Dynamic compaction PPV cannot be predicted reliably from hammer mass alone because drop energy, distance, soil profile, damping and equipment transfer efficiency all affect the measured peak particle velocity.
The workable method is a site-specific scaled-distance or attenuation calculation, supported by a monitored test drop, with PPV measured at the structure or receptor before production impacts begin.
Dynamic compaction produces transient ground vibration
Dynamic compaction is a transient vibration source: each falling weight applies an impact, and the resulting ground motion then decays through energy dissipation [S2]. This differs from vibratory compaction, which produces a sustained or steady-state signal [S2]. That distinction matters because a single drop can create a sharp velocity peak without resembling the waveform from a continuous vibrator.
Ground vibration travels predominantly as Rayleigh surface waves, with body waves including shear and compressional components contributing at lower levels [S2]. Rayleigh-wave dominance matters because the particle-motion direction and attenuation vary with depth and distance. A sensor set only on one horizontal axis can therefore miss the true three-axis PPV or misclassify the dominant direction of motion.
Dynamic-compaction field observations have found vibration frequencies commonly between 5 and 40 Hz [S5]. The peak response is a function of impact energy and site response, so a site-specific frequency check is necessary before applying a generic distance law. Coincidence between the source frequency and a soil-layer or structure frequency can amplify ground motion and structural response [S1].
Select a prediction model with the right energy term
The standard screening approach relates PPV to scaled distance, commonly expressed as distance divided by the square root of applied energy [S3]. Dynamic compaction is an impact process, so the energy term should represent the delivered impact energy rather than only the hammer weight or nominal potential energy. Drop height and mass must be converted consistently into energy units before applying a published coefficient.
Published deep-vibro data show why machine-specific calibration matters. Weng et al. evaluated nearly 1000 field measurements across multiple vibro-replacement and vibro-compaction sites in Southeast Asia [S4].
Three options should be compared for a trial program. An energy-distance law is fast for screening, but it depends on transfer efficiency and soil response. A physically informed attenuation model includes geometric spreading and material damping, but needs defensible damping values. A monitored calibration approach produces the strongest site evidence, because it captures the actual hammer, drop height, ground profile and measurement geometry.
Compare prediction methods by accuracy and effort

For dynamic compaction, scaled-distance screening is strongest on calculation speed and weakest on site specificity. A physics-based model improves the treatment of distance attenuation but still depends on calibrated damping and transfer assumptions [S4]. Trial-drop monitoring provides direct PPV observations, requires access to instruments and a controlled first impact, and gives the clearest basis for adjusting production work.
Empirical pile-driving equations should not be treated as a direct substitute for dynamic-compaction calibration. Svinkin identifies empirical methods as producing vertical peak amplitudes with insufficient accuracy because they do not fully account for site heterogeneity and spatial variation in soil properties [S1]. Dynamic compaction also has repeated impacts, variable contact conditions and a falling-weight system that does not necessarily transfer all nominal potential energy into the soil.
Where transfer efficiency cannot be measured directly, retain separate variables for drop mass, drop height and the energy actually entering the ground. Do not collapse a variable machine energy into an arbitrary constant, because the reviewed vibro-compaction data produced physically unrealistic predictions for some equipment combinations when vibrator characteristics were inadequately represented [S4].
Use attenuation with damping for a field estimate
Existing predictive models for ground vibrations from deep vibro-techniques were evaluated against field data, and a semi-empirical approach was developed to better capture their attenuation with distance [S4].
Weng et al. drew on close to 1000 field measurements across multiple vibro-replacement and vibro-compaction sites in Southeast Asia [S4]. This is evidence for deep vibro techniques rather than a universal drop-impact value for dynamic compaction. It can inform an initial sensitivity range, but it should not replace a dynamic-compaction trial where sensitive receptors are nearby.
Prediction distance must be defined consistently. Use the horizontal distance from the impact point to the monitoring location, and keep the same distance convention when comparing site data with model coefficients. Plot measured PPV against scaled distance, inspect the slope and scatter, and test whether the drop energy explains the observed attenuation before relying on the relationship for planning.
Measure PPV on a defensible monitoring grid

PPV is the maximum velocity of a particle oscillating about equilibrium and is the common parameter for construction vibration monitoring [S2]. A three-component velocity sensor is needed to capture the resultant peak across vertical and two horizontal components. Fix the sensor rigidly to a stable foundation or competent ground surface, document its coordinates, and keep the same orientation for every reading [S2].
A pre-construction condition survey should record existing cracks, identify probable pre-existing causes, assess structural vulnerability, define mitigation measures and measure background vibration [S2]. For dynamic compaction, install monitoring before the first test drop and include locations at the nearest sensitive structure, intermediate distance points and a background reference location.
Record enough event data to explain each result: pounder mass, drop height, calculated impact energy, impact point, sensor coordinates, three-component waveform, peak vector PPV and dominant frequency. The frequency record matters because dynamic-compaction vibration commonly falls within 5 to 40 Hz [S5], while excitation matching a soil-layer frequency can produce unusually large motion [S1].
Define acceptance limits before production
The project team must set PPV limits from the condition and sensitivity of each receptor, not from a universal site-wide number. PPV is a response indicator, not a complete damage criterion, so structural condition, duration, frequency content and the consequences for sensitive equipment must also be considered [S2]. A building with pre-existing masonry cracking may require tighter control than a new industrial slab on competent ground.
Use trial drops to test several energy levels while stopping before an unacceptable response occurs. If measured PPV at the receptor is higher than predicted, reduce drop energy or increase the effective setback under the work plan. If PPV is below the estimate, avoid removing controls solely because one low reading appears favorable, since variable ground contact and operating sequence can change the source response.
Production monitoring should use predefined reporting intervals and assess each event against the agreed limits [S2]. Maintain a trigger response linked to measured PPV, frequency, receptor condition and repeated events. This turns the prediction into a control process rather than a one-time desk calculation.
Separate compaction performance from vibration risk

PPV is not the same as the degree of densification achieved by dynamic compaction. A low vibration level does not prove adequate improvement, and a higher PPV does not establish that the target depth was compacted. Select hammer energy for the required depth and soil treatment, then use vibration monitoring to manage the external effect [S5].
For comparison, dynamic compaction and surcharge preloading address different constraints on soft ground, so the vibration assessment should be paired with a method-specific ground-improvement review rather than substituted for it. The operating sequence, number of impacts, crane setup and impact spacing should also be recorded because they affect the total vibration exposure received by nearby receptors.
Track three signals through the work: measured PPV at each critical receptor, dominant frequency, and the number of events exceeding the action threshold. A change in PPV without a change in energy can indicate altered ground conditions, a shifted impact point, different sensor coupling or another operational factor. That comparison provides the next verification node and turns the trial into an auditable basis for production.