Hydraulic-unit selection for a gravity die casting machine starts by sizing the required actuator force, working pressure and flow, then checking that the power unit can sustain those values through the die-changing and auxiliary cycles.
The hydraulic unit supplies the controlled motion used in die changing and related machine functions, while a gravity machine uses hydraulic clamping and dosing systems on some configurations; machine tonnage alone does not determine the required electrical rating [S1][S3][S4].
Separate machine pressure from injection pressure
High-pressure die casting commonly injects molten metal at approximately 7–350 MPa, but that value describes the metal-injection process and must not be treated as the hydraulic-unit working pressure of a gravity die casting machine [S2]. In a gravity machine, molten metal generally enters the cavity under gravity rather than through a high-pressure injection plunger, so hydraulic demand depends mainly on clamping, die handling, dosing, and auxiliary functions.
A hydraulic power unit is therefore selected against the pressure and flow required at each actuator, not against the cavity pressure stated for a high-pressure die-casting process. A power unit with adequate flow can still be unsuitable if its relief setting, pressure rating, thermal capacity, or drive duty does not cover the load.
Calculate actuator force before choosing motor power
Hydraulic force follows the basic relationship F = P × A, where P is working pressure and A is effective piston area. The required force must include the load, acceleration, friction losses, and a suitable design margin; motor power then follows from the pressure and total flow demand rather than from force alone [S1].
For example, a cylinder with an effective area of 0.01 m² requires 100 kN at 10 MPa before losses or margin are added. At that pressure, delivering 60 L/min requires 10.0 kW of hydraulic power before system-efficiency allowance, calculated as pQ divided by 600 for pressure in MPa and flow in L/min. A motor with ample nameplate power can still fail if the pump cannot deliver the specified flow at the required pressure.
Hydraulic valve performance directly determines die-casting machine speed, clamping force, and injection stability [S3].
Match pressure, flow and duty as one load profile

A valid rating requires three simultaneous checks: continuous pressure at the highest static load, peak flow during the fastest actuator movement, and thermal performance over the complete duty cycle. A motor-pump pair selected only for maximum pressure may have excess torque but insufficient flow, while a unit selected only for peak flow may overheat because pressure losses remain high during the cycle [S1][S2].
The comparison matters because pressure rating answers whether the circuit can hold a load, flow rating answers whether it can move an actuator at the required speed, and thermal rating answers whether it can repeat that work without overheating. All three must pass. Hydraulic calculations should also address laminar versus turbulent flow, flow resistance and energy losses [S1].
Use machine architecture to define auxiliary loads
General-purpose gravity die casting equipment can include an upper hydraulic unit associated with the die-changing device, a hydraulic unit for multiple casting operations, and an inverter-based energy-saving arrangement [S4]. These functions define distinct actuator duties, so each should be mapped to its own pressure, flow and operating duration rather than combined into one unrestricted full-load figure.
For a gravity die casting machine, the hydraulic package may be smaller than the package used for a high-pressure machine because it does not need to drive a high-pressure molten-metal injection plunger. The absence of injection hydraulics does not remove the need for controlled clamping and handling, and it does not establish a universal kW rating because clamp size, parting-line force, die weight, acceleration, valve losses and cycle frequency can differ substantially.
Large hydraulic cylinders may require high flow during approach and retraction, while small pilot or ejector cylinders may require less flow but sharper pressure control. The hydraulic pump, motor, reservoir, heat exchanger, filtration and relief arrangement must be reviewed as one subsystem because changes in one component alter pressure loss and thermal duty across the circuit [S1].
Apply constraints for contamination, temperature and controls

Hydraulic systems serving die-casting equipment require active contamination control because particle ingress, cavitation and erosion can affect pumps, valves and seals [S1]. Filtration requirements depend on the components and contamination sources involved, while reservoir and heat-exchanger selection affect fluid temperature, aeration and thermal capacity [S1].
Rated working pressure alone does not protect the installation if the pipe, hose, fitting, filter, valve or accumulator has a lower allowable rating.
A modern machine must also reconcile hydraulic behavior with electro-mechanical and PLC-controlled processes [S1]. Pressure override, motion timing, accumulator behavior and emergency holding functions should be verified under the machine control logic. These controls affect repeatability more directly than a nominal motor horsepower figure.
Apply the limits of the available rating evidence
The cited material defines the role of hydraulics and provides hydraulic calculation principles, but it does not establish a universal power or pressure rating for every gravity die casting machine [S1][S2][S3][S4]. A supplier rating should therefore state at least the motor kW, pump displacement and maximum pressure, continuous and peak flow, reservoir capacity, fluid type, temperature limits, cooling requirement, duty cycle and control voltage.
Do not accept a quotation that lists only “hydraulic unit power.” Require the operating pressure at each major actuator, maximum flow, simultaneous-load sequence, cycle duration, ambient conditions and required redundancy. For a supplier review, the gravity die casting machine specification should distinguish the machine’s casting clamp size from the hydraulic power package and state whether the quoted figure is motor input, hydraulic output, continuous rating or peak rating.
For pressure-transient decisions, the related guide to die casting accumulator pressure and fast-shot speed provides a separate engineering check for fast injection, but accumulator calculations should not be transferred directly to gravity-machine auxiliary circuits.
The traceable acceptance point is a matched load profile: every actuator must have adequate force at the selected pressure, every timed movement must have enough flow, and the complete cycle must remain within the motor, pump, thermal and component limits.