Gear-pump selection must reconcile fluid chemistry, viscosity, flow rate, pressure, power, efficiency and operating temperature before the wetted-material specification is approved [S1].
External and internal gear designs suit different duties: internal gears generally provide better suction capability and are commonly selected for higher-viscosity liquids [S4].
Define the chemical service before selecting the pump
The service definition should identify the fluid, concentration, temperature, viscosity range, required flow, discharge pressure, contaminants and whether the duty is transfer or metering. Chemical processing commonly includes acids, alkalis, oxidizers, solvents, chlorinated hydrocarbons and petroleum-derived liquids; each family attacks a different material combination [S2][S3].
Material selection must cover every wetted component, not only the housing. Available gear-pump constructions include cast iron, cast steel, stainless steel and high-nickel alloys [S6]. Standard ductile iron construction is adequate for many industrial fluids, while stainless steel provides superior corrosion resistance and gear material selection is equally critical [S3].
For a detailed comparison of positive-displacement and dynamic pumping duties, compare the candidate with centrifugal pump selection criteria. Gear pumps are positive-displacement machines, so their delivered flow is tied to speed and displacement rather than primarily to discharge head.
Match internal and external gear designs to the duty
Internal gear pumps generally provide better suction performance than external gear designs and are suited to high-viscosity fluids [S4]. External gear pumps are widely used for liquid transfer where positive displacement and serviceability are priorities, while gear metering pumps add controlled displacement for chemical dosing duties [S5].
Gear pumps are most applicable to low-to-medium viscosity liquids and are used in high-flow petroleum and chemical applications [S7].
Specify compatible housing, gear and seal materials

Stainless steel resists many organic acids, mild mineral acids and alkaline solutions, but chlorinated solvents can attack elastomers that appear suitable in other services [S3]. Material compatibility must therefore be checked by component, including housing, shaft, gears, seals and any selected PTFE component [S2][S3].
Benzene, toluene, xylene, and other aromatic compounds can swell and degrade nitrile rubber [S3].
Chlorine, hydrogen peroxide, permanganates, and other oxidizers attack ductile iron rapidly [S3].
The pump order should separate housing corrosion resistance from gear and seal compatibility. That configuration does not, by itself, qualify nitrile gears, Viton seals or PTFE parts for every chemical.
Set flow, pressure and power from real operating limits
The minimum acceptable flow, maximum and minimum viscosity, maximum discharge pressure, suction pressure, speed, temperature and driver power belong in one duty sheet. These are not interchangeable ratings: a positive-displacement pump must be matched to the system resistance and operating flow, while the driver must cover the calculated power demand at the specified fluid viscosity [S1].
For chemical transfer, near-constant flow and a fixed volume moved per revolution are defining operating benefits of positive-displacement gear action [S3]. For chemical metering, low-pulsation gear metering pumps are designed for precise transfer of aggressive media [S5]. Metering selection should separately establish required dose rate, turndown, accuracy and allowable pulsation rather than inferring them from transfer-pump capacity.
Protect suction, discharge and the pump internals

Suction conditions must be evaluated with the pump geometry because internal gear pumps generally have better suction capability than external gear designs [S4]. Internal gear pumps typically have better suction capabilities than external gear designs and are suited to high-viscosity fluids [S4].
Positive-displacement gear pumps provide near-constant flow regardless of viscosity or pressure, and their mechanical gear action moves a set volume of fluid forward with each revolution [S3]. Low-pulsation gear metering pumps are specifically offered where chemical dosing requires a smoother delivery profile [S5].
Field serviceability is also a chemical-process design criterion. Repair kits and on-site rebuild capability can reduce outage duration, but the selected gear and seal materials must be verified against the exact fluid and temperature before accepting a maintenance strategy [S3].
Apply the correct chemistry-specific screening rules
For aromatic solvents, specify an elastomer explicitly qualified for the named solvent, such as Viton where supported, instead of accepting a generic nitrile seal [S3]. For oxidizing service, exclude vulnerable ferrous components or require test evidence for the exact oxidizer, concentration and temperature [S3].
For alkaline service, consider stainless steel or ductile iron only after checking the specific concentration and temperature, and remove aluminum or copper-alloy components where attack is credible [S3]. For chlorinated hydrocarbons, require compatibility testing because both nitrile and some Viton formulations may deteriorate [S3].
PTFE is identified for handling aggressive chemicals, but it should be treated as one material option rather than a complete pump specification [S2]. A chemical datasheet, concentration, temperature and compatibility test are more defensible than a broad label such as “chemical resistant.”
Build a shortlist that procurement can price and approve

Shortlist internal gears when suction capability and high viscosity dominate; use external gears when general chemical transfer and straightforward positive-displacement duty dominate; use a gear metering pump when the output is a controlled dose and low pulsation is required [S4][S5].
Do not choose the mainstream external gear pump when the fluid is outside its viscosity range, the application requires low-pulsation dosing, or the wetted parts cannot be qualified for the exact chemical [S5][S7]. Do not approve a stainless steel pump merely because the housing is stainless, since elastomers and gears remain separate compatibility decisions [S2][S3].
For the final data sheet, require at least 3 candidate chemical concentrations, the minimum and maximum viscosity, operating temperature range, required flow, discharge pressure, suction conditions, motor power, elastomer grade, shaft material, gear material and availability of a repair kit. The shortlist is acceptable when the worst-case duty is covered by a material compatibility basis and the selected geometry matches the viscosity and metering requirement.