Select the cartridge by calculating resin volume per hole, then divide the project requirement by usable yield; an 8.6 oz cartridge contains 254 ml, while larger systems include 380 ml and 750 ml packages [S4][S7].
Cartridge volume does not directly determine the number of anchors, because hole diameter, embedment depth, anchor geometry, waste, nozzle losses, and curing temperature change the resin consumed per installation [S2].
Calculate the number of anchors from hole volume
Use the required hole geometry, not the cartridge label, to estimate material demand: hole diameter is typically 1/8 in (3 mm) greater than the anchor diameter, and hole depth is typically nine times the anchor diameter [S4]. The calculated annulus volume is the starting point, but the manufacturer’s stated fill volume remains the controlling value because the hole may not be filled to its geometric top.
For example, a 5/8 in threaded rod installed in a 3/4 in hole to a 5-5/8 in embedment has a gross cylindrical hole volume of about 18.3 in³, or 300 ml. That figure is not a cartridge-yield rule: the QUIKRETE installation instruction calls for dispensing enough adhesive to fill the hole after insertion, while its 254 ml cartridge is not stated as the number of anchors produced by that geometry [S4].
Do not estimate the number of installations from net cartridge volume alone. A practical estimate is: usable resin per cartridge divided by calculated resin per hole, then round down. Replace that estimate with the manufacturer’s volume calculator or technical data for the selected resin, anchor diameter, hole diameter, and embedment depth [S1][S2].
Compare cartridge sizes by yield and job scale
The available packages cover very different installation scales: QUIKRETE High Strength Anchoring Epoxy is supplied in an 8.6 oz, 254 ml cartridge [S4]; Ramset ChemSet 101 PLUS is listed in 380 ml and 750 ml cartridges, part numbers C101C and C101J [S7]. These sizes do not establish a universal anchors-per-cartridge figure because product formulations and anchor-hole requirements differ.
Use the package comparison below to organize the decision:
QUIKRETE High Strength Anchoring Epoxy is supplied in 254 ml cartridges, while Ramset ChemSet 101 PLUS cartridges are available in 380 ml and 750 ml sizes [S4][S7].
Match resin to concrete, load, and installation conditions

Cartridge size does not establish anchor suitability. Hilti’s adhesive range separates systems for cracked and uncracked concrete, lightweight concrete, grout-filled masonry, hollow masonry, and unreinforced masonry, with some products approved for seismic, fire, submerged, or water-filled installations [S1].
The chemical anchor must also match the base material and design load. For example, the QUIKRETE 254 ml epoxy is described for concrete and masonry, including grout-filled block and unreinforced masonry, but excludes overhead anchoring and sustained long-term loads [S4]. Its published test condition uses a 5/8 in threaded rod in a 3/4 in hole, embedded 5-5/8 in in 3,500 psi concrete, cured for 24 hours at 75 °F [S4].
Cartridge selection should therefore follow four checks: substrate, approval report, required embedment, and cure temperature. If a project involves chemical exposure or incompatible metal contact, review the resin formulation before ordering. The cartridge size changes logistics, not the chemical compatibility of the cured bond.
Account for installation losses and curing constraints
Allow for resin used in the mixing nozzle and discarded at the start of dispensing. QUIKRETE instructs the installer to gun out material until the color is uniform; its mixing nozzle begins hardening in approximately 20 minutes if unused [S4]. A partially used cartridge therefore has less usable yield than its printed volume.
Temperature directly affects the loading schedule. QUIKRETE states a minimum 4-hour undisturbed cure at 25 °C, longer curing at lower temperatures, and full strength at 24 hours at 25 °C. Its reported 24-hour ultimate pullout value is 124 kN in the stated test condition, while the value at the 4-hour minimum load time is 31 kN [S4]. The manufacturer then applies a 75% reduction to the 24-hour ultimate value for allowable load, producing a 31 kN allowable example.
For the cited QUIKRETE product, the application limit is explicit: it is not for overhead anchoring and not for sustained long-term loads [S4]. These limits can eliminate an otherwise convenient cartridge and should be checked before calculating material.
Prepare holes consistently before counting cartridges

Accurate material planning depends on consistent hole preparation. Rawlplug requires drilling 1 cm deeper than the specified anchorage depth and recommends the 4x4x4x cleaning sequence: four pump strokes, four brush passes, and four further pump strokes [S5]. The hole must be larger than the rod diameter, and drilling method must suit the substrate.
For QUIKRETE, the preparation specification calls for a hole diameter typically 1/8 in (3 mm) greater than the anchor diameter, a hole depth typically nine times anchor diameter, and a minimum recommended hole depth of 1 in. Dust must be removed by repeated brushing and blowing, and standing water is not permitted [S4].
Hole volume also affects edge and spacing constraints. For the cited 5/8 in and 3/4 in LDT anchors, the critical edge distance is 10 times the anchor diameter, equivalent to 6.25 in for 5/8 in and 7.5 in for 3/4 in [S3]. Reduced edge distances can require a different design treatment, so a drawing may specify both anchor count and geometry that a simple cartridge calculation will miss.
Select the correct chemical anchoring system
Use expansion anchors when a mechanical anchor is technically suitable and the specification permits it, because they avoid resin cure time. Use chemical anchors when the design requires rebar dowels, irregular geometry, high loads, cracked concrete approval, or a bonded connection to a threaded rod, provided the resin system has the required approval [S1][S2].
Do not use a chemical anchor simply because it offers higher nominal capacity. Hilti’s product range includes injectable mortar, foil capsules, and dual-action adhesive systems, including one approved for base-material temperatures from -18 °F to 104 °F [S1]. The selected system, not the cartridge volume, governs permitted base materials, temperature range, installation method, and certification.
Build the final cartridge shortlist

Choose the 254 ml cartridge when the verified anchor geometry fits the product’s specified fill volume and the installation meets its load and orientation limits. Choose 380 ml for medium batches and 750 ml for larger repeated installations, provided the manufacturer’s technical data confirms equivalent resin performance and cure requirements [S4][S7].
The shortest route to a defensible order is: obtain the product-specific resin volume per anchor, multiply by the number of holes, add measured waste, select the package with adequate yield, and verify approval, cure time, and base-material conditions [S1][S2]. A chemical anchor volume calculator or the manufacturer’s own selector can then replace the preliminary estimate with a project-specific count.
Track the approved anchor count, hole diameter, embedment depth, nominal and usable cartridge volume, and calculated anchors per cartridge in the installation record. If any field value changes, recalculate the cartridge requirement before opening the next package.