Select R290 or R32 for 2026 Low-GWP Heat Pumps

For 2026 low-GWP heat-pump procurement, R290 has a GWP of about 0.02 under IPCC AR6 accounting and a literature value of 3.3, delivers 70°C flow temperatures, and is an A3 flammable gas, while R32 has a GWP of 675 [S4][S6].

The practical choice is R290 for factory-sealed monoblocks, outdoor split arrangements and higher-temperature heating duty; R32 fits compact or indoor-rated A2L equipment where R290 charge limits, installation clearances and A3 training requirements would control the design [S3][S4].

R290 and R32 are compared across regulation, performance, safety, and economics.

R290 is refrigerant-grade propane, a natural refrigerant with an IPCC AR6 GWP of about 0.02, while published technical literature also reports GWP of 3.3 and commercial guidance lists GWP 3 [S4][S5][S6]. R32, or difluoromethane, has GWP 675 and an A2L safety class [S2][S4]. R410A remains materially higher at GWP 2,088 [S4].

R290 is classified as A3, meaning it is the more flammable of the two choices. R32 is A2L, a lower but non-zero flammability classification. Design decisions therefore cannot be based on GWP alone: R290 requires control of charge quantity, ignition sources, openings, ventilation and technician competence, while R32 still requires A2L-compatible equipment and service controls [S3][S4].

Compare performance, temperature and compliance on four criteria

R290 is the stronger option for high-temperature heat-pump service and for avoiding HFC quota exposure. It delivers 70°C flow temperatures and is the default choice for new monoblock heat pumps [S4].

R32 is the stronger option when equipment space, maximum charge and A3 siting constraints dominate. R32 has a GWP of 675 and is used in new HVAC equipment [S2][S3]. R290 has no HFC quota exposure and can meet a GWP 150 limit that R32 cannot meet [S4].

For equipment planners, the comparison is straightforward. R290 offers lower GWP, higher delivery temperature and no HFC quota exposure, but adds A3 controls. R32 offers A2L risk, GWP 675 and lower typical flow capability, but remains HFC-regulated. Neither refrigerant is a drop-in replacement for an existing R410A circuit.

Match R290 to outdoor and high-flow architectures

Factory-sealed outdoor monoblock architecture is the clearest R290 application because the refrigerant circuit remains outside occupied space. As an A3 flammable gas, R290 requires charge limits and trained installers [S4]. This architecture supports 70°C flow temperatures [S4].

Supply planning must include refrigerant-grade propane cylinders, recovery equipment suitable for flammable gases, leak-control procedures and trained personnel. Propane is outside the EU HFC phase-down, which separates its supply economics from R32 and R410A, but its flammability means storage and transport controls remain engineering requirements rather than optional service practices [S4][S5].

R290 is less suitable where a large charge must be located near occupied space, where the air path cannot meet A3 separation rules, or where service personnel have not completed natural-refrigerant training. It should also be avoided where the equipment supplier cannot document the applicable charge limit, installation geometry and ignition-source controls.

Use R32 where compact A2L systems have the advantage

R32 has a GWP of 675 [S2]. Its A2L classification requires less restrictive handling than R290 in suitable applications, but it is still flammable and cannot be treated as an A1 refrigerant [S2][S3].

Typical R32 heat-pump flow temperatures are 55–65°C, lower than the 70–75°C range cited for R290 monoblocks [S4]. This matters where the load includes older radiators, a domestic hot-water cylinder above 60°C or a heat-pump-only flow-temperature requirement. In those applications, R290 or a separate temperature-boost arrangement may be more suitable.

R32 remains exposed to the HFC quota system, while R290 sits outside it [S4]. For buyers, that distinction changes long-term supply risk. R32 has an established A2L equipment path, but procurement must still account for quota-adjusted pricing and the planned reduction in permitted fluorinated-gas supply.

Regulation is tightening the delivery window

Regulation (EU) 2024/573 sets a GWP limit of 150 for new monoblock heat pumps up to 50 kW and air-to-water split heat pumps up to 12 kW placed on the EU market from 1 January 2027 [S4]. That threshold excludes R32 at GWP 675 and R410A at GWP 2,088, while R290 at approximately 0.02 to 3 clears it [S4].

Published guidance sets allowable HFC supply at 31% of the 2015 baseline for the current period and 24% in 2027 [S5]. A separate supply assessment cites 42.9 Mt CO2e for 2025–2026, approximately 21.7 Mt for 2027–2029 and a full phase-out by 2050, although these figures use a different quota baseline from the 31%, 24% and 5% schedule [S4][S5].

An R290 supplier that cannot provide training, recovery and documentation should be treated as an incomplete supply offer, not simply a competitive quote.

Build procurement around service capability and refrigerant logistics

Specify the refrigerant grade, nominal charge, recovery method, shipping documentation, installer qualification and replacement-cylinder availability as one package. A low factory price on an R290 monoblock has limited value if local technicians cannot legally or practically service it. The same discipline applies to R32, whose A2L classification also affects tools, procedures and facility safety controls [S2][S4].

For an installer planning a new R290 monoblock, verify the unit charge against the manufacturer’s installation instructions, confirm outdoor siting clearances and confirm that service personnel hold the applicable natural-refrigerant qualification. For a new R32 system, verify the listed safety classification and use equipment, components and service processes approved for that refrigerant.

Track two procurement signals through 2026: the quoted delivered price and lead time of refrigerant-grade R290 versus HFC refrigerants, and the range of OEM portfolios presented as GWP 150 designs for the 1 January 2027 EU threshold. These indicators will distinguish stated regulatory readiness from distributors carrying legacy stock under an old product name.

Frequently asked questions

Which refrigerant meets the EU GWP 150 limit for new monoblock heat pumps up to 50 kW placed on the market from 1 January 2027?

R290 meets the GWP 150 limit, with reported values of approximately 0.02 to 3.3 depending on the accounting method. R32 has GWP 675 and R410A has GWP 2,088, so neither of those alternatives qualifies under the cited threshold.

What flow temperature should a heat-pump buyer specify for an R290 monoblock versus an R32 system?

Specify 70°C flow capability for an R290 monoblock [S4].

What training and service capability should be required from an R290 heat-pump supplier?

Require natural-refrigerant training, recovery equipment suitable for flammable gases, refrigerant-grade propane supply, leak-control procedures and documented installer qualifications.

Can R32 replace R410A in an existing heat-pump circuit without modification?

No. Neither R290 nor R32 is a drop-in replacement for an existing R410A circuit. R32 is classified as A2L and R290 as A3, so equipment, charge limits, siting, service controls and installation arrangements must be assessed rather than treated as an automatic retrofit.

6 sources
  1. Choosing a New System? | California Air Resources Board - CA.gov
  2. Low-GWP Refrigerants Guide 2026: R-32 vs R-454B vs R-290 Comparison ... (Mar 28, 2026)
  3. Differences between R290 and R32 Heat Pumps
  4. R290 Propane Heat Pumps: The 2027 EU Shift (Sep 14, 2026)
  5. EU F-Gas Regulation 2026: R-32, R-454B & R-410A Guide
  6. Benefits and challenges in deployment of low global warming ...

Need to source matching manufacturers or get a quote?

SpecForge connects industrial buyers with verified manufacturers. Submit your requirement and we will route it to matched suppliers.

Submit RFQ now →
Ask SpecForge AI