Procurement directory
Shielded Cable Manufacturers
Compare the documented product facts shown for each cited route before opening a dossier. A missing dimension remains absent rather than being inferred from a related series.
- Coverage
- 10 canonical company dossiers
- Compare here
- Product range, product facts and selection scope
- Evidence basis
- Official product routes retained per category
Source-bound comparison
Compare documented product facts
Each cell repeats only the product facts retained for that company’s category evidence. Open the dossier for the source note and evidence boundary.
| Manufacturer | Flame / recognition | Service temperature | Material | Standard |
|---|---|---|---|---|
| Amphenol TPC Wire & Cable | UL Recognized | -40°C | — | — |
| Cicoil, LLC | UL 94V-0 | -104°C | — | — |
| HELU KABEL GmbH | — | — | — | — |
| igus SE & Co. KG | — | +5 °C | — | — |
| NKT A/S | — | +90°C | aluminium | — |
| Polycab India Limited | — | — | — | IEC 60227-7 |
| Prysmian Cables and Systems USA, LLC | — | 18°C | — | — |
| SAB Bröckskes GmbH & Co. KG | — | — | — | — |
| TKD KABEL GmbH | — | — | — | — |
| Top Cable S.A. | — | — | — | EN 50525 |
-

Amphenol TPC Wire & Cable
Documented seriesTrex-Onics Overall Shielded Continuous Flex Multi-Conductor Cable
- Electrical and temperature
- The exact page lists 600 V and a 105 degrees C maximum conductor temperature.
- Bend radii
- It publishes static and dynamic bend radii of 6 x and 8 x cable outside diameter.
- Selection scope
- Compare conductor configuration, shield, voltage, temperature and dynamic bend radius before selection.
-

Cicoil, LLC
Documented seriesCicoil Shielded Signal High Flex Cable
- Shield and cycle rating
- The page specifies twisted shielded signal pairs for EMI/RFI protection and a nominal 10,000,000-cycle flex life.
- Continuous-motion bend radius
- It lists continuous-motion bend-radius options from 1.2 to 2.1 inches.
- Selection scope
- Compare pair count, EMI/RFI requirement, bend radius and continuous-flex motion envelope before selection.
-

HELU KABEL GmbH
Documented seriesHELU MULTISPEED-TRONIC-C-PUR screened cable
- Screened motion duty
- The page describes a screened PUR cable for data and signal transmission in continuous drag-chain operation.
- Installation environment
- It states suitability for dry, moist, wet and outdoor installation, including long travel paths.
- Selection scope
- Compare screening, conductor configuration, travel length, bend radius and outdoor requirements before selection.
-

igus SE & Co. KG
Documented seriesigus chainflex CF140US shielded control cable
- Shield and jacket
- The page identifies CF140US with a braided shield and an oil-resistant PVC jacket.
- Example and motion limits
- CF140US.05.02 is 2 x 20 AWG; the series lists 10 x diameter minimum e-chain bend radius and +5 to +80 degrees C.
- Selection scope
- Compare conductor variant, braided shield, oil exposure, bend radius and e-chain temperature range before selection.
-

NKT A/S
Documented seriesNKT N-A2XS(F)2Y screened medium-voltage cable
- Voltage rating
- The cited product lists a 21/36 kV rating and a 73 kV test voltage.
- Screen and water blocking
- It specifies an aluminium conductor, screen, PE outer sheath, and longitudinal and radial water blocking.
- Selection scope
- Compare conductor cross-section, screen and water-blocking construction against the 21/36 kV system requirements.
-

Polycab India Limited
Documented seriesPolycab 110 CY screened control cable, product 54824
- Rating and standard
- The exact page lists 300/500 V AC and construction generally conforming to IEC 60227-7.
- Screened construction
- It specifies multicore copper conductors, PVC insulation and inner sheath, ATC wire braid and transparent PVC outer sheath.
- Selection scope
- Compare core count, conductor section, braid screen, voltage rating and IEC 60227-7 requirements before purchase.
-
Prysmian Cables and Systems USA, LLC
Documented seriesPrysmian CUBOND copper-shield control cable
- Conductors and shield
- The cited page specifies XHHW-2 conductors in 14, 12 and 10 AWG with a copper shield and CPE jacket.
- Installation scope
- The page states cable-tray, direct-burial and aerial installation scope.
- Selection scope
- Compare conductor count and gauge, copper-shield construction, jacket option and installation method before purchase.
-

SAB Bröckskes GmbH & Co. KG
Documented seriesSAB S 910 CP shielded handling cable
- Screened construction
- The construction table specifies a tinned-copper overall braid screen, TPE insulation and a PUR outer sheath.
- Voltage and bend radius
- The page lists U0/U 0.6/1 kV and a continuously flexible minimum bend radius of 7.5 x cable diameter.
- Selection scope
- Compare conductor size, braid screen, voltage, PUR environment and continuous-flex bend radius before selection.
-

TKD KABEL GmbH
Documented seriesTKD KAWEFLEX 7240 SK-C-TPE shielded cable, item 1703444
- Electrical construction
- The product data identifies a shielded TPE power and control cable with a 1 kV IEC rated voltage.
- Moved bend radius
- The exact item lists a moved minimum bending radius of 5 x cable diameter.
- Selection scope
- Compare conductor set, screen, voltage, moved bend radius and drag-chain duty against exact item 1703444.
-

Top Cable S.A.
Documented seriesSCREENFLEX 110/200 LiYCY VC4V-K screened control cable
- Application
- The cable is documented for control circuits, electronics and computer-system connections.
- Voltage range
- The page lists 300/500 V through 1.5 mm2 and 0.6/1 kV from 2.5 mm2.
- Selection scope
- Compare conductor section, voltage rating, screen construction and installation environment before selection.