An impeller is the rotating element of a fan, blower or compressor: a hub or disk that carries the vanes and, when the shaft turns it, draws air in at the eye and delivers it outward with more energy than it had at the inlet. In centrifugal machines the impeller is also called the wheel, and more than any other part it decides what the machine can do. Blade shape sets the character of pressure, flow and power. Diameter and width set the size of the duty. Material and construction set the temperature and speed ceiling. Balance sets how smoothly the whole assembly will run. A centrifugal fan is a wheel working inside a scroll housing, and the impeller is its working heart and its most highly stressed part.
The impeller is bought in two ways. A machine builder orders wheels in batches and builds the housing, shaft, bearings and drive around them. A plant engineer orders a single replacement wheel for a fan that has lost performance, cracked a blade or begun to shake, and that wheel has to agree with the old one in diameter, width, rotation, bore and blade count. In both cases the specification is short and unforgiving: wheel size, blade type, material, rotation, bore and mounting, duty point and speed limit. A wheel ordered wrong in any one of these does not fail gently. It will not go on the shaft, it will not deliver the duty, or it will shed a blade at speed.
Diagram: SpecForge original drawing of the three centrifugal impeller blade types, made for this page.
Four things decide an impeller purchase. First the blade type, because forward-curved, radial and airfoil wheels are three different characters in one family, with different pressure, dirt tolerance and power curves. Second the geometry: diameter, width, blade number and bore, which fix the duty point and the fit on the shaft. Third the material and construction, which set the temperature, corrosion and tip speed limits. Fourth the balance and the mounting, because a wheel that is true on the balancing machine can still shake once it is forced onto a worn or bent shaft.
Chapter 1 / 06
What an Impeller Is and How It Works
An impeller has three working parts. The hub is the central boss that fits on the shaft and carries the whole load. The blades, or vanes, stand out from the hub and do the work on the air. The back plate, and in a shrouded wheel the front shroud as well, ties the blades into one stiff body and guides the air between them. The eye is the opening at the inlet through which air enters. The tip is the outermost circle traced by the blade edges, and the impeller diameter is the maximum distance across the wheel measured over those tips. Inside a centrifugal fan the wheel sits within a scroll, the spiral housing that collects the air leaving the tips.
The blades do work on the air and the housing turns that work into pressure. As the wheel turns, each blade carries air outward and the air speeds up from hub to tip. In a centrifugal wheel that gain is kinetic energy: the air leaves the blade tips at high velocity. The scroll then widens toward the outlet, the air slows down, and its velocity is exchanged for static pressure. An airfoil or backward-inclined blade also acts as a wing and generates lift, so part of the pressure rise is already present when the air leaves the blade. The share of the shaft power that arrives in the moving air is the efficiency of the wheel and its housing together, because a bare wheel cannot slow the air down by itself.
Tip speed links the geometry to both duty and danger. It is the peripheral speed of the blade tips, found by multiplying the circumference of the impeller by its rotational speed, and it sets both the pressure rise and the centrifugal load on the wheel. Since pressure follows the square of speed, a small rise in revolutions buys a large rise in pressure and an equally large rise in stress. The angle at which a blade releases its air sets how much of the energy leaves as velocity, and so how fast a wheel must turn for a given pressure. A forward-curved wheel runs at a relatively low speed for its duty, which keeps its stress and noise low and lets it be small for the flow it moves.
Four quantities describe what an impeller delivers. Flow rate is the volume of air moved per unit of time, taken at the inlet. Pressure is stated as total pressure, the sum of static pressure and velocity pressure, or as static pressure alone. Shaft power is the mechanical power that reaches the wheel, and the motor, belts and bearings must all be sized to carry it. Efficiency is the power in the air divided by the shaft power: total pressure multiplied by flow rate, divided by shaft power and a unit conversion constant. Static efficiency is the same ratio built on static pressure alone, so a buyer should always know which of the two a catalog is quoting.
The fan laws let one measured curve describe a whole family of running conditions. For a fixed wheel in a fixed system, flow varies directly with rotational speed, pressure with the square of speed, and power with the cube of speed. Reducing the speed by 20 percent therefore cuts power by half. Geometrically similar wheels scale by size in the same spirit, with flow following the cube of diameter, pressure its square and power its fifth power. The laws assume exact similarity, which real wheels only approach, so the ISO fan standards restrict the conversions they permit and give tolerances for performance data converted from one speed, gas or size to another.
In operation the wheel meets the duct system and settles at one point. Air enters the eye along the axis, turns into the passages between blades and leaves near the tips at an angle set by the blade. The flow stops rising when the pressure the wheel adds equals the resistance the system puts up, and that meeting point moves if a damper, a filter or the wheel speed changes. The wheel also stores energy as it spins: a large one holds high rotational inertia, so the motor must supply starting torque as well as running power, and the starting current of most motors runs 2 to 5 times the running current. Starting against a closed damper lightens that load on most centrifugal wheels.
Chapter 2 / 06
Impeller Types and Structural Variants
Blade shape sorts impellers into families. A forward-curved wheel has short blades that curve toward the direction of rotation. It moves low to medium volumes at low pressure, runs slowly and stays compact, and its efficiency is only 55 to 65 percent. Its power rises steadily as flow increases, all the way to free delivery, so the motor needs generous margin. A radial-blade wheel has flat blades running straight out from the hub. It delivers low to medium flows at high pressure, its plain blades give dust little to hold on to, and the open passages let it run at low flow without the shaking that stalled wheels usually show. It is the rugged choice for particulate, fibrous and hot air, and it takes protective coatings well.
A radial-tip wheel sits between the two: its blades are shallow, with trailing edges that point out from the axis, it tolerates small particulates and moisture, and it reaches efficiencies up to 75 percent. Backward-inclined wheels lean away from the direction of rotation and come in three blade forms. Flat blades are the most robust. Curved blades run more efficiently. Airfoil-section blades are the most efficient of all, above 85 percent, but they are thin-walled, erode quickly in dusty air and stall sharply when run too far up their curve. Their power rises with flow for most of the curve and then drops, so the motor is not overloaded near free delivery, which suits systems whose behavior at high flow is uncertain.
Construction and mounting vary independently of blade shape. An open wheel has its blades fixed to a back plate with nothing joining the tips; it is the plain form of a fabricated radial wheel and is easy to clean and to coat. A shrouded wheel adds a front ring that links the blade tips and leads air into the passages. Pressure-blower wheels are made in either style. A single-width, single-inlet wheel takes air from one side; a double-width, double-inlet wheel is two wheels back to back on one hub and takes air from both sides. In the standard drive arrangements the impeller is overhung on its own bearings or on the motor shaft, or carried between two bearings supported by the housing; belt-driven wheels ride on a fan shaft between two pillow block bearings.
The high-pressure end of the family works on different principles. A regenerative blower impeller is a ring of many straight blades running in a narrow channel, each blade striking the same air repeatedly as it circles the housing, so the energy adds up over many passes. An air stripper at the base of the housing diverts the air out of the channel, slowing it and turning its speed into pressure. These impellers are cast in aluminum and dynamically balanced, then fitted directly on a two-pole motor shaft, in single or two-stage form, and their motors accept a variable frequency drive. Multistage centrifugal blowers stack several wheels in series on one shaft so that pressure rises stage by stage, and a turbo blower spins one wheel at very high speed.
Materials follow the air and the speed. General-purpose wheels are fabricated from sheet steel: blades cut and formed, then welded to the back plate and hub, with hot-dip galvanized or coated finishes where moisture is present. Aluminum alloy wheels are lighter, which lets them run faster for the same stress, and they serve in spark-resistant construction, although their temperature ceiling is lower. Stainless steel wheels take corrosive fume exhaust, and fiberglass and other composite wheels take aggressive chemistry at moderate size and speed, since composites and plastics have limits of both. Radial and backward-curved wheels are also cast in aluminum rather than fabricated. For hazardous atmospheres, wheels are built from nonferrous alloys so that metal touching metal cannot strike a spark, and the whole rotating assembly is grounded.
An impeller is a part, and the line around it is drawn by the machine it sits in. The centrifugal fan, the pressure blower and the industrial blower are complete machines, each with its housing, shaft, bearings and drive, and the impeller is the wheel inside them. A Roots blower is not in this family: its lobes push air through without centrifugal action. The same word serves turbomachines for other fluids, where the impeller of a centrifugal pump or a centrifugal compressor is a close cousin built to tighter clearances. The stacked blade rows of an axial compressor form a rotor rather than an impeller. The axial wheel of a tubeaxial or vaneaxial fan is an impeller too, with air leaving along the axis instead of outward.
Chapter 3 / 06
Impeller Key Specification Parameters and Standards
An impeller datasheet is a short list of geometry and duty. The wheel size is its diameter and width: industrial centrifugal wheels run from about 155 mm to 2,500 mm (6 to 98 in) in diameter, and a given diameter comes in several widths to move more or less air. Blade number and blade angle fix the character described above, with backward-inclined airfoil plenum wheels built with 9 or 12 blades. The hub ratio, the hub diameter expressed as a fraction of the wheel diameter, sets the eye area and the inlet velocity. The running clearance between the wheel and the inlet cone is kept small and even, as a rule of practice, because a wide or uneven gap lets air leak back from the pressure side to the inlet.
Around the geometry sit the duty ratings. Flow rate and pressure define the duty point, and the shaft power at that point sizes the motor. Maximum speed is a hard rating for each wheel size and construction, because the centrifugal load grows with the square of speed and every metal weakens as it heats, so a hot duty lowers the speed allowed. Temperature limits depend on material: aluminum construction is suitable up to 250 degrees Fahrenheit (121 degrees Celsius), while 316 stainless steel backward-inclined wheels are offered for air up to 1,000 degrees Fahrenheit (538 degrees Celsius). The balance grade, commonly G6.3 for packaged centrifugal wheels, states the residual unbalance. The bore, keyway and mounting hardware decide the fit.
Standards divide along the line between testing and running. ISO 5801 is the laboratory test for fan performance: it covers fans of all types except those designed solely for air circulation, such as ceiling and table fans and air circulators, and it gives the rules for converting test results for changes in speed, gas and size within limits. ISO 13348 sets the tolerances on that performance and how technical data are presented, by installation category, from free inlet and free outlet to ducted inlet and ducted outlet. For the running wheel, ISO 14694 specifies balance quality and vibration limits for fans below 300 kW (400 hp), ISO 14695 gives the method of measuring fan vibration, and ISO 21940-11 governs the balancing of rigid rotors in general, having replaced the long-cited ISO 1940-1. AMCA standards play the same roles in North America.
Selecting an impeller is a sequence of conversions: the duty into a wheel size and speed, the air conditions into corrections, the speed into a stress check, and the running point into a stability check. Each step narrows the choice before a price is requested.
Start with the duty: the flow rate and the pressure the system needs at the wheel, at the actual temperature and altitude. The operating point is where the pressure curve of the wheel crosses the resistance curve of the system, and the wheel should be chosen so that this point falls near the best efficiency point, to the right of peak pressure. One useful index is specific speed, a combination of rotational speed, flow and pressure that sorts wheels by geometry: low values point to narrow radial wheels, high values to wider wheels that pass more flow. The ISO fan standards use specific speed to bound the efficiency scaling they allow.
Once a wheel is close to the duty, the fan laws finish the selection. If the measured or catalog curve belongs to one speed, the laws move it to another: flow in proportion to speed, pressure with its square, power with its cube. A wheel that overshoots the duty can be slowed down instead of replaced, and a 20 percent speed reduction removes half the power. The same arithmetic sizes the motor over the whole speed range, because the power at the top speed, not the duty point, sets the rating. The laws apply to a wheel in a fixed system; a change of damper setting, duct run or inlet condition shifts the resistance curve and moves the operating point on its own.
Performance data assume standard air: a density of 0.075 pounds per cubic foot, dry air at 70 degrees Fahrenheit (21 degrees Celsius) and 29.92 inches of mercury. Hot air and thin air are lighter, so a wheel moving them delivers the same volume and speed but less pressure and needs less shaft power. To select from a standard-air curve, the required pressure is first scaled up by a conversion factor. One worked case: 1,500 cubic feet per minute at 8.6 inches of water, at 200 degrees Fahrenheit (93 degrees Celsius) and 7,000 feet (2,100 m). The factor is 1.63, so the wheel is picked at about 14 inches of water on the standard-air curve, while the motor at temperature needs only about 3.2 brake horsepower, where a 5 hp motor will do.
Speed is checked against the wheel, not only against the duty. Every wheel size and construction carries a maximum speed, set by the stress its material can take at the blade tips and at the blade roots, and that figure must never be exceeded. The check grows stricter as air temperature rises, because metals weaken with heat and a wheel safe on cold air can be unsafe on hot exhaust. Makers publish maximum temperatures for each wheel type, and high-temperature versions keep bearings out of the air stream or fit a heat slinger on the shaft. Fan classes add a second scale: a class states the outlet velocity and pressure a construction is built to carry, with heavier material, larger shafts and larger motors as the class rises.
Last come stability and drive. A forward-curved, backward-inclined airfoil or axial wheel has an unstable region to the left of its pressure peak, where it hunts and pulsates, so the duty should sit to the right of that peak with margin at every operating speed. Belt drive with V-belts gives speed adjustment by changing sheave diameters and keeps the motor out of hot or dirty air. Direct drive puts the wheel on the shaft of an AC motor and limits speed to within a few percent of the motor's synchronous speed, so speed variation then comes from a variable frequency drive, which must skip any resonant speed of the fan and its supports. On larger units the motor drives the fan shaft through a shaft coupling. A soft starter, or a closed damper at start-up, limits the shock on wheel and motor.
Selection factor
What to verify
Why it matters
Duty point
Flow and pressure in the actual air, with temperature and altitude
Sets the wheel size and speed
Position on the curve
Right of peak pressure, near the best efficiency point
Stable flow, low noise, low wear
Air cleanliness
Radial or radial-tip for dust; airfoil for clean air
Build-up, erosion and balance life
Air temperature
Speed derating and wheel material by temperature
Wheel strength and bearing life
Pressure class
Construction class for outlet velocity and pressure
Material gauge, shaft and motor size
Power character
Overloading forward-curved curve needs motor margin
Motor heating toward free delivery
Speed control
Fan law range; skip resonant speeds
Drive and motor selection
Drive type
Direct drive for fixed speed; belts for speed trim
Maintenance load and speed flexibility
Installation category
Ducted or free inlet and outlet, stated with the data
Whether rated performance is reached
Chapter 5 / 06
Impeller Installation, Maintenance and Failure Modes
An impeller rarely fails on its own. It fails from the way it was mounted, from the air it was asked to move, or from the speed and temperature at which it was run. Most of the work that keeps a wheel in service happens at installation and on short scheduled inspections.
Mounting is where a good wheel is most often spoiled, so checks begin before it goes on: rotation confirmed as clockwise or counterclockwise seen from the drive side, the stated maximum speed above the running speed, balance weights present and secure. The bore must fit the shaft closely, the shaft key must sit in both keyways without rocking, and the hub must seat against a shaft shoulder or a shaft collar rather than against the key alone. Where a taper bush or a locking assembly grips the wheel, the screws are tightened evenly in stages so that the bush draws in square, and set screws are torqued to the maker's value. A dial indicator on the hub and tips then shows whether face and rim runout are within tolerance, and the gap to the inlet cone is set all round.
The inlet decides how much of the wheel's capacity is used. The running gap between the wheel and the inlet cone must be even, because a wide or uneven gap lets air leak back from the pressure side. Beyond the inlet, the ductwork should bring the air in straight and without spin: a spin in the same direction as the wheel cuts volume and pressure, and a spin against rotation raises the motor load. Good practice keeps at least 3 wheel diameters of straight duct on the outlet, 4 wheel diameters between outlet and elbow, and 1 wheel diameter between an unducted inlet and a wall. An abrupt outlet can lose up to 20 percent of the air volume, and none of that loss shows up as a fault in the wheel.
Start-up is a controlled sequence. Bump the motor and confirm rotation, then run the wheel and listen: a scrape means the tips are touching the housing or the inlet cone. Measure speed with a tachometer and pressure with a manometer or pressure gauge, and set the readings beside the curve. On larger units a vibration sensor sits on the bearing housings, a portable vibration analyzer is used on periodic routes, and the readings are judged against the limits of ISO 14694. Vibration at the running frequency points to unbalance or to a wheel off center. A tone at blade-pass frequency, the rate at which the blades pass the cut-off or another fixed object, points to wheel design or duct layout rather than to balance.
Balancing and cleaning are the two routine jobs. A wheel is balanced statically and dynamically before delivery, to grade G6.3 in packaged units, on a dynamic balancing machine with correction in two planes; balancing in its own bearings on site is a last resort for a wheel that cannot be removed. Dust and moisture collect unevenly on the blades and throw the wheel out of balance, most on airfoil blades and least on radial types. Erosion thins the blades and can open cavities in hollow airfoil sections, corrosion attacks welds and blade roots, and long running in stall or at a resonant speed cracks the blade roots. Light build-up is washed or blasted off and the wheel is then rebalanced; a wheel with thinned or cracked blades is replaced, not patched.
Isolate the motor, lock out the drive and let the wheel come to rest.
Mark the wheel position on the shaft and record the gap between wheel and inlet cone.
Release the set screws, taper bush or locking assembly and withdraw the wheel with a puller on the hub, never by pulling on the blades.
Clean and inspect the shaft, key and inlet cone; refit the new wheel in the marked position, restore the gap, tighten in stages to torque, turn by hand, then bump-test the rotation.
Symptom
Probable cause
Action
Vibration at running frequency
Blade build-up, lost balance weight, bent hub, wheel off center
Clean and rebalance; check bore fit and runout
Falling flow and pressure
Blade build-up, worn tips, inlet gap too large, inlet spin
Clean; reset gap; add straight duct
Rising motor current
Overloading forward-curved curve; inlet spin against rotation; denser air
Check the curve, the inlet and the speed
Pulsing or hunting flow
Running in stall, left of the pressure peak
Move duty or speed; add a bleed
Cracks at blade roots
Fatigue from resonant speed or stall
Skip the speed; replace the wheel
Holes in airfoil blades
Erosion by dust
Fit radial-tip wheel; add blade liners
Rust at welds
Corrosive or moist air
Coat; change to stainless steel or composite
Scraping noise
Tips touching housing; shaft loose in bore; bearing wear
Reset gap; check fit and bearings
Chapter 6 / 06
Impeller Industry Applications and Procurement Checks
Impellers serve wherever air has to be moved against resistance. Heating, ventilating and air conditioning uses forward-curved and backward-inclined wheels in air handlers, rooftop units and furnace blowers, where the air is clean and the pressure low. Dust collection and the carrying of granular solids call for radial and radial-tip wheels in pressure blowers. Boilers, kilns, dryers and furnaces take large backward-curved and airfoil wheels as forced-draft and induced-draft fans, often in high-temperature construction. Corrosive fume exhaust runs on stainless steel, coated or composite wheels. Regenerative blowers supply oil-free, pulsation-free air at pressures built up over many blade passes, in food processing, pharmaceutical, medical and environmental equipment. In flammable atmospheres, wheels of nonferrous alloy are built and grounded so that they cannot set off the air they move.
Cost follows material, size and work content more than blade shape. A welded sheet steel wheel is the baseline, and its price rises with diameter and width because more material, more welding and a larger balancing machine are needed. Stainless steel, nonferrous alloy and composite wheels cost more per kilogram and take longer to form. A cast aluminum wheel carries tooling cost, so it suits standard sizes made in quantity. Beyond the wheel itself, the buyer pays for the accuracy of the bore and keyway, a tighter balance grade, coatings and liners, spark resistant construction, and any performance test, overspeed test or balance record. Lead time is short for standard catalog wheels and long for special widths, special materials and large diameters welded and balanced to order.
Acceptance is a matter of documents and one run test. A supplier should be asked for the pressure, power and efficiency curve at the stated speed and air density, with the tolerance class and the installation category named, because a wheel rated with a free inlet will not repeat that rating on a poorly ducted one. The balance certificate should state the grade, and on larger or vibration-sensitive units the assembled fan should be measured by the method of ISO 14695 against the limits of ISO 14694. Material certificates matter where the air is corrosive or the atmosphere flammable. Rotation, bore, keyway and maximum speed belong on the drawing and are checked at goods-in. A spare wheel held on site is inexpensive insurance for a fan whose stoppage stops a line.
When an impeller is ordered, the purchase order should state, in this order: the wheel diameter and width; the blade type and blade count; the material and any coating, liner or spark resistant construction; the rotation, clockwise or counterclockwise as seen from the drive side; the bore diameter, keyway size and mounting method, whether plain with a key, a taper bush or a locking assembly; the duty point of flow and pressure at the actual air temperature, altitude and dust load; the running speed and the maximum speed allowed for the wheel; the balance grade; the temperature limit; and the standards the performance data shall meet. The buyer should ask in return for the performance curve with its tolerances and installation category, the maximum speed and temperature in writing, a balance certificate, a material certificate where the air demands it, the gap to be held between wheel and inlet cone, and the recommended inspection interval for the duty. A dimensioned sketch of the old wheel, with hub, bore and keyway measured, removes most of the doubt from a replacement order.
FAQ
What is an impeller on a fan or blower?
An impeller is the rotating part of a fan, blower or compressor: a hub or disk that carries blades and, when the shaft turns it, takes air in at the eye and delivers it outward with more energy. In centrifugal machines it is also called the wheel. The blades add velocity to the air, and the scroll or housing slows the air so that velocity becomes pressure. Blade shape, diameter, width, material and balance decide how much air the wheel moves, at what pressure and at what power. A centrifugal fan is the complete machine; the impeller is the part inside it that does the work.
What are the main impeller blade types?
Five blade types cover most fan and blower wheels. Forward-curved wheels have short blades curving toward rotation, run slowly, suit clean low-pressure air and reach 55 to 65 percent efficiency, with power that keeps rising as flow rises. Radial-blade wheels have flat blades, take high pressure and dusty or stringy air, and shed build-up. Radial-tip wheels suit fine dust and moisture and reach up to 75 percent. Backward-inclined wheels lean away from rotation and come as flat, curved or airfoil blades; flat is the most robust and airfoil the most efficient, above 85 percent, but thin and prone to erosion, with power that peaks and then falls.
Which impeller specifications matter most?
Start with wheel diameter and width, which must match the housing and the flow. Then blade type and blade count, which fix the pressure and power character. Then the material, which sets the temperature limit: aluminum construction up to 250 degrees Fahrenheit (121 degrees Celsius), 316 stainless steel backward-inclined wheels up to 1,000 degrees Fahrenheit (538 degrees Celsius). Then the mounting: bore, keyway, hub and whether the wheel is overhung on the motor shaft or carried on fan bearings. Then the balance grade, commonly G6.3. Finally the maximum speed, never to be exceeded, and the rotation, clockwise or counterclockwise as seen from the drive side.
How do I choose the right impeller for a duty?
Begin with the flow and pressure the system needs at the actual air temperature and altitude, and convert that pressure to standard air before reading a catalog curve. Pick a wheel whose pressure curve passes through the duty near its best efficiency point, to the right of the pressure peak, with margin at every operating speed. Use radial or radial-tip wheels for dust and moisture, and backward-inclined or airfoil wheels for clean air. Apply the fan laws to any speed change: flow with speed, pressure with its square, power with its cube. Check the speed against the wheel's maximum at temperature, and size the motor for the top of the speed range.
How is an impeller mounted and balanced?
The wheel is balanced before it leaves the maker, usually in two correction planes on a dynamic balancing machine, to a grade such as G6.3. Mounting must not undo that work. The bore must fit the shaft closely, the key must sit in both keyways without rocking, and the hub must seat on a shaft shoulder or collar. A taper bush or locking assembly is tightened in stages so that it draws in square, and set screws are torqued to the maker's value. After mounting, runout at the hub and tips is checked with a dial indicator and the gap to the inlet cone is set even all round.
What drives the cost and lead time of an impeller?
Diameter and width come first, since a large wheel needs more material, more welding and a larger balancing machine. Material comes next: coated sheet steel is the baseline, and stainless steel, nonferrous alloy and composite wheels cost and take more. Accuracy adds cost, because a finely bored and keywayed hub, a tighter balance grade and coatings or liners are extra operations, as are tests such as a performance curve to ISO 5801 with tolerances to ISO 13348, an overspeed test or a vibration run. Lead time is shortest for standard catalog wheels and longest for special widths, special materials and wheels welded and balanced to order.
What causes impeller failure and how is it prevented?
Most impeller failures begin with the air or with mounting. Dust and moisture collect unevenly on the blades and throw the wheel out of balance. Erosion thins blades and opens holes in hollow airfoil sections, corrosion attacks welds, and long running in stall or at a resonant speed cracks blade roots. A wheel forced onto a bent shaft runs out of true and shakes from the first day. Prevention is regular cleaning and rebalancing, the right blade type for the air, inspection of blade roots and welds, vibration readings judged against ISO 14694, and strict respect for the maximum speed and temperature. A wheel with thinned or cracked blades is replaced, not patched.