A sulfur recovery unit, SRU, is the plant that converts the hydrogen sulfide in acid gas, the stream an amine unit strips out of raw natural gas or refinery gas, into elemental sulfur, almost always by the Claus process: a third of the hydrogen sulfide burns to sulfur dioxide in a hot reaction furnace, and the remaining hydrogen sulfide reacts with that sulfur dioxide over alumina catalyst in one, two, or three converters to make sulfur and water, with a condenser after each stage dropping liquid sulfur into the pit. Where regulations demand more than the roughly 94 to 97 percent a conventional Claus train recovers, a tail gas treating unit finishes the job and pushes total recovery above 99.5 percent. The US EPA's AP-42 Section 8.13 on sulfur recovery documents the process and its emissions, and Worley Comprimo's sulfur technology lines are representative of the licensors building these plants, and this page treats the complete SRU train as the purchasing object.
This page is written for the process engineer specifying a sulfur recovery unit for a gas plant, refinery, or sour gas development. It works through what the plant does and what is being bought, how the furnace and the converters do the work, which stage counts and tail gas configurations fit which requirements, the parameters that appear on licensor data sheets, and the selection factors and RFQ language that decide whether the plant meets its recovery guarantee and its sulfur dioxide permit.
The decision concentrates in five places: the acid gas rate and composition, especially hydrocarbon and ammonia contaminants; the recovery efficiency and sulfur dioxide limit the permit demands, which fix the stage count and tail gas choice; the air control and oxygen enrichment strategy that sets furnace behavior; the sulfur handling, condensers, pit, degassing, and transport; and the integration with the amine unit upstream and the tail gas incineration downstream. Get those right and the vessel sizes, catalyst volumes, and burner duty follow.
Chapter 1 / 06
What a Sulfur Recovery Unit Is and What Is Being Decided
The machine this page describes is a reaction furnace train. Acid gas from the upstream amine unit, hydrogen sulfide with carbon dioxide, water, and traces of hydrocarbons and ammonia, burns with a controlled airflow in a refractory lined furnace at 950 to 1400 degrees C, where a third of the hydrogen sulfide oxidizes to sulfur dioxide and some sulfur forms directly; the hot gas then cools through a waste heat boiler and the first sulfur condenser, dropping liquid sulfur, and passes through two or three catalytic converters, alumina beds at 200 to 350 degrees C, where the Claus reaction, hydrogen sulfide plus sulfur dioxide yielding sulfur and water, deposits more sulfur at each stage. Condensers between stages drop the sulfur to the pit; the unreacted fraction leaves as tail gas to incineration or treating.
What is being decided when a sulfur recovery unit is purchased is a recovery guarantee and a sulfur dioxide mass limit, together at a stated acid gas feed. The buyer is purchasing a stated percent of the inlet sulfur recovered as product sulfur, commonly 96 to 97.5 percent for a three stage Claus, above 99.8 percent with tail gas treating, with the unrecovered fraction leaving as sulfur dioxide within the permit, and with turndown and availability numbers that decide how often the plant flares or vents instead. Everything on the licensor data sheet, furnace temperature, stage count, catalyst volumes, condenser areas, tail gas configuration, exists to support those guarantees, and the honest licensor sizes from the acid gas analysis including its contaminants, not from a sulfur rate alone.
The SRU sits in the sour gas chain with defined neighbors. It is not the amine unit, which strips the acid gas out of the raw gas upstream; that page already sends its acid gas to Claus sulfur recovery as the downstream destination, and this page is that destination. It is not the flare stack, which destroys streams by combustion in upset and startup, and whose smokeless assist, steam or air, is a different art. It is not a thermal oxidizer or catalytic oxidizer, which destroy remaining tail gas contaminants by combustion, though the tail gas incinerator is exactly such a unit at the SRU's back end. And it is not a steam methane reformer or any hydrogen plant; the chains are neighbors in a refinery but share no process.
Different buyers buy the same plant for different products. A gas plant buys an SRU to sell liquid sulfur from a sour field's acid gas, valuing recovery above everything because every unrecovered tonne is a permit tonne. A refinery buys an SRU to destroy the amine acid gas plus sour water stripper gas, with ammonia destruction in the furnace a hard requirement. A very sour development buys oxygen enriched Claus to keep furnace temperature in range at high hydrogen sulfide content. A small remote field buys a liquid redox or direct oxidation alternative below the Claus scale. The specification language differs, but the Claus chemistry is shared.
The economics deserve their own paragraph because sulfur is a byproduct with a price and a penalty at once. Product sulfur, degassed and solid or liquid, sells into acid and fertilizer markets at prices that rarely pay the plant but soften its cost; the unrecovered fraction, by contrast, is sulfur dioxide the permit prices in emission units and public attention. Recovery efficiency is thus the commercial heart: the step from 96 to 99.8 percent, a tail gas unit, is bought against the permit, and the step from poor to good air control is bought in catalyst life and availability. The honest comparison prices recovery, permit headroom, turndown, and availability together, and the cheapest train that meets today's number with no margin is usually the most expensive plant in the portfolio's future.
A short tour of named duties makes the plant concrete. At a gas plant, 40 tonnes per day of acid gas sulfur runs a three stage Claus with a tail gas hydrogenation unit and amine recycle, recovering 99.9 percent. At a refinery, acid gas plus sour water stripper gas with ammonia feeds a two stage Claus with oxygen enrichment and incineration, recovering 96 percent within its permit. At a small field, 5 tonnes per day runs a straight through three stage Claus with no tail gas unit, meeting a 98.5 percent recovery requirement. Each duty names the same knobs, stages, enrichment, tail gas, and sulfur handling, with numbers that scale while the chemistry barely changes.
Chapter 2 / 06
How the Furnace and the Converters Do the Work
The chemistry is two reactions in sequence. In the reaction furnace, combustion air burns a controlled third of the hydrogen sulfide to sulfur dioxide, 2 H2S plus 3 O2 to 2 SO2 and 2 H2O, at flame temperatures that also crack ammonia and destroy contaminants; the H2S to SO2 ratio is controlled to exactly 2 to 1, the stoichiometry the downstream reaction needs. Then the Claus reaction, 2 H2S plus SO2 to 3 S and 2 H2O, runs first in the furnace's cooler residence and then over activated alumina catalyst in each converter, and because it is equilibrium limited and exothermic, each converter runs cooler than the last, 320 down to 200 degrees C class, to push the equilibrium toward sulfur.
Air ratio control is the plant's daily discipline. Too much air leaves surplus sulfur dioxide in the tail gas and suppresses conversion; too little leaves hydrogen sulfide breakthrough and sulfur contamination in the product; the operator trims the airflow on tail gas analyzer, tracking the H2S to SO2 ratio at 2 to 1 continuously, and the furnace burner's mixing governs whether that ratio holds across the flame. Contaminants make the furnace harder than the converters: hydrocarbons above design make soot and lay down carbon on catalyst, ammonia needs residence time and temperature to destroy or it salts the downstream as ammonium salts, and water in the acid gas dilutes the furnace and shifts equilibria. The acid gas analysis is thus the single most important input to the design.
The converters and condensers alternate down the train. Each converter is a fixed bed of activated alumina catalyst, sometimes titania promoted for the last stage's hydrolysis duty, running adiabatically with inlet reheat, hot gas bypass, indirect exchanger, or direct fuel firing, to hold its temperature window; after each converter a sulfur condenser, a shell and tube heat exchanger class unit generating low pressure steam, cools the gas below the sulfur dew point so liquid sulfur drains to the pit and the next converter sees gas with the sulfur removed. The last condenser runs cold enough, 130 to 160 degrees C, to catch the final fraction, and the gas leaves as tail gas with everything not yet recovered.
Sulfur handling is its own discipline because liquid sulfur is a strange fluid. It drains from condensers at 130 to 160 degrees C through steam jacketed lines, sulfur freezes at 119 degrees C and every line and valve jacket exists to prevent that, into the sulfur pit or tank where it holds at 135 to 150 degrees C; dissolved hydrogen sulfide in pit sulfur is degassed, by air stripping or catalyst assisted routes, before the sulfur is pumped to storage, rail cars, or solidification, both for safety and for product specification. Steam tracing quality, jacketed valve reliability, and pit management are unglamorous details that decide whether the plant runs or plugs.
The tail gas decides the plant's recovery class. A straight Claus train burns its tail gas in an incinerator, a thermal oxidizer, and recovers only what the converters caught. A tail gas treating unit first hydrogenates the tail gas, converting all sulfur species, SO2, COS, CS2, back to H2S over a cobalt molybdenum catalyst, then recovers that H2S with a selective amine and recycles it to the furnace, pushing overall recovery above 99.5 to 99.9 percent; other routes oxidize or directly treat at smaller scale. The choice is the permit's: the recovery class bought must clear the emission limit with margin at worst case feed.
Monitoring and safety close the story. Tail gas analyzers run the air ratio control, and gas detection watches the hydrogen sulfide population, because the SRU is the plant's most toxic neighborhood: hydrogen sulfide at lethal concentrations is present at many points, and the design's ventilation, detection, and escape philosophy is a license to operate. The incinerator or oxidizer stack carries the sulfur dioxide that the permit measures, and its continuous monitoring is the recovery guarantee's public witness. A plant that controls its ratio, its temperature windows, and its sulfur jackets meets its guarantee; a plant that ignores any of the three meets its emergency procedures instead.
Chapter 3 / 06
Claus Stages, Tail Gas Treating, and Duty Boundaries
Configuration choice begins with stage count and tail gas route. Two catalytic stages recover roughly 92 to 95 percent, three stages 94 to 97.5 percent, the standard refinery and gas plant train; four stages add a point or so and rarely justify themselves against a tail gas unit. Where the permit demands better, the tail gas treating choice follows: hydrogenation plus selective amine recycle, the dominant route above 99.5 percent; direct oxidation or sub dew point Claus variants at specific conditions; and incineration only where the permit tolerates the unrecovered fraction. Oxygen enrichment, air enrichment to 30 to 100 percent oxygen, buys turndown and temperature range on rich or small trains, and process variations such as split flow and direct oxidation place the furnace duty where lean acid gases need it.
Configuration
Recovery class
Typical fit
Two stage Claus plus incinerator
92-95%
small train, lenient permit
Three stage Claus plus incinerator
94-97.5%
the standard train
Oxygen enriched Claus
as train plus range
rich acid gas, turndown
Claus plus TGTU hydrogenation and amine
99.5-99.9%+
tight sulfur dioxide permit
Sub dew point and direct oxidation
97-99.5%
specific lean and retrofit duties
Duty boundaries keep the selection honest. The Claus train wants acid gas, not fuel gas: hydrocarbon above a few percent soots catalyst and derates the furnace, and the amine unit's performance upstream is part of the SRU's feed guarantee. Ammonia from sour water strippers must be destroyed in the furnace, demanding temperature and residence, or it salts the condensers; aromatics and heavy hydrocarbons are the classic catalyst poisoning story. Below roughly 1 to 2 tonnes per day of sulfur, Claus economics fade and liquid redox or scavenger alternatives take the duty; at extreme scale, oxygen blown variants carry the tonnage. Within its band, the Claus process is the industry's sulfur machine with no serious rival.
Where it sits in the chain matters as much as the train. Upstream, the amine unit delivers the acid gas, its regenerator overhead knockout drum catching liquids, and a sour water stripper may join its gas to the same furnace; fuel gas and combustion air, plus oxygen if enriched, feed the burner through a fired heater style management system. Downstream, the tail gas route, incinerator with its stack or hydrogenation reactor with its selective amine and recycle, closes the recovery, and the flare stack takes the upsets. The SRU purchase should draw its battery limit around acid gas in, product sulfur out, and tail gas handled, with the amine interface and utility envelopes explicit.
Utilities and plot close the configuration. The train needs boiler feed water for its waste heat boiler and condensers making steam, instrument air, nitrogen, steam for tracing and jets, fuel gas for reheats and incineration, and a plot that respects hydrogen sulfide dispersion; the sulfur pit, degassing, and loading occupy their own hazardous area with drainage and vapor control. Winterization of every sulfur line is a design absolute, not a climate option, because one frozen sulfur drain is a plant outage by definition. The buyer who specifies utilities and plot as an afterthought buys them twice.
Chapter 4 / 06
Key Specification Parameters
The licensor data sheet is organized around feed, recovery, and hardware. Feed parameters are acid gas flow and composition, hydrogen sulfide, carbon dioxide, water, hydrocarbons, ammonia, carbonyl sulfide, with contaminants stated explicitly, plus turndown range. Recovery parameters are guaranteed sulfur recovery percent at the stated feed, tail gas composition leaving, and sulfur dioxide mass rate at the stack. Hardware parameters are furnace temperature and residence, stage count, catalyst volume per stage, condenser duties and steam generation, reheat method per stage, sulfur pit capacity, and degassing method. A quotation that quotes recovery without the feed analysis it assumes is not comparable to one that states them.
Parameter
Typical range
Design note
Acid gas H2S content
20-100%
Lean feeds need split flow variants
Furnace temperature
950-1400 C
Ammonia destruction wants the top
Catalytic stages
2-4, three standard
Diminishing returns per stage
Converter temperatures
320 down to 200 C
Equilibrium pushes cooler
Recovery, straight Claus
94-97.5%
Three stage basis
Recovery with TGTU
99.5-99.9%+
Hydrogenation plus amine
Turndown
30-100% typical
Enrichment extends low end
Sulfur product
degassed liquid or solid
H2S in product spec governs
Air ratio control
H2S to SO2 at 2 to 1
Tail gas analyzer trimmed
Recovery guarantee and contaminants deserve explicit numbers in every specification because they are the contract. The licensor should state recovery at the stated analysis, including the contaminant load it was sized for, and the degradation or turndown behavior when hydrocarbon or ammonia exceed it; the buyer should state the acid gas analysis with its real variation, the permit's sulfur dioxide mass limit, and any future sour gas expansion the train must carry. Recovery quoted on a pure H2S and CO2 feed is a laboratory number, and the plant will run on the real one.
Standards ride the pressure parts, the burner, and above all the safety design. Furnace, waste heat boiler, and condensers build to fired equipment and pressure vessel codes with the sulfur service materials, 300 series stainless in wet sulfur dioxide zones, carbon steel where dry; burner management with flame safeguard and double block on fuel follows combustion safety practice; relief valves across the train ride the blocked outlet and fire cases on the sulfur system's freezing reality; and the toxic area design, ventilation, detection, and escape, follows the site's hydrogen sulfide safety philosophy without compromise. Emissions permitting governs the incinerator stack and its continuous monitoring. None of these are exotic; the safety scope is the one that must never be value engineered.
Chapter 5 / 06
Selection Decision Factors and RFQ Language
Selection starts from the acid gas and the permit, written as analyses and mass limits. The designer writes the acid gas flow and full composition with contaminant ranges, the sour water stripper gas if it joins, the required recovery percent and the sulfur dioxide mass limit behind it, the sulfur product form the market wants, and the utility and plot context. From that basis, stage count, tail gas route, and enrichment follow with little freedom. An RFQ with a sulfur tonnage alone invites a licensor to assume the cleanest acid gas in its file, and the ammonia and aromatics will be discovered at startup.
Duty driver
Favored configuration
Watch item
Gas plant, tight permit
three stage plus TGTU
Amine recycle integration
Refinery with NH3 gas
hot furnace, residence
Ammonia salt fouling control
Rich acid gas, big range
oxygen enriched
Turndown at low load
Lean acid gas
split flow or direct oxidation
Flame stability at low H2S
Remote small field
liquid redox alternative
Below Claus economic band
Tail gas route selection is the second decision and it is the permit's arithmetic. Straight Claus with incineration meets recovery to roughly 96 percent class; hydrogenation with selective amine recycle buys above 99.5 percent and dominates large plants; sub dew point and direct oxidation variants fill specific niches and retrofits. The decision prices the recovery gap against the tail gas unit's capital, its amine and utility consumption, and the permit's headroom at worst case feed, and it belongs in the RFQ as a required recovery class rather than a technology name, letting licensors propose the route they can guarantee.
The RFQ language that returns comparable offers states the feed and the guarantees demanded. State acid gas flow and full analysis with contaminant ranges, any joined stripper gas, required recovery percent with the sulfur dioxide mass limit and its basis, turndown range, sulfur product specification and form, utility envelope including steam and oxygen if considered, safety and emissions scope, and the performance test basis including contaminant challenge. A complete RFQ paragraph reads: acid gas 32 tonnes per day sulfur at 85 percent H2S, CO2 12, water 5, hydrocarbons below 1 percent, ammonia below 0.2, guaranteed recovery 99.8 percent with TGTU, sulfur dioxide below 40 kilograms per hour at stack, liquid sulfur degassed below 10 ppm H2S, turndown 30 to 100 percent, performance tested over 7 days continuous.
Commercial comparison is only fair on a normalized basis. Offers should be forced onto one table: recovery guarantee at the stated analysis with degradation basis, stage count and catalyst volumes, tail gas route and its utilities, sulfur handling scope including degassing, materials in wet sulfur dioxide service, burner and safety scope, emissions monitoring scope, delivery, and the licensor references on comparable feeds. The cheapest train is very often the one quoted on a cleaner feed than the plant will ever see, and its first contaminant excursion pays the difference in catalyst and downtime.
Lifecycle questions close the selection. What catalyst life and changeout cost at the stated contaminant load; how the plant behaves at minimum turndown and during feed losses, the classic carbon laydown events; what spares belong in day one inventory, thermocouples, burner parts, jet and steam tracing hardware; and how the recovery guarantee is tested and corrected. An SRU is bought for the life of the sour field behind it, and these questions are the difference between a licensed process and a licensed headache.
The steam and compression systems around the train deserve their own data sheet lines because they carry the plant's energy and its recycle. The waste heat recovery on the furnace and the condensers generates low pressure steam, and where the site's balance warrants it, a steam drum closes the circuit and a superheater conditions the steam for its consumer; on large trains the pressure profile is a design deliverable, not an inherited detail. Tail gas from the incineration route or the hydrogenation recycle moves through compression, a centrifugal compressor class machine on larger plants, whose reliability is the recovery guarantee's quiet dependency. Metering closes the engineering: each acid gas, air, and fuel line carries a flow meter, because the two to one ratio control and the performance test both stand on those instruments. The licensor's battery limit should be drawn to include or explicitly exclude these systems, and the buyer who lets that line blur will redraw it during commissioning at change order prices.
Chapter 6 / 06
Installation, Standards, Failure Modes, and Maintenance
Installation is a fired equipment and exchanger erection with a toxic service discipline. The furnace and its refractory dryout, waste heat boiler and condenser setting with steam system commissioning, converter catalyst loading, sulfur pit and jacketed piping fit out with tracing proved, and the analyzer and detection systems calibrated, precede a controlled startup: the furnace lights on fuel gas, acid gas introduces on a ramp with the air ratio in manual until analyzers take control, and the train pulls to full load with condensate and sulfur flows proved to the pit. The startup record, temperatures, ratios, and recoveries, is the plant's baseline for its operating life.
Failure modes have a known hierarchy. Air ratio excursion, from analyzer failure or operator trim error, suppresses recovery and pushes sulfur dioxide or hydrogen sulfide out of range, the daily discipline item; catalyst deactivation by sulfation, carbon, or water condensation, the slow capacity loss watched in converter pressure drop and conversion; ammonia salt fouling when furnace destruction fails, plugging condensers and downstream with ammonium salts; sulfur freezes in any inadequately traced line or valve, the classic availability outage; refractory and burner wear in the furnace, a turnaround item; and tail gas unit upsets, amine contamination or hydrogenation catalyst loss, dropping overall recovery. Nearly all announce themselves in tail gas analysis, converter temperatures, and pressure drops.
Symptom
Likely cause
First response
Recovery falling
ratio drift or catalyst
Analyzer check, catalyst survey
H2S in tail gas high
air too low
Trim air on analyzer, audit burner
SO2 in tail gas high
air too high
Trim air, converter temps check
Condenser dP rising
salt or sulfur fouling
Furnace NH3 audit, wash planning
Sulfur line frozen
tracing failure
Thaw procedure, tracing repair
Maintenance is planned around catalyst, tracing, and the pit. Catalyst replaced on activity trend at multi year intervals, converter internals inspected at turnarounds; steam tracing and jacketed valves walked and proved every cold season, because a single failed tracing circuit is an outage waiting; burners, refractory, and waste heat boiler on the fired equipment turnaround cycle; and the sulfur pit degassed, inspected, and its pumps maintained on a hazardous entry program. Analyzer maintenance, the air ratio control's foundation, is a monthly discipline, and its spares sit in inventory, not in a catalog.
Operational stewardship is what the purchase actually bought. Operators who hold the 2 to 1 ratio through feed swings, who respect converter temperature windows, who keep tracing healthy before winter, and who treat the hydrogen sulfide neighborhood with the seriousness it demands, run SRUs to their guarantees between planned turnarounds; operators who ride the analyzer failure or the lazy air trim pay in catalyst, permit, and eventually in the worst way. The trend board, ratio, converter temperatures, tail gas analysis, and recovery computed daily, is the plant's real contract, and reading it is the job.
FAQ
What does a sulfur recovery unit do?
It converts the hydrogen sulfide in acid gas, the stream stripped out of raw gas or refinery gas by the amine unit, into elemental sulfur. In the Claus process, a third of the hydrogen sulfide burns to sulfur dioxide in a reaction furnace, then the remaining hydrogen sulfide reacts with that sulfur dioxide over alumina catalyst in successive converters, condensing liquid sulfur between stages. Recovery runs 94 to 97.5 percent for a three stage train and above 99.5 percent with tail gas treating.
What is the Claus reaction?
It is 2 H2S plus SO2 yielding 3 S and 2 H2O: after the furnace burns exactly a third of the hydrogen sulfide to sulfur dioxide, the two species react over catalyst to form elemental sulfur and water. The reaction is equilibrium limited and exothermic, so each catalytic stage runs cooler than the last, 320 down to about 200 degrees C, to push the equilibrium toward sulfur, with a condenser after each stage removing liquid sulfur so the next stage sees clean gas.
Why does the H2S to SO2 ratio need to be 2 to 1?
Because that is the Claus reaction's stoichiometry: any surplus of either species passes through unreacted to the tail gas, so airflow to the furnace is trimmed continuously on tail gas analysis to hold the exact ratio. Too much air leaves excess sulfur dioxide, too little leaves hydrogen sulfide breakthrough, and both cost recovery and product quality. The air ratio control loop, analyzer through furnace air, is the plant's most important daily instrument.
What does a tail gas treating unit add?
It finishes the recovery job. The tail gas is hydrogenated over cobalt molybdenum catalyst, converting every sulfur species back to hydrogen sulfide, and a selective amine then recovers that hydrogen sulfide and recycles it to the Claus furnace, pushing overall recovery above 99.5 to 99.9 percent. Without it, the tail gas is incinerated and the unrecovered sulfur leaves as sulfur dioxide at the stack. Whether a plant needs a TGTU is purely its sulfur dioxide permit's arithmetic.
How is liquid sulfur handled and degassed?
Liquid sulfur drains from the condensers at 130 to 160 degrees C through fully steam jacketed lines and valves, sulfur freezes at 119 degrees C, into the heated sulfur pit or tank, where dissolved hydrogen sulfide is stripped out, by air or catalyst assisted degassing, to meet product safety specifications before pumping to storage or loading. Degassed sulfur below roughly 10 ppm dissolved H2S is the market standard. The jacketing and tracing discipline is as decisive for availability as the process itself.
Can a sulfur recovery unit destroy ammonia?
Yes, in its reaction furnace, and it must when sour water stripper gas joins the acid gas: furnace temperature and residence time are designed to crack ammonia completely, typically wanting the hot end of the 950 to 1400 degrees C band with sufficient residence. Ammonia that survives the furnace salts out as ammonium compounds in condensers and downstream equipment, fouling the train, so ammonia destruction is a furnace design guarantee, not an operating wish.
What sulfur recovery efficiency can be guaranteed?
A three stage Claus train guarantees roughly 94 to 97.5 percent depending on feed and configuration; adding a tail gas treating unit with hydrogenation and amine recycle lifts the guaranteed total above 99.5 and commonly to 99.8 or 99.9 percent. The guarantee must be quoted against the actual acid gas analysis with contaminants, because hydrocarbons, ammonia, and water all degrade the number, and the permit's sulfur dioxide mass limit is what the guarantee must clear at worst case.