NRC and CAC describe different acoustic jobs: NRC rates absorption within a room, while CAC rates airborne sound transmission between adjacent rooms through a shared ceiling plenum [S2][S3].
The ratings use different scales and test bases, so they cannot be added or treated as interchangeable: NRC runs from 0 to 1, whereas published CAC guidance places the ceiling-system range at approximately 25–45 [S1][S2].
What NRC and CAC Measure
NRC, or Noise Reduction Coefficient, expresses the average sound-absorption performance of an acoustic product on a scale from 0 to 1. An NRC of 0.50 represents approximately 50% absorption, with the remainder reflected rather than absorbed [S1]. NRC is measured by ASTM C423 and addresses reflected sound, reverberation, speech clarity, and acoustic comfort within the occupied space [S2][S3].
CAC, or Ceiling Attenuation Class, addresses the separate transmission path from one room, through its suspended ceiling and shared plenum, and into an adjacent room [S3]. CAC measures a tested ceiling system's resistance to airborne sound transmission between adjacent enclosed spaces sharing a plenum, so it should not be treated as a complete guarantee of room isolation [S4].
One concise distinction is useful in a specification: NRC controls echo inside the room, while CAC controls leakage to the room next door [S2]. Neither rating alone describes every path through doors, partitions, glazing, ducts, lighting, or mechanical equipment [S4].
Selection Criteria and Typical Values
For an echo problem, specify NRC to suit the room's speech and reverberation requirements. Most good commercial ceilings have NRC ratings between 0.50 and 0.90 [S2]. These are selection targets rather than universal regulatory minima.
For speech privacy, specify CAC against the room adjacency and intended confidentiality. CAC ratings range from 25 to 50, with 30 and above considered good [S1].
Material construction is the practical trade-off. Soft, porous materials generally improve NRC, while heavier and denser construction generally improves CAC. Soft materials tend to improve NRC, while heavier construction tends to improve CAC [S1]. A specification should therefore set separate NRC and CAC thresholds and identify the tested product configuration.
CAC vs NRC Decision Matrix

Compare the ratings against the actual acoustic objective, not against each other. NRC is measured on a 0–1 absorption scale, while CAC is a numbered ceiling-system attenuation class typically shown from 25 to 45 [S1][S2].
For cost and installation effort, a tile change may be simpler than rebuilding the plenum, but replacing panels alone may not address doors, partitions, or other leakage paths [S4]. For appearance, mineral-fiber, metal, or other systems can be compared by NRC, CAC, grid compatibility, and tested assembly rather than by a broad “acoustic tile” description [S4].
For lifetime and maintenance, record the product identity, approved substitutions, installation references, and access requirements so that replacement panels retain the intended acoustic performance [S4]. A high NRC value does not compensate for low CAC, and a high CAC value does not correct excessive reverberation inside the room [S2][S10].
Room-Type Recommendations
Use NRC as the primary criterion for open-plan offices, classrooms, call centers, conference spaces, waiting areas, and transportation interiors where reflected sound reduces speech clarity or increases perceived noise [S3]. Published target ranges include NRC 0.70+ for open offices and classrooms, with 0.50–0.90 identified as a common commercial range [S2].
Use CAC as the primary criterion for private offices, exam and consultation rooms, interview rooms, enclosed meeting rooms, and other enclosed spaces where conversations must not reach neighboring rooms [S3][S5]. For spaces requiring both benefits, identify both targets in the ceiling specification and verify them against the actual tile, grid, plenum, and installation details [S4].
CAC is not suitable as a general replacement for STC because STC addresses wall and partition transmission while CAC addresses a ceiling-and-plenum route [S8]. A privacy-critical room should have its partitions, doors, glazing, and ceiling reviewed as one transmission strategy rather than relying on a tile label alone [S4].
Limitations, Installation, and Failure Modes

CAC performance depends on the installed ceiling system, including tile and grid selection, panel orientation, perimeter conditions, and shared-plenum construction. Changing a tile without maintaining the tested assembly can invalidate the basis of the published rating [S2][S4].
Common failure modes include specifying high NRC for a privacy room, specifying high CAC for a reverberation-controlled classroom, using a generic “acoustic tile” description, and overlooking open doors, glazing, ducts, or partitions that stop below the plenum [S3][S4]. The ceiling specification should define which room concern each rating is intended to solve.
Field performance may differ from laboratory ratings, so if field verification is required, define the evaluation method and responsible party before construction. The closeout record should retain product data, installation references, substitutions, and any agreed field results [S4].
Sourcing and Specification Record
Request NRC absorption data under ASTM C423 and CAC system data associated with ASTM E1414 and E1111, then confirm that the cited reports apply to the proposed product and configuration [S2]. Treat CAC as a system rating and NRC as a product absorption rating rather than converting one scale into the other [S1][S2].
For coordinated suspended ceiling work, record room use, observed problem, NRC target, CAC target, existing partitions, shared-plenum conditions, selected panel, grid compatibility, installation documents, maintenance access, and substitution approval [S4]. This converts two headline numbers into a traceable engineering decision.