Falling-Film Evaporator

A falling-film evaporator is a vertical shell-and-tube heat exchanger in which the liquid to be concentrated is distributed as a thin film at the top of heated tubes and flows down the inner walls under gravity while evaporation takes place at the film surface, with vapor and concentrate separating at the bottom. Because the film is thin and gravity-driven, evaporation occurs at temperature differences of 3 to 8 deg C and residence times of seconds, which preserves heat-sensitive products: milk and whey before they taste cooked, fruit juice with its volatiles intact, pharmaceutical extracts, and heat-sensitive chemicals. Single effects serve small duties; trains of three to seven effects, or single-effect machines with mechanical vapor recompression, MVR, dominate industrial water removal at steam economies from 1:1 up to 1:30.

Procurement engineers meet this equipment wherever water must leave a product gently and in quantity: dairy powder plants concentrating milk from 12 to 50 percent solids, juice and coffee concentrate lines, ethanol stillage and corn steep water, black liquor in pulp mills, amino acid and fermentation broths, and industrial wastewater volume reduction. The decision this page settles is narrow and practical: how tube length, wetting rate, and distribution quality decide whether the film stays intact or burns, how many effects or which recompression option pays at the site's energy prices, what vacuum system and condenser complete the machine, and how the RFQ line set converts a duty list into a train that starts up clean and stays clean between CIP cycles.

Cutaway diagram of a centrifugal steam and water separator vessel with wet steam entering curved vanes, separated water draining off the bottom and dry steam exiting the top, the vertical vessel-with-internals phase separation architecture that falling film evaporator calandrias and vapor separators share

Image: Scanned by Didier Duforest, CC0, via Wikimedia Commons

This page treats the falling-film evaporator as a purchasing object: how the calandria, distributor, and separator divide the work, why wetting rate discipline decides the difference between a decade of clean tubes and a fouling campaign, how effect count and MVR or TVR economics set the energy bill, and how vacuum, condenser, CIP, and instrumentation lines complete a train an operator can actually run. It is written for engineers who sign evaporation duty specifications, not for readers who want a brochure summary.

Chapter 1 / 06

What a Falling-Film Evaporator Is and What Is Being Decided

The machine has three organs. The calandria is the vertical tube bundle, tubes typically 6 to 15 m long and 25 to 50 mm in diameter, with steam or vapor condensing on the shell side and the process film falling inside the tubes; it is a shell and tube heat exchanger standing on end with the process on the tube side by design. The distributor is the top plate work, holes, spray nozzles, or weir channels, that spreads feed liquor perfectly evenly into every tube, because a tube that runs dry fouls and a tube that floods loses its heat transfer. The separator, a vessel at the bottom or beside the calandria, disengages vapor from concentrate, usually with a demister or vane pack of the mist eliminator family to hold entrainment out of the vapor path. Everything else in the plant, preheaters, pumps, vacuum system, condenser, is arranged in service of those three.

What is being decided in this purchase is water removal with product quality attached. The vendor promises an evaporation capacity in kilograms of water per hour, a final concentration, and, implicitly, a product outcome: no cooked flavors, no color pick-up, no thermal degradation beyond the specification. The buyer's protection is the process design disclosure: film wetting rates per tube at minimum and maximum feed, residence time, top and bottom temperatures, effect-by-effect heat loads, and the energy economy basis. Two evaporators with identical capacity tags can differ by a whole season of CIP downtime, and the difference lives in numbers the RFQ can demand: tube count and length against turndown feed, distribution type against fouling propensity, and the energy option chosen against the site's steam and power prices.

The competitive frame within evaporation technology is short to state. Forced circulation evaporators pump liquor through the tubes at high velocity and evaporate in a separate flash zone; they win on fouling and crystallizing services, scaling, salts, and viscous slurries, at the price of higher temperature difference and residence time. Rising film evaporators climb the tubes by vapor shear, the older architecture, tolerant of distribution imperfection but needing larger temperature differences and longer residence. The falling-film machine wins the heat-sensitive, low-viscosity-to-moderate band, dairy, juice, clean chemicals, wastewater, with the lowest temperature difference and shortest residence of the thermal family. Wiped-film and thin-film evaporators, mechanical agitators spreading the film in short wide bundles, own high viscosity and fouling extremes at small scale, and they are neighbors in the selection chapter, not versions of this machine.

The energy architecture is the purchase's second decision, taken in the same order of magnitude as the calandria itself. A single-effect machine consumes roughly one kilogram of steam per kilogram of water evaporated. Each added effect in a train reuses the vapor as heating medium for the next, so a five-effect train approaches a steam economy of 4 to 5 kilograms evaporated per kilogram of steam, paying for its extra bodies in energy saved. Thermal vapor recompression, TVR, uses a steam ejector, the same thermodynamics as the steam ejector leaf, to boost part of the vapor to reusable pressure and buys the equivalent of an extra effect at low capital. Mechanical vapor recompression, MVR, compresses the whole vapor stream with a fan or compressor to condense it back in the same calandria, running at an effective economy of 10 to 30 equivalents on electricity, the standard choice where power is available and steam is expensive, and the architecture behind most modern dairy and juice concentrators.

The train's cold end completes the machine. Evaporation runs under vacuum, 40 to 90 deg C boiling by product sensitivity, so the vapor must be condensed and the non-condensables removed: surface condensers of the shell and tube or plate heat exchanger family, or direct contact spray condensers, reject the heat to cooling water, and a vacuum system, a steam ejector train or a liquid-ring vacuum pump, holds the vacuum against air in-leakage and dissolved gases. The condensate polish, product value in the condensate, BOD in the wastewater, is often a purchase line too, a condensate return pump sends clean condensate back to the boiler house on steam heated trains, and the concentrate handling and product storage close the battery limits. An evaporator quoted as a calandria with no vacuum, condenser, and energy basis is a vessel, not a process.

Chapter 2 / 06

How the Film Does the Separation Work

The film is the machine. A falling film tube in healthy operation carries 0.1 to 0.5 mm of liquid down its wall in laminar-to-wavy flow; heat crosses the condensing steam film on the outside, the tube wall, and the process film, and evaporation happens at the film surface, not at the wall, so the liquid itself never approaches wall temperature. That is the entire quality argument for the architecture: product temperature stays at the local boiling point, typically 45 to 80 deg C under vacuum, no matter how hot the heating steam, because the film carries the heat away as latent vapor rather than letting it accumulate in the liquid. Overall heat transfer coefficients run 1,000 to 2,500 W per square meter kelvin in clean dairy service, among the best in evaporation, precisely because both sides are films.

Wetting rate is the discipline that keeps the physics alive. Each tube must receive enough liquor per unit of perimeter, at every operating point, to keep its whole inner surface wetted; typical design floors run 0.25 to 0.5 liters per second per meter of perimeter for water-like feeds, higher for viscous or foaming products, and the number is checked at the minimum feed case, because a train that turndowns to half feed divides its wetting with it. A tube that runs partially dry develops local fouling within hours, the fouling insulates, the dry patch grows, and the calandria heads toward the blocked-tube cleaning campaign that defines badly bought evaporators. Wetting discipline is why tube count is not a free variable, why long tubes are preferred, 10 to 15 m over 6, for the same area, and why the distributor is engineered rather than drilled hopefully.

Distribution is the top-of-tube art. Feed enters a distribution plenum above the tubesheet and must divide to plus or minus a few percent across hundreds of tubes: designs use perforated plates in cascade, spray nozzles, or weir-and-overflow tubes, and each has a fouling and turndown character of its own. Maldistribution is self-punishing, the wet tube evaporates and concentrates while its dry neighbor fouls, and the symptom is the same from every cause: rising delta-T across the calandria and falling evaporation between CIPs. The purchase line is the vendor's distribution design statement with its turndown range, and the acceptance test includes a turndown demonstration, not just a full-rate run.

The temperature difference is small by design and by consequence. Falling films evaporate at 3 to 8 deg C driving force, which is the quality gift, and the constraint that shapes the train: small delta-T per effect means many effects with small total temperature lift, so effect count is set by the available temperature span between heating steam and cooling water, and every degree lost to fouling, boiling point rise, or pressure drop is paid in capacity. Products with high boiling point rise, concentrated sugars and salts, consume the span before the calandria ever sees it, and viscous products thicken their films until the coefficient sags. The heat balance per effect, load, delta-T, area, is the design disclosure the RFQ should demand effect by effect, because that table is where two bidders differ and where a train's weaknesses are visible on paper.

Residence time completes the quality story. A falling film spends one to three minutes in the hot zone from distributor to separator, compared with tens of minutes in forced and natural circulation bodies, and the product quality outcomes, no Maillard browning in milk at 55 to 65 deg C, aroma retention in juice, activity retention in pharmaceutical extracts, follow directly. The thermal design and the quality specification are therefore the same document: the RFQ states maximum product temperature and maximum residence, and the vendor's effect count, operating vacuum, and film design answer it. On aroma-sensitive duty, a vapor recompression design that boils at 55 deg C in a single gentle pass is a different product machine from a five-effect 90 deg C train of the same capacity, whatever the capacity tag says.

Vapor handling closes the loop between effects. Vapor leaving a separator carries droplets; a demister of the mist eliminator family returns the coarse fraction, and entrainment beyond that contaminates the next effect's condensate or the MVR compressor. Vapor ducts are sized for low pressure drop because every pascal is temperature lost between effects, and the condenser and vacuum system set the train's cold end temperature, and with it the whole available span. The instrumentation that proves the physics in operation, a level transmitter on each separator and calandria sump, a pressure transmitter per effect, temperature at each top and bottom, and a flow meter on feed and concentrate, is the operating window; a train without per-effect instrumentation is run by folklore until its first crisis.

Chapter 3 / 06

Types, Construction, and Duty Boundaries

Tubular versus plate is the first construction fork. Tube-based falling-film calandrias, 10 to 15 m stainless tubes in vertical shells, own the industrial scale: they are robust, cleanable, and proven from 1,000 to 100,000 kilograms per hour of evaporation, and the whole multi-effect and MVR vocabulary is built around them. Plate falling-film machines, corrugated plate packs in frames of the plate heat exchanger family, offer short residence in a compact frame, hygienic finishes, and easy capacity changes by adding plates; they serve mid-scale dairy, pharma, and specialty duty, and recent heat-pump process projects have paired plate falling-film stages with heat pumps for low-temperature industrial concentration. The trade is area density and hygiene on the plate side against robustness and scale on the tube side, and the fouling class of the feed usually makes the call.

Effect count and energy option define the train type. Single-effect machines with MVR are the modern default for water removal below roughly 30 tonnes per hour where power is available: one calandria, one compressor, effective economies of 10 to 30, gentle single-temperature operation, and the smallest building. Multi-effect trains of three to seven bodies, steam-heated, remain the answer where cheap steam exists or power is weak, and TVR hybrid trains buy an effect's worth of economy with an ejector where steam pressure supports it. The choice is an energy price calculation the RFQ should force with stated steam and power prices and stated hours per year, because the capital split between the options is large and the wrong choice is a lifetime penalty.

Configuration details follow the product. Once-through designs pass feed down each effect in series and out at final concentration, minimum residence, standard for heat-sensitive duty. Recirculation designs hold a sump and recirculate partially concentrated liquor, evening out feed fluctuations and raising wetting security at the price of residence time, common on wastewater and robust industrial duty. Finisher effects, a small forced-circulation body after the falling-film train, handle the final push into high solids where viscosity would starve a film. Preheaters, direct or with regenerative flash, recover condensate and vapor heat into incoming feed, and thermal compression arrangements, the TVR ejector between effects, tune economy without adding bodies. Each of these is a line on the process flow diagram the vendor should be required to submit with the bid.

Materials and hygiene class follow the industry. Dairy, food, and pharmaceutical machines are 304 or 316L stainless throughout with hygienic welds, crevice-free distribution, and CIP built in from the first drawing; chemical and wastewater machines trade finish for alloy, duplex or higher where chlorides concentrate, because the last effect of a wastewater train is an aggressive brine. Black liquor and stillage duty lean on standard stainless with fouling management. The tube-to-tubesheet joints, expanded or welded, the gasket inventory, and the surface finish class, Ra by industry, are purchase lines, and the spares list, gaskets, seals, and one complete distribution rebuild kit, belongs in the same order as the machine.

Duty boundaries, stated bluntly. This is not a crystallizer: salts that drop solids in the bundle belong in forced-circulation or specific crystallizer designs, and a falling film fed supersaturated brine is a fouling campaign with a pump. It is not the high-viscosity machine: beyond a few hundred centipoise the film cannot be maintained reliably and the wiped-film or thin-film evaporator family takes over, with its mechanical rotor spreading the film. It is not a flash tank: a flash vessel drops pressure on already-hot liquid and separates the flashed vapor, no heating surface, and it appears beside this machine in trains but does not concentrate by itself. It is not a dryer: after concentration, spray and drum dryers take over, and the evaporator's job ends at pumpable concentrate. And it is not its neighbors in the condensing world, the evaporative condenser rejecting refrigeration heat; that machine condenses, this one evaporates product water. The table below consolidates the duty map.

ServiceConstruction to specifyBoundary to respect
Milk and whey concentrationTubular falling film, 3 to 5 effects or MVR, hygienic, CIP fullMaximum 65 to 70 deg C product; aroma and protein spec
Fruit juice and coffee extractOnce-through, low temperature, aroma recovery optionVolatile retention governs; vacuum depth is quality
Ethanol stillage and corn steepMulti-effect with finisher, fouling allowanceViscosity at final solids; forced finisher stage
Fermentation broth, pharma extractSingle-effect MVR or plate machine, small holdupValidation scope; cleanability documentation
Industrial wastewater volume cutRecirculation design, alloy last effect, TVR or MVRChloride concentration in final effect corrosion
Black liquor concentrationRugged multi-effect, soot and scale managementHigh solids finish; viscosity and scaling limits
Crystallizing salt solutionForced circulation crystallizer insteadFalling film fouls on suspended solids growth
Chapter 4 / 06

Key Specification Parameters

The datasheet rows below decide whether a quoted train matches the duty. Each row is a purchase defining parameter; the paragraphs after the table explain what to demand and what a weak answer looks like.

AttributeTypical range or optionsWhat it decides
Evaporation capacity1,000 to 100,000 kg/h water removedTrain size, effect count, and capital band
Feed and product concentratione.g. 12 to 50 percent solids dairy; duty stated pairViscosity profile and finisher need
Number of effects or energy option1 to 7 effects; MVR; TVR hybridSteam economy and the energy bill for the decade
Steam economy, guaranteed1:1 single; 4 to 5 five-effect; 10 to 30 MVR equivalentThe operating cost the purchase stands on
Operating temperature and vacuum40 to 90 deg C boiling; 50 to 200 mbar typicalProduct quality ceiling and vacuum plant size
Calandria geometryTubes 25 to 50 mm, 6 to 15 m; plate packs alternativeArea, wetting security, and cleanability
Wetting rate at minimum feed0.25 to 0.5 L/s per m perimeter floor by productDry-patch fouling immunity at turndown
Distribution typePerforated plate cascade, nozzles, weir tubesTurndown range and fouling behavior
Residence time1 to 3 min once-through; longer recirculationHeat sensitivity compliance
Materials and finish304, 316L, duplex by chloride; hygienic weldsCorrosion and hygiene acceptance
Vacuum systemSteam ejector train or liquid-ring vacuum pumpCold end temperature and its stability
CIP provisionBuilt-in circuits, spray coverage, cycle designAvailability between cleanings

The wetting and distribution rows are the decade rows. Demand the wetting calculation at minimum and maximum feed, per effect, because concentration rises effect by effect and the last effect's viscosity is the hardest film to hold; demand the distribution design statement with its turndown ratio; and reject any bid that treats tube count as a commercial variable cut from the thermal design. The acceptance test should include a turndown run with delta-T trended, because the dry patch that will define the machine's cleaning schedule is invisible at full rate and obvious at half.

The energy rows deserve the second interrogation because they are the largest operating cost the purchase controls. State steam and electric prices and annual hours in the RFQ and demand guaranteed steam economy at design point, with the basis, per kilogram of water evaporated, stated for each proposed architecture: effect count options and the MVR alternative priced against each other on the same energy prices. The vendor who quotes only the cheapest capital train against an unstated energy basis has not answered the question; the vendor who shows the crossed lines, capital against operating, at your prices has done the engineering you are paying for.

The temperature and vacuum rows carry the quality guarantee. Maximum product temperature, boiling range per effect, and residence time belong on the datasheet with the concentration pair, and the vacuum system sizing, air removal capacity at cold end temperature, decides whether those numbers hold on a hot summer afternoon when cooling water is at its worst. The parallel table compresses the vacuum and cold end decision; the rule under it: the vacuum plant is sized for the worst cooling water day, not the average, because the train's capacity and quality both sag with every degree the condenser loses.

Cold end contextArrangement to specifyWatch items
Cold cooling water, 15 to 25 deg CSurface condenser plus single-stage ejector or ring pumpVacuum depth headroom; condensate polish
Warm water, 28 to 35 deg C siteTwo-stage ejector or larger liquid-ring with precondenserSummer capacity derate honestly stated
Water restricted siteAir-cooled condensation or hybridApproach temperature penalty on the whole train
Product volatiles in vaporSurface condenser with fractionation or aroma side drawCondensate BOD and recovery value
High non-condensable feed loadOversized air removal with CO2 and O2 allowanceDissolved gases flashing in first effect

The instrumentation and CIP rows make the train operable. Per-effect pressure and temperature, separator levels, feed and product flow, and condensate conductivity, read by a conductivity meter or equivalent, are the minimum window; a steam economy computed online from these readings is the management instrument that keeps the guarantee honest for the decade. CIP scope, circuits, spray devices in separators and ducts, cycle chemistry, and the time budget per cleaning, is availability engineering: a train that cleans in three hours runs more campaigns per season than a train that cleans in eight, and that difference is worth more than a few square meters of area.

Chapter 5 / 06

Selection Decision Factors and RFQ Language

The decision sequence runs as a checklist, and each step eliminates a class of quotations before price comparison begins.

  1. Write the duty honestly: feed rate and composition with its fouling class, concentration pair, and the product quality limits, maximum temperature and residence, that bound the design.
  2. State energy prices and hours: steam, power, and cooling water conditions through the seasons, because effect count and MVR economics are arithmetic on those numbers.
  3. Choose the energy architecture on the crossed-line calculation: single-effect MVR versus three to five effects versus TVR hybrid, at your prices, not the vendor's defaults.
  4. Fix the temperature and vacuum basis: boiling temperature by effect at worst-season cooling water, and size the vacuum plant for that day.
  5. Audit wetting and distribution: wetting rate at minimum feed per effect, distribution design statement, turndown demonstration in the acceptance test.
  6. Fix materials by the last effect's chemistry, chloride concentration at final concentration, not by the feed water's benign analysis.
  7. Fix the CIP scope as availability engineering: circuits, coverage, cycle time, and chemistry, with the between-cleaning runtime targeted.
  8. Fix the verification evidence: guaranteed capacity and steam economy at stated conditions, per-effect heat balance, acceptance test protocol with turndown run, and the documentation pack.

Against neighboring separation equipment, the comparison a specifier actually runs is the following, and it belongs here rather than in the page title. Against forced circulation and rising film bodies, the falling film wins the heat-sensitive, clean-to-moderate-fouling band on temperature difference and residence, and loses fouling extremes to forced circulation's velocity and crystallizer geometries. Against the wiped-film and thin-film family, those mechanical machines own high viscosity, fouling, and small-scale strip duty at a price per square meter several times this machine's; below a few hundred centipoise they buy nothing the falling film does not do better. Against the flash tank, no competition: flashing separates vapor from hot liquid without heating surface, and appears inside this train's preheater recovery rather than against it. Against membrane concentration, reverse osmosis removes water without phase change at lower energy to a concentration ceiling; the two stack, RO first, evaporator to final solids, in most modern dairy and juice plants. Choose the architecture the viscosity, fouling class, and energy prices demand, not the one a supplier has on promotion.

The application map below turns those choices into a table the project file can carry into bid evaluation.

ApplicationConstruction to specifyCheck before order
Milk powder front end, 40 t/h waterMVR single effect or five-effect with TVRCrossed-line energy study at site prices
Juice concentrate, aroma criticalLow-temperature once-through, aroma recoveryMaximum 45 to 55 deg C; volatile spec in guarantee
Distillery stillage, 20 t/hFour-effect with forced finisherViscosity at final solids; anti-scalant program
Wastewater RO reject cutRecirculation, duplex last effect, TVRChloride at final effect; CIP hardness chemistry
Pharma extract concentrationSmall plate falling film or MVR, validated CIPDocumentation package to GMP expectation
Heat pump coupled specialty dutyPlate falling-film stage with heat pump loopCompressor duty and approach economics vs MVR

The RFQ block should be written once and reused. A complete block reads: feed composition and rate with fouling class; concentration pair and evaporation duty; product quality limits, maximum temperature and residence; energy prices, steam, power, cooling water, with annual hours; proposed architectures invited on one basis, effect counts and MVR; guaranteed capacity and steam economy at stated conditions; per-effect heat balance and operating temperatures; vacuum level and vacuum plant sizing basis with worst cooling water; calandria geometry, tube or plate, materials by effect with the last-effect chloride case; distribution design and turndown statement with wetting calculation; separator and demister arrangement; CIP circuits, chemistry, and cycle time; instrumentation list with online steam economy computation; acceptance test protocol including turndown demonstration; and documentation, process flow diagrams, heat balance, weld and material records, and the operating manual with startup and CIP procedures. A quotation returned without the heat balance or with wetting unstated is incomplete at any price.

Chapter 6 / 06

Installation, Standards, Failure Modes, and Maintenance

Installation is tall-plant engineering. Calandrias of 10 to 15 m arrive as vessels and stand in structures designed for their operating weight and the piping and access around them; distribution plenums are set level to tolerance, because a distributor out of level by millimeters starves the tubes on one side of the bundle; vapor ducts slope to drains so condensate never pools in a running line; and the vacuum plant, condenser, and preheater train are piped with the same discipline. Hygienic machines are installed to crevice-free standards with weld documentation, and the CIP skid is commissioned with the evaporator, not after it, because the first product run is scheduled after the first CIP proves.

Commissioning proves the heat balance and the wetting together. Water runs first: capacity at design rate, then the turndown demonstration with delta-T trended, then the vacuum plant at cold end design; the steam economy or MVR specific power is measured against guarantee on water before product ever enters, because water is the honest fluid and product arguments can wait their turn. Product trials then confirm quality limits, temperature and residence against spec, and the CIP cycle proves in its stated time budget with post-clean delta-T recovery verified. The acceptance record, capacity, economy, turndown stability, CIP recovery, is the baseline the plant trends for the decade.

The standards frame is hygiene and code by industry. Food, dairy, and pharmaceutical machines answer to hygienic design practice, 3-A and EHEDG conventions in their markets, with surface finish, cleanability, and weld documentation to match; pressure parts answer to the pressure vessel codes of the jurisdiction, ASME Section VIII or PED equivalents, as shell-side pressure vessels; and the vacuum and steam systems carry their own standards shadows. There is no single international evaporator standard because the machine is a process train of code parts and hygienic practice; the specification names the applicable set per subsystem, and the vendor's compliance statement is per line, not per brochure.

Failure modes follow a short, predictable list. Fouling of tubes and distribution, the defining failure: rising delta-T, falling capacity between CIPs, and the cure is wetting discipline, distribution maintenance, and CIP chemistry tuned to the deposit, calcium on dairy, protein and Maillard zones on stillage, silica on wastewater; a train that needs CIP every three days when it was sold at three weeks is a wetting or chemistry failure, not an operation problem. Entrainment and demister fouling: product losses to condensate and BOD spikes, cured by demister maintenance and foam control, antifoam dosing where the product tolerates it. Vacuum decay: air in-leakage through gaskets and seals grows, the vacuum plant runs hot, and every effect's temperature drifts up into the quality zone; a scheduled leak survey, the same helium discipline as any vacuum plant, holds it. Corrosion of the last effect and condenser, chloride concentration and CO2: alloy selection at order is the cure, and retrofit is expensive. MVR compressor fouling and vibration: wash systems and surge control are part of that machine's scope, and its maintenance follows compressor practice, not evaporator practice. Instrument drift: the steam economy computation is only as honest as its meters, and calibration is scheduled like the CIP.

Maintenance economics are CIP chemistry and wetting watch. Daily: read the per-effect delta-T and the computed steam economy, and log them; both are the fouling curve in real time. Per campaign: CIP with verification, post-clean delta-T recovery is the acceptance test of every clean. Quarterly: distribution inspection at the top tubesheet, demister wash, vacuum leak survey, and instrumentation calibration. Annually: internal calandria inspection, tube wall spot checks on the last effect, gasket and seal kit renewal, and the CIP chemistry review against the deposit actually found, because feeds drift and the chemistry that worked at commissioning is a starting point, not a law. A train with a clean delta-T history and a wetting-correct design runs its campaigns and cleans on schedule; the purchasing file that carries those histories writes the next RFQ from evidence, which is how it gets smarter instead of just older.

FAQ

What makes a falling-film evaporator gentler than other evaporator types?

The film and the small temperature difference. Liquid descends the heated wall as a 0.1 to 0.5 mm film, evaporation occurs at the film surface at 3 to 8 deg C driving force, and residence is one to three minutes, so the product never sees wall temperature and never dwells. Forced and rising film bodies need larger temperature differences and circulate product longer; wiped-film machines are gentle but mechanically complex. For heat-sensitive feeds the falling film is the default for exactly these numbers.

What is wetting rate and why does it decide my cleaning schedule?

Wetting rate is liquor flow per unit of tube perimeter, and it is the difference between a clean tube and a fouled one: below roughly 0.25 to 0.5 liters per second per meter of perimeter, depending on product, patches of the tube dry out, foul, insulate, and spread. The design must hold the floor at minimum feed, not just at design rate, which is why tube count, tube length, and turndown are one decision. An acceptance test that does not include a turndown run has not tested the machine's future.

Should I choose multiple effects or mechanical vapor recompression?

Run the crossed-line calculation at your own prices. Multi-effect trains reuse vapor body by body and reach steam economies of 4 to 5 in five effects, buying cheap water removal where steam is inexpensive. MVR compresses the whole vapor stream with electric power for effective economies of 10 to 30, winning where power is available and steam costly, at higher capital and a compressor to maintain. TVR ejectors buy roughly an effect's worth of economy cheaply where steam pressure exists. The RFQ should force all options onto one energy-price basis.

When is a wiped-film or thin-film machine the better purchase?

Above a few hundred centipoise, or when the feed fouls aggressively or strips volatiles at small scale, the mechanical rotor of a wiped-film evaporator spreads a film that gravity can no longer maintain, at several times the price per square meter. Below that viscosity, with a cleanable feed, the falling film does the same gentle evaporation at industrial scale and lower cost. The families are neighbors with different physics, not versions of one machine, and the viscosity and fouling class of the feed make the call.

How deep should the vacuum be, and what holds it?

Product sensitivity sets the boiling temperature, 45 to 80 deg C typical, and the corresponding vacuum, roughly 50 to 200 mbar absolute. What holds it is the condenser plus the air removal system, a steam ejector train or a liquid-ring vacuum pump, sized against air in-leakage and dissolved gases at the worst-season cooling water temperature. Size the vacuum plant for the hot afternoon, not the annual average, because capacity and product temperature both drift up with every degree the condenser loses.

How do I keep a falling-film train clean between CIP cycles?

Three levers: wetting discipline at every turndown, distribution kept level and unblocked, and CIP chemistry matched to the actual deposit, calcium films on dairy, protein and sugar zones on stillage, silica on wastewater. The operating evidence is the per-effect delta-T trend and the computed steam economy, logged daily; when either drifts, the machine is asking for its clean. Post-clean delta-T recovery is the acceptance test of every CIP, and a chemistry review against the deposit actually found belongs in the annual program.

Can a falling-film evaporator handle crystallizing or high-solids feeds?

Only up to the point where solids stay dissolved and pumpable. Concentrating into supersaturation drops crystals into the bundle and turns the calandria into a fouling campaign; those duties belong to forced-circulation bodies and dedicated crystallizer designs, with a small forced finisher after the falling-film train as the common hybrid. Specify the viscosity and solids at final concentration honestly, and the process engineer draws the boundary where the physics puts it.