Specify UNS S32205 Duplex 2205 at PREN 34–37 for general industrial chloride service, and UNS S32750 Super Duplex 2507 at PREN 40–45 when seawater, crevice attack, or high-temperature chloride exposure dominates the risk.
Both grades provide a ferritic-austenitic structure, high strength, and resistance to chloride stress-corrosion cracking, while 2507 has higher chromium, molybdenum, and nitrogen content [S1][S5].
PREN decision criteria for duplex selection
The Pitting Resistance Equivalent Number is calculated as PREN = %Cr + 3.3 × %Mo + 16 × %N, using the material composition [S3]. Duplex 2205 normally spans PREN 34–37, while Super Duplex 2507 spans 40–45; one guide defines super duplex as PREN above 40 [S1][S3][S5].
PREN is a ranking aid for pitting resistance, not a complete corrosion allowance. Grade selection must still consider chloride concentration, temperature, crevices, oxidising chemicals, fabrication condition, and weld procedure. For seawater and other aggressive chloride service, use the material certificate to verify the actual PREN rather than relying on the grade designation alone.
The broad decision rule is practical: 2205 is the general-purpose choice for moderate chloride exposure, while 2507 is the safer corrosion-performance choice for seawater, brine systems, subsea equipment, and hot chloride service [S1][S5].
Composition and mechanical-property comparison
UNS S32205 typically contains 22.0–23.0% chromium, 4.5–6.5% nickel, 3.0–3.5% molybdenum, and 0.14–0.20% nitrogen. UNS S32750 raises these intervals to 24.0–26.0% chromium, 6.0–8.0% nickel, 3.0–5.0% molybdenum, and 0.24–0.32% nitrogen [S3].
Reported minimum mechanical properties show the strength trade-off clearly: 2205 has yield strength of at least 450 MPa and tensile strength of at least 620 MPa, whereas 2507 has yield strength of at least 550 MPa and tensile strength of at least 800 MPa [S5]. Elongation is lower for 2507, at 15–25%, compared with 25–30% for 2205 [S5].
On strength, 2507 can permit lower section thickness only after pressure, fatigue, buckling, corrosion allowance, and fabrication code checks. Its approximately 22.2% higher minimum yield strength does not justify thinning a pressure component without completing the required calculations [S5].
Application fit and failure exposure

Duplex 2205 is suitable for chemical tanks, pressure vessels, heat exchangers, pulp-and-paper equipment, offshore auxiliary piping, and the freshwater side of desalination plants [S3][S5]. Super Duplex 2507 targets seawater systems, desalination brine and reject circuits, subsea pipelines, wellheads, marine heat exchangers, high-pressure seawater injection, and flue-gas scrubbing equipment [S3][S5].
The more detailed 2205-versus-316L comparison covers chloride concentration and seawater-service limits for that selection boundary.
Failure modes differ by operating condition. A high PREN does not eliminate crevice corrosion in a tight joint, pitting beneath deposits, or attack by oxidising acids. Conversely, selecting 2507 for a mild freshwater system may add unnecessary material and welding cost without improving the controlling service factor. Duplex materials also need protection within their applicable temperature range, because excessive temperature can promote undesirable phase formation [S3].
Cost, fabrication, and welding implications
That premium can still be justified where reduced corrosion risk extends equipment life, but it should be compared against inspection, weld-control, machining, and replacement consequences.
Both grades require heat-input and interpass-temperature control to preserve the intended duplex microstructure. Super Duplex 2507 generally needs matching filler metals and tighter process control, and its susceptibility to intermetallic phase formation during cooling increases the importance of qualified welding procedures [S1][S3][S5].
Fabrication planning should include heat-input records, interpass temperature, filler-metal certification, pickling or passivation, and post-weld inspection. The duplex 2205 reference provides the base-grade context, while production weld procedures should be validated for the selected product form, thickness, and service temperature.
Procurement and standards verification

Specify the UNS grade, dimensional product standard, material condition, heat treatment, and applicable certification rather than writing only “duplex.” The common designations are UNS S32205 for 2205 and UNS S32750 for 2507, while EN 1.4462 is associated with 2205 and EN 1.4410 with super-duplex grades [S1][S4][S6].
Verify composition from the material certificate and calculate PREN from certified values. Confirm the specified minimum PREN, chloride concentration, temperature, pressure, and welding requirements in the purchase specification. The duplex-family overview identifies 2205 as EN 1.4462 and describes super-duplex PREN as approximately 38–45 [S4][S6].
Do not accept a supplier statement such as “super duplex” without confirming the grade and test report. Published commercial comparisons give 2507 PREN values of approximately 40–45 and 2205 values of approximately 34–37 [S1][S3][S5], so a certificate outside the agreed grade requirement requires technical review before release.
Explicit selection recommendations by service
Choose 2205 when the service contains moderate chloride exposure, the operating corrosion risk is dominated by standard industrial chemicals, and fabrication capability is limited to conventional duplex procedures. It offers PREN 34–37, yield strength of at least 450 MPa, tensile strength of at least 620 MPa, and better ductility and workability than 2507 [S3][S5].
Choose 2507 for natural seawater, desalination brine and reject service, subsea or offshore equipment, hot chloride service, or crevice-prone systems where corrosion is the governing design constraint. It provides PREN 40–45, yield strength of at least 550 MPa, and tensile strength of at least 800 MPa, at typically 30–50% higher material cost and tighter fabrication control [S2][S3][S5].
The final decision should be recorded against four measurable criteria: minimum certified PREN, maximum service temperature and chloride concentration, applicable mechanical design requirements, and total installed fabrication cost. If one criterion cannot be demonstrated, select the higher-PREN grade for further corrosion assessment rather than treating nominal grade labels as proof of suitability.
Track two procurement signals before ordering: the certified heat chemistry supporting the agreed PREN, and the approved welding procedure with its heat-input, interpass-temperature, filler-metal, and intermetallic-phase controls [S1][S3][S5].