alignment

Mounting-surface accuracy is a primary acceptance criterion because it affects perpendicularity and parallelism [S1]. A flat flange face does not correct an out-of-square housing, and a housing with adequate flatness can still lose alignment if the drilled-hole pattern is positioned incorrectly relative to the bore and shaft axis.
This makes the bore-to-flange relationship more than a cosmetic concern: the bore establishes the nut axis, while the flange holes establish how the nut is pulled into that axis.
For a detailed selection framework, compare normal, high, and precision accuracy classes in Ball Spline Accuracy Grades: Normal, High, Precision. The flange pattern should be dimensioned to the same assembly accuracy target as the selected shaft and nut.
Failure Modes and Installation Checks
Three practical failure modes deserve explicit control. First, an incorrect PCD can prevent the fasteners from entering the nut, or allow the nut to sit with edge loading if the housing hole positions are wrong. Second, inadequate housing flatness can preload the flange unevenly, reducing alignment accuracy and increasing friction or binding. Third, insufficient engagement or unsuitable fastener material can reduce joint strength under cyclic moment loading. [S4]
Check the flange face for flatness and burrs, confirm the bore position before drilling the pattern, and use the specified fastener class and thread engagement from the manufacturer drawing. Do not use a substitute bolt pattern simply because the PCD happens to match another nut. The PCD is only one coordinate; hole count, diameter, thread, counterbore or spotface requirements, and the nut's load-rating envelope also have to match.
NB lists lubrication and operating conditions as separate engineering topics, and the mounting arrangement should allow the specified lubricant to reach the nut without blocking the return path [S1]. For flange assembly, verify that the shaft, nut, housing, and fasteners are clean before tightening. Record the final bolt pattern and torque in the assembly documentation so a replacement nut can be installed without guessing the interface.
Applications and Sourcing Requirements

Flange-mounted ball splines are used where a shaft must translate and transmit rotation, including robots, transport equipment, wire winders, and automatic tool-change systems [S4]. The flange is useful in compact housings where machining a long keyway would be inconvenient, but compactness still requires sufficient material around the PCD and behind the nut body.
When requesting a quote or drawing release, specify the manufacturer and series, nominal shaft diameter, nut quantity, PCD, number and size of mounting holes, housing bore tolerance, flange-face datum, and required mounting-surface accuracy. NB offers stainless steel options in SUS440C or equivalent, while SACOM describes 30-degree ground groove contact for its ball-spline design [S1][S4]. Material and contact geometry should be confirmed against the selected series rather than generalized across brands.
A lock nut is not interchangeable with a spline-nut flange bolt pattern. The spline nut's threaded holes secure the flange, whereas a lock nut functions in a threaded adjustment or retention arrangement. Use the exact product drawing and manufacturer installation instructions as the release documents.
The next control point is the housing drawing: verify PCD, hole count, thread callout, bore tolerance, flange-face parallelism, and the mating shaft diameter against the selected series, then record the fastener specification and installation torque in the assembly record.