Linear motors produce linear force along their length rather than rotary torque, and are used by the millions in high-accuracy CNC machining and industrial robots.
Selection depends on stroke, payload, acceleration, positioning accuracy, feedback method, and drive electronics; no single construction satisfies every machine-tool, transport, semiconductor, or robotics duty [S3][S4].
Primary and secondary define the motor structure
A linear motor can be understood as a rotary motor opened along a radial plane and unrolled into a primary and secondary, producing linear force instead of torque [S4]. The primary normally contains coils in a steel, epoxy, or aluminum structure, while the secondary depends on motor type and may contain permanent magnets, windings, or conductive material [S5].
A non-contact air gap of approximately 0.6 mm is cited for a typical linear-motor arrangement [S5]. The active section is finite, with ends that differ from the continuous structure of a conventional rotary motor [S2]. In a Lorentz-type actuator, force is proportional to current and magnetic field, expressed as F = I(L × B) [S2].
Construction is also classified geometrically. Flat motors, tubular motors, and U-channel motors are common industrial forms, while a U-channel synchronous example can use two coil sets energized in quadrature, separated by a 90° phase difference [S2][S3].
Synchronous linear motors cover precision motion
Synchronous linear motors place a winding on one side of the air gap and an array of alternating-pole magnets on the other, with permanent magnets or electromagnets serving as the magnetic member [S2].
Brushless linear motors belong to the synchronous family and commonly serve standard linear stages and custom high-performance positioning systems [S2]. Ironless and iron-core versions are available, both operating without physical contact and using standard three-phase brushless servo amplifiers [S4]. Some linear-motor versions can operate continuously, provide 5 g or higher acceleration, and offer a low settling time.
Permanent-magnet synchronous motors are widely used for high-performance applications, while brush-type synchronous versions operate from direct current and generally represent the lower-cost version [S5]. Three-phase brushless drives provide greater flexibility than the single-phase brushed arrangement commonly associated with older industrial installations [S2].
Induction motors prioritize long travel and heavy payloads

Linear induction motors generate force through currents induced in a conductive secondary, with the induced magnetic flux interacting with the primary current [S5]. The secondary can use short-circuit rods and is inexpensive for long-travel systems, but the complete motor is larger than an equivalent permanent-magnet design [S5].
A flat three-phase linear induction motor can operate from line voltage with adjustable frequency or require a vector drive for controlled speed [S4]. Some linear-motor versions can operate continuously, provide 5 g or higher acceleration, and offer a low settling time. These characteristics suit long strokes, heavy payloads, and applications where a large secondary structure is acceptable [S4].
Precision induction systems demand more complicated control algorithms, so they are strongest in low-duty-cycle applications where long travel matters and heat is manageable [S5]. A high-acceleration linear induction configuration typically combines an active three-phase winding with a passive conductor plate across the air gap [S2].
Tubular motors support compact force packages
Tubular linear motors use a cylindrical geometry, while homopolar designs are characterized by a single magnetic route and direct-current operation [S1]. A tubular AC linear induction motor, also called a polynoid, can run from single-phase or three-phase line voltage and offers acceleration greater than 1 g [S4].
Polynoid motors fit short-stroke, low-duty-cycle duties, including applications where pneumatic air is unavailable [S4]. Their cylindrical package differs fundamentally from the flat and U-channel layouts commonly encountered in industrial automation [S3].
Geometry alone does not determine the motor family. A tubular machine may use induction or another electromagnetic principle, so procurement documents should specify both the mechanical configuration and the electrical operating method rather than using “tubular” as a complete classification [S1][S4].
Stepper and voice-coil motors serve different control duties

Linear stepper motors are discrete positioning devices commonly operated open loop, without external position feedback, although closed-loop versions are available [S4][S5]. Linear motors are used for open-loop positioning applications, servo applications requiring high forces, and applications needing long linear movement.
Multiple forcers can share one platen, and open-loop operation removes the need for servo tuning [S4].
Voice-coil motors normally use a stationary coil and moving magnet, with travel commonly below 25 mm in one cited classification [S5]. Some linear-motor versions offer smooth motion to within a fraction of a percent of their nominal velocity, while others can operate continuously, provide 5 g or higher acceleration, and offer a low settling time.
Brushed, homopolar, and piezoelectric alternatives
Brushed direct-current linear motors served industrial automation before brushless systems and normally operate as single-phase machines [S2]. One published brush-motor range covers 25 mm/s to 2.5 m/s, with precise position, velocity, and acceleration control achieved by coupling the motor to a linear encoder [S4].
Homopolar linear motors use direct current and a single magnetic route [S1]. Direct-current homopolar designs are also identified as one route for high-acceleration motors, while low-acceleration, high-speed, high-power machines are generally synchronous [S2].
Piezoelectric linear motors form a separate classification from electromagnetic rotary-derived machines [S2]. Their inclusion means that “linear motor” can also describe a piezoelectric positioning actuator rather than only an unrolled rotary motor, so motion design should state whether the required force source is electromagnetic, reluctance-based, or piezoelectric.
Selection criteria expose the practical trade-offs

On four criteria, brushless synchronous motors offer the strongest combination for high acceleration, compact mechanical packaging, and precise servo positioning; induction motors lead where long travel and heavy-payload economics dominate; stepper motors favor open-loop affordability; voice-coil motors favor short-stroke, high-dynamic-response work [S4][S5].
For a comparison of linear motor types, brushless systems are specified by peak acceleration and encoder-dependent positioning, induction systems by travel length and thermal duty, stepper systems by step resolution and holding-force behavior, and voice-coil systems by stroke and moving mass. Published stiffness can reach 0.9 million N/mm in some linear-motor designs, while velocity can span 1 μm/s to more than 5 m/s depending on architecture [S5].
The linear motor category is not a substitute for a complete datasheet. A purchase specification should define payload, stroke, peak and continuous force, velocity, acceleration, required accuracy, cooling, feedback device, power supply, amplifier type, and environmental limits. A basic motor protector may be relevant when a drive system includes suitable overload protection, but it does not replace motor sizing.
Linear motors are appropriate for CNC machines, robots, inspection systems, pick-and-place equipment, semiconductor machinery, photonics alignment, and long-travel transport. They are less suitable when the lowest initial cost outweighs the benefits of direct drive, when open-loop motion cannot meet the accuracy requirement, or when a compact actuator cannot provide the required stroke [S2][S4][S5].
Application data determines the correct class
Selection should start with the machine duty and move backward to the motor family. A precision stage with nanometer-scale positioning requirements points toward a brushless synchronous motor with suitable feedback and drives, while a long transport system may favor induction or a low-acceleration synchronous design [S2][S3].
High-acceleration designs are normally short and purpose-built to accelerate a mass to a high speed, whereas low-acceleration designs suit ground transportation such as maglev trains [S2]. For industrial automation, the stepper motor types compared for accurate selection framework can help distinguish open-loop and feedback-assisted positioning approaches before the mechanical envelope is fixed.
Two trackable procurement signals should remain on the specification: the rated continuous and peak operating point, including duty cycle, and the feedback architecture that will support the intended accuracy. Published examples show why both matter, with induction systems defined by thermal and control constraints while brushless systems are evaluated by acceleration, speed, and encoder performance [S4][S5].