Choose a power cord assembly by matching its plug, voltage, current, conductor size, length, environment, and approvals to the equipment and local supply.
A suitable assembly may be a mains power cord, detachable cord set, accessory jumper, or connector power cord, depending on how the equipment is installed and powered.
Define the Connection and Supply
The first selection point is the connection architecture, not the cable jacket. Terms such as detachable or non-detachable cord, appliance cord, cable, cable assembly, interconnection, power supply, power cord, cord set, jumper cord, and connector power cord may refer to the same product.
Jumper cord is one of the terms that may be used for the means of connecting electrical equipment to a power source. Cord set is one of the terms that may be used for the means of connecting electrical equipment to a power source. This distinction determines who supplies the mating receptacle and whether the assembly presents an unprotected termination that should not remain accessible.
Record the equipment nameplate data before selecting a cable: AC or DC input, rated voltage in volts, frequency in hertz, current in amperes or power in watts, conductor count, and equipment class. The plug must match the outlet in the destination country, and its physical similarity to another plug does not establish compatibility [S1].
For detachable equipment, the inlet connector must also match the appliance. A C14 inlet mates with a C13 cord connector; the C13 is female and the C14 is male [S3]. For broader cable-selection context, compare power cable construction and conductor sizing rather than judging an assembly by its plug alone.
Match Voltage, Current, and Conductor Size
The cord's voltage rating must equal or exceed the equipment input rating, and its current rating must equal or exceed the equipment's rated draw [S5]. Where only wattage is published, current can be calculated as watts divided by volts; for example, 3,600 W at 240 V equals 15 A [S5].
Wire gauge controls conductor cross-section and current-carrying capacity. A lower AWG number identifies a thicker conductor, so higher-current and longer installations generally require a lower gauge number.
Do not select the plug rating independently of the conductors. A 3 A power supply can operate on a cord marked 10 A or 15 A, provided the plug, connector, cable, length, voltage, and environmental ratings all satisfy the application [S3]. Conversely, a thicker cord does not correct an inadequate plug, connector, insulation, or termination.
The exact permissible current still depends on the complete rated assembly, installation conditions, and applicable approval, so the device specification remains the controlling document.
Compare Common Assembly Forms

Three practical forms cover most equipment-level and replacement purchases: a detachable mains cord set, an exposed-conductor power cord, and an accessory jumper cord. Each form differs in termination, serviceability, and application rather than in the basic need to match voltage and current. [S1]
The C13/C14 example demonstrates the selection risk: identifying the device inlet as C14 does not mean the cable must also terminate in C14 [S3]. For permanent installations, the bare-conductor arrangement gives the installer control over termination; for field-serviceable products, the detachable cord set is usually cleaner.
Set Length and Installation Route
Cord length should satisfy the measured distance between the equipment and outlet while avoiding both reach failure and excess cable that creates a trip hazard [S5]. Do not select length before reviewing conductor gauge, because voltage drop and permissible current over longer distances can force a heavier conductor.
For extension applications, determine whether the cord is the final connection or part of a temporary distribution arrangement. Extension cords should not create an avoidable high-resistance link between the equipment and supply. This is particularly relevant where an equipment cord is specified at 3 A and the proposed extension is already at or near its current rating.
Record the route, not merely the straight-line distance. Include service loops, bend clearance, connector space, movement, and the distance needed to route without kinking or pinching. If the final installation is fixed and the distance is known, a custom assembly can avoid excess length, but the final routing must be confirmed before the conductors are terminated.
Qualify the Operating Environment

Indoor, outdoor, generator, and industrial duties need different levels of ingress, impact, chemical, and temperature protection. Outdoor assemblies exposed to rain, snow, abrasion, or chemicals require cable and connectors specifically qualified for that environment, rather than an indoor cord fitted with a weather-resistant plug [S4].
These are model-specific examples, not universal ratings for all STW, Type W, RV, or generator cords.
For outdoor generator connections, NEMA 3R connectors are one documented selection [S4]. Verify the complete assembly, including the plug, receptacle, cable, and any manufacturer-specific claim, rather than assuming a weather-resistant connector makes the complete cord suitable for wet locations.
Do not choose the mainstream household cord for a mobile industrial, generator, or outdoor application. The mainstream option is generally acceptable for an indoor, dry-location appliance with a modest load. It is a poor match when the cord will encounter moisture, chemicals, abrasion, high ambient temperature, frequent handling, or a high-current load.
Check Standards, Labels, and Finishing
The finished cord must satisfy the safety requirements for the equipment class and destination market. Certain equipment, including medical devices, requires a power cord that meets the relevant safety standards and certifications [S5]. Verify the mark on the complete assembly rather than treating the cable jacket, plug, and connector as independently interchangeable approvals.
For products assembled by a manufacturer, require the plug type, cord rating, conductor count, gauge, length, connector type, insulation material, and country or market marking to be identifiable. Selection considerations also include end finishing, cord-set put-up, insulation material, conductor material, gauge, voltage, and temperature [S7]. These details affect installation, service, and resistance to damage.
IEC 60320 Sheet E and Sheet I are relevant connector identifiers for jumper applications, while C13 and C14 describe a mating connector and inlet combination [S1][S3]. The terminology is not interchangeable: a cord set, connector power cord, and jumper cord set have different termination arrangements and should be specified separately.
For a broader view of industrial cable construction, including conductor and insulation decisions, see Power Cable Advantages, Disadvantages and Selection Criteria. Keep the final purchasing record tied to the equipment datasheet, cord marking, destination plug, and measured installation conditions.
Apply a Final Selection Checklist

A release-ready assembly needs 10 confirmed items: plug type, connector or termination style, rated voltage, rated current, conductor gauge, conductor count, length, temperature range, environmental exposure, and required safety approval. If any one is unknown, the assembly is not yet specified. [S5]
Use this shortlist logic: choose a detachable cord set for serviceable equipment with a matching inlet; choose a power cord with exposed conductors for controlled internal termination; choose a jumper cord for accessories powered from another device; and choose a heavy-duty, outdoor-rated assembly for generator or industrial service.
The verification record should show the equipment rating, local voltage and frequency, calculated current where wattage is given, selected AWG, measured route length, plug and connector mating codes, environmental limits, and the complete assembly's approval label [S2][S3][S5].
Before purchase, compare the proposed assembly against the original equipment specification and the replacement cord's printed ratings. Reject any candidate that fails on plug compatibility, voltage, current, conductor size, connector fit, environmental exposure, or certification, regardless of its physical appearance.