Three-phase asynchronous motors are classified mainly as squirrel-cage or wound-rotor machines, with 2, 4, 6 and 8-pole configurations selected by speed, power and frame size [S2][S4].
The two rotor constructions cover different duties: squirrel-cage drives dominate pumps, fans and compressors, while slip-ring motors serve elevators, hoists and cranes where starting torque or speed control is more important [S4][S5].
Rotor construction defines the main motor classes
A three-phase asynchronous motor produces torque through electromagnetic induction: the rotating stator field induces rotor current, and interaction between the two fields creates mechanical output [S3][S5].
In a squirrel-cage rotor, conductive bars are joined by end rings and mounted in laminated steel, with no electrical connection to the rotor required [S3][S4]. This arrangement supports self-starting operation, economical construction and low maintenance, explaining its wide industrial use [S3][S5].
A wound-rotor, or slip-ring, motor uses rotor windings connected through slip rings to external resistors [S5]. The added circuit permits higher starting torque and speed adjustment, but it introduces maintenance requirements and greater mechanical complexity [S4][S5].
Speed follows poles, frequency and slip
The synchronous speed of an induction motor is calculated as S = 120f/P, where f is supply frequency in hertz and P is the number of stator poles [S4]. A 60 Hz, 4-pole machine therefore has a synchronous speed of 1,800 rpm, while an actual running speed remains below that value because slip is required to generate torque [S4][S5].
At 50 Hz, common 2, 4, 6 and 8-pole arrangements correspond to synchronous speeds of 3,000, 1,500, 1,000 and 750 rpm before slip [S2][S4]. Pole count is therefore a primary selection variable when a driven load requires a particular nominal speed.
Three-phase squirrel-cage induction motors are widely used as industrial drives because they are self-starting, reliable, and economical [S3].
Selection criteria separate practical applications

The principal comparison is squirrel-cage versus wound-rotor: cage construction wins on maintenance, cost and efficiency; wound-rotor construction wins on starting torque and rotor-side speed control [S4][S5].
Three-phase induction motors fit loads needing continuous operation at steady speed, whereas wound-rotor machines are justified when the mechanical load requires high breakaway torque or controlled acceleration [S4][S5]. A stepper motor is more appropriate for commanded positioning, while a servo motor is selected when closed-loop torque or precise dynamic response is required.
Enclosure and cooling define environmental fitness
Available enclosure protection includes IP55, IP56, IP65 and IP66, covering combinations of dust ingress and water protection requirements [S2].
In TEFC motors, interior heat losses are dissipated indirectly through enclosure fins, mostly by forced air convection [S3]. Cooling arrangement therefore affects mechanical layout, allowable duty and suitability for high-ambient installations.
The ABB technical paper identifies food, chemical, metallurgical, paper, water-treatment, extraction, lifting, conveyor, ventilation and air-conditioning applications within the broad industrial scope of asynchronous motors [S1].
Thermal class and starting method constrain the duty

These class temperatures relate to insulation thermal capability and must be matched to the specified ambient conditions, duty cycle and allowable temperature rise.
Squirrel-cage motors can start direct-on-line or through reduced-voltage methods including star/delta, autotransformer, stator resistor or reactor, and soft starting [S1]. Reduced-voltage starting limits the current and mechanical stress applied during acceleration, while direct-on-line starting remains the simplest arrangement when the supply and driven system can absorb the starting demand.
Star/delta starting, for example, reduces the line voltage applied at starting, but the transition method and connection must be coordinated with the load and protection arrangement [S1]. Wound-rotor starting instead uses resistance in the rotor circuit to control torque during acceleration [S4][S5].
Protection and operating limits complete the specification
Motor protection must account for starting current, thermal overload, phase loss and the coordination between the motor and its switching and protective devices [S1]. ABB's 48-page technical paper separates normal starting from heavy starting and discusses coordination type 1 and type 2 for motor-starting equipment [S1].
Enclosure rating, thermal class, pole count, frame size, duty and starting method should therefore be checked together rather than treated as independent catalogue fields.
For variable-speed machines, power loss and thermal behaviour depend on operating point, so VFD compatibility must be confirmed rather than inferred from the three-phase rating alone [S3]. Further selection guidance is available in Select AC Motors by Operating Principle and Load.
The next procurement step is to document rotor type, rated kW, poles, voltage, frequency, IP rating, thermal class, frame size, duty and starting method; the selected combination should then be verified against starting current, load torque, thermal rise and protection coordination [S1][S2].