A scanner specified at 0.02 mm + 0.03 mm/m has a nominal maximum error of 0.02 mm at zero range, increasing by 0.03 mm per metre of measurement volume.
At a 1 m measurement span, the calculated limit is 0.05 mm; at 2 m, it is 0.08 mm. These are scanner-system specifications, not automatic guarantees of inspected-part conformance.
What the two-term accuracy formula means
Volumetric accuracy is commonly written as a fixed term plus a distance-dependent term, such as 0.02 mm + 0.03 mm/m. The fixed term describes baseline error, while the second term accounts for dimensional growth over the scanned volume [S2][S8].
The formula is additive. For a 2 m measurement span, the stated error is calculated as 0.02 mm + (0.03 mm/m × 2 m), giving 0.08 mm.
This measurement applies to global dimensional performance across a measurement volume, unlike single-scan accuracy, which describes a local measurement area. Long scan paths, incomplete registration, insufficient markers, unstable tracking and weak surface geometry can all increase accumulated error [S4].
Accuracy, resolution and repeatability are different
Accuracy describes closeness to a known reference value, resolution describes the smallest detectable change in the measured quantity, and repeatability describes consistency when the same feature is measured repeatedly [S1][S3]. A scanner can be repeatable while retaining a consistent bias, so precision and trueness cannot be substituted for one another.
One published handheld specification lists 0.015 mm accuracy and 0.020 mm resolution separately, with volumetric accuracy of 0.015 mm + 0.03 mm/m in standard mode [S1]. Another metrology scanner is listed at 0.02 mm single-scan accuracy and 0.02 mm + 0.03 mm/m volumetric accuracy [S6].
For example, a titanium bracket with a ±0.05 mm profile tolerance requires more than a headline “0.02 mm” claim. The engineer must compare the complete volumetric specification with the tolerance, measurement volume and full inspection uncertainty, rather than treating the two terms as interchangeable [S1].
Compare measurement scopes against four criteria

Single-scan accuracy is useful for a small, locally measured feature, but it does not establish the accuracy of a stitched model covering a larger object. Volumetric accuracy is the more relevant criterion for dimensional inspection, reverse engineering and large-part comparison [S4][S5].
Resolution remains a separate selection criterion because it determines whether shallow scratches, small radii and fine edges can be detected. Point spacing alone does not establish dimensional accuracy, and accuracy alone does not establish whether every small feature was resolved [S1][S3].
Use the formula against real inspection limits
At a 100 mm span, 0.02 mm + 0.03 mm/m gives a calculated limit of 0.023 mm. At 500 mm it gives 0.035 mm, while a 1 m span gives 0.05 mm and a 5 m span gives 0.17 mm. The proportional term therefore becomes more consequential as the measured object grows [S2][S3].
Another handheld scanner is specified at 0.04 mm + 0.06 mm/m, which produces 0.10 mm at 1 m and 0.16 mm at 2 m [S5].
That comparison matters for purchasing. A lower fixed accuracy does not guarantee superior performance across a large volume if its distance coefficient is higher. Compare the formula at the largest expected measurement span, not the first number printed on a sales sheet.
Control drift with workflow controls and qualified evidence

A known-length scale bar can provide a dimensional constraint that helps reduce scale drift during large-range scanning. Combining it with markers, adequate overlap and stable tracking gives the registration process better geometric control than relying on local scan precision alone [S4].
Independent laboratory evidence also matters. Guidance for scanner selection recommends third-party-validated volumetric accuracy and laboratories accredited to ISO/IEC 17025 or CNAS accreditation, rather than relying only on a manufacturer’s headline single-frame figure [S5].
Fit the scanner to the decision, not the headline
This performance class is appropriate for dimensional comparison of small precision components, tooling and localized aerospace features when the calculated volumetric error remains compatible with the tolerance. It is less suitable for pass/fail decisions on long or large structures without additional scale control, registration controls and uncertainty assessment [S1][S4].
Over-specifying adds acquisition time, cost and workflow complexity without improving the inspection decision. Under-specifying risks producing a model that looks complete but lacks dimensional credibility, particularly where the length term accumulates across multiple scan positions [S3][S4].
For a 0.02 mm + 0.03 mm/m specification, the defensible acceptance test is numerical: calculate the limit at the actual scan span, add the relevant workflow and measurement uncertainties, and compare the resulting decision risk with the drawing tolerance. Track two signals through verification: the registered deviation between scan and certified artifact, and the scan span at which the calculated error approaches the tolerance limit.