Amine Unit

An amine unit is the complete acid gas sweetening plant that removes hydrogen sulfide and carbon dioxide from natural gas or process gas using a circulating aqueous amine solvent. Its anatomy is one loop: a tall absorber, or contactor, where lean amine meets raw gas at pressure and the acid gases absorb; a rich amine letdown through a flash tank where hydrocarbons and dissolved gases release; a regenerator, the still column and its reboiler, where stripping steam boils the acid gases back out of the solvent; and the exchangers, pumps, coolers, and filtration that carry the solvent between them. BASF's OASE family and Shell's ADIP and Sulfinol lines are the reference solvent portfolios, and the US EPA's AP-42 Section 5.3 documents the process's emissions profile for natural gas processing.

This page is written for the engineer specifying gas sweetening capacity, whether for a pipeline specification, a feed to downstream liquefaction or synthesis, or an emissions obligation. It works through how the absorber and regenerator loop functions, which solvents and column designs fit which removal duties, the parameters on vendor data sheets, and the selection factors and RFQ language that decide whether the installed unit meets its treated gas specification at its promised energy and amine consumption.

Vertical vessel hardware of the gas processing plant class that amine contactors and regenerators belong to

Photo: Didier Duforest, CC0, via Wikimedia Commons

The decision concentrates in five places: the feed gas and its acid gas load, the treated specification that must be met, the solvent class the duty selects, the heat and utilities the site supplies, and the materials and filtration that keep the loop healthy. Get those right and the column sizes, circulation, and reboiler duty follow.

Chapter 1 / 06

What an Amine Unit Is and What Is Being Decided

The industrial plant this page describes is a solvent loop with two towers. The absorber is a tall pressure vessel, trayed or packed, where raw gas enters near the bottom and lean amine descends from the top: at the contactor's pressure and temperature the acid gases, hydrogen sulfide and carbon dioxide, dissolve into and react with the amine solution, and sweet gas leaves the top while rich amine leaves the bottom. The regenerator is its mirror at low pressure: the rich solvent, heated through the lean rich exchanger, descends the still column against rising steam generated in the reboiler, the acid gases strip out, and lean amine returns to service. Between the towers, the flash tank releases hydrocarbons picked up at pressure, filters clean the circulating solvent, and a cooler trims the lean amine to absorption temperature.

What is being decided when an amine unit is purchased is a treated gas specification at a feed rate, delivered at an energy and solvent consumption. The buyer is purchasing an outlet hydrogen sulfide and carbon dioxide, commonly to pipeline's quarter grain or to liquefaction's parts per million levels, at the stated flow, pressure, and inlet composition, with a stated reboiler duty per unit of acid gas removed, a stated amine make up rate, and a stated availability between turnarounds. Everything on the vendor data sheet, absorber stages, circulation rate, regenerator pressure and duty, solvent concentration, exists to support those numbers, and the five decisions this page works through determine whether the unit holds its specification through its feed's swings.

The amine unit occupies a precise place in the gas conditioning landscape and its boundaries matter. It is not a glycol dehydrator: that unit circulates triethylene glycol to remove water and meet a dew point specification, and this site's glycol dehydrator page covers it; the two loops look like siblings, tall contactor and still, and do entirely different chemistry, one absorbing acid gases, the other desiccating water. It is not a molecular sieve dehydrator, the solid adsorbent route to deep water removal, which sometimes follows this unit in treating trains. It is not any single column or hardware class: the packed tower and the reboiler are components of this plant, each with its own page, but the amine unit is the loop that contains them, and the purchase is the integrated system, not a vessel.

Different buyers buy the same plant for different reasons. A gas plant operator buys sweetening to meet the pipeline's hydrogen sulfide specification before sales. An LNG facility buys deep acid gas removal to protect the cryogenic train from carbon dioxide freezing, often with special solvents to parts per million. A refinery buys amine treaters to sweeten fuel gas, LPG, and tail gas from the sulfur plant. A geothermal or biogas operator buys smaller units to clean process streams of hydrogen sulfide and carbon dioxide. An ammonia or synthesis gas plant removes carbon dioxide to protect catalysts. The specification language differs, but the loop physics is shared, and the paragraphs that follow keep all of these buyers in view.

A short tour of named duties makes the plant concrete. At a gas plant, a 20 bar feed with two percent carbon dioxide and fifty parts per million of hydrogen sulfide sweetens to pipeline spec in a 20 tray absorber with MDEA, the flash gas routes to fuel, and the acid gas from the still overhead goes to sulfur recovery or the flare stack. At an LNG pretreatment, an activated solvent takes carbon dioxide to below two parts per million ahead of the molecular sieve dehydration and the cold box. At a refinery, fuel gas amine runs at higher concentration with formulators that fight the trace contaminants refining streams carry. In each duty the same five knobs appear: feed, spec, solvent, utilities, materials.

The purchase is never the towers alone, and the RFQ that forgets the loop's health systems buys a corrosion and foaming problem with columns attached. The filters, full flow particulate and carbon side streams, that clean the solvent; the reclaiming or purge arrangement that manages heat stable salt accumulation; the materials class that survives rich amine and acid gas service; and the analyzer package, treated gas hydrogen sulfide monitoring, lean and rich loading samples, that tells the operators what the loop is doing, are as much the product as the steel. A sweetening unit is a chemical plant wearing a gas plant's clothes, and it is bought as one.

Chapter 2 / 06

How the Absorber and Regenerator Loop Does the Work

The absorption chemistry is reversible reaction, and the loop is its engine. Primary and secondary amines, MEA and DEA in the classical names, react directly with carbon dioxide to form carbamates, fast and stoichiometric, two amine molecules per carbon dioxide; tertiary amines, MDEA, cannot form carbamates and instead promote carbon dioxide's hydrolysis to bicarbonate, slower, one amine per acid gas equivalent, and largely untouched by hydrogen sulfide's instant proton transfer. The difference is the selectivity lever: MDEA absorbs hydrogen sulfide quickly and carbon dioxide slowly, so with the right contact time it takes the hydrogen sulfide and passes much of the carbon dioxide, the selective duty pipelines and tail gas plants buy.

Loading and circulation are the loop's mass balance. Rich loading, moles of acid gas per mole of amine leaving the absorber, runs typically 0.2 to 0.6 by solvent and duty against an equilibrium ceiling near 0.7 to 0.8 for CO2 on MDEA and lower for carbamate formers; lean loading, what the regenerator delivers back, decides how deep the absorber can reach, bulk removal tolerates lean loadings near 0.01, deep specifications demand below 0.005 and pay for the steam to get there. Circulation follows: solvent flow equals acid gas to be removed divided by the working loading span, times the amine concentration, typically 20 to 50 weight percent aqueous, and the circulation rate is the number that sizes pumps, exchangers, and the regenerator's hydraulics more than any other.

The regenerator closes the loop with steam. In the still column, hot rich amine descends against stripping vapor: the reboiler boils water from the solvent at the still's pressure, typically 1 to 2 bar absolute, and that steam, climbing the column's trays or packing, carries the acid gases out of solution and overhead to the condenser, where reflux returns and the acid gas, now concentrated, leaves for sulfur recovery, incineration, or the flare. Reboiler duty is the unit's energy bill, classically quoted around 0.9 to 1.2 kilograms of steam per kilogram of acid gas in bulk service and higher for deep lean, and the duty's quality, low pressure steam, hot oil, or direct fired, follows the site's utility balance.

Flash and filtration are the loop's sanitation. The rich amine letdown passes the flash tank first, where dissolved hydrocarbons and some acid gas release at intermediate pressure: the flash gas is recovered as fuel where its composition allows, and skipping the flash costs the regenerator its hydrocarbon carryover, the acid gas diluted and the still's foaming fed. Downstream of the flash, mechanical filters take particulates and iron sulfide, a slipstream carbon filter adsorbs the surfactant contamination that causes foaming, and the solvent keeps the cleanliness that the towers' hydraulics assume. On units that run hard, an amine reclaimer, distillative or ion exchange, purges the heat stable salts that accumulate from gas contaminants and degrade the solvent's capacity.

Corrosion is the loop's tax and the materials class is its management. Rich amine carrying acid gas is corrosive, hot rich amine carrying carbon dioxide aggressively so, and the classic damage locations are the hot lean rich exchanger's rich side, the reboiler and still bottoms, and any high velocity rich line; the design answers are velocity limits, corrosion allowances, stainless upgrades at the hot spots, and the oxygen exclusion that keeps amine from forming corrosive degradation products. Heat stable salts, formates and acetates and thiosulfates from gas contaminants and oxygen ingress, both consume solvent capacity and accelerate corrosion, and their measurement and purge or reclamation is a routine operating number, not a troubleshooting event.

Control and analysis are the loop's nervous system. The absorber's temperature profile walks the reaction front and tells the operators whether the solvent is lean enough and the circulation matched to the feed; the treated gas analyzer, hydrogen sulfide or carbon dioxide by the specification that matters, is the compliance instrument; and the lean and rich loading samples, with the heat stable salt analysis, are the chemistry lab's calendar. A level transmitter on every drum, pressure control at the still, temperature control at the reboiler, and the interlocks that protect the towers and the flare make up the panel, and a modern unit reports all of it to the control room continuously.

Chapter 3 / 06

Solvent Classes, Column Types, and Duty Boundaries

The solvent is the first type decision and the contaminant list makes it. MEA, the primary workhorse of history, reacts fast with everything, suits total removal at low pressure and high carbon dioxide, and pays in high energy and corrosion; DEA, the secondary, is the moderate generalist that still runs thousands of units. MDEA, the tertiary, is the modern base: selective for hydrogen sulfide over carbon dioxide, lower energy, less corrosive, and the platform for the formulated class. Formulated solvents add promoters and chemistry packages to that base: BASF's OASE family spans the duties, the purple line for total natural gas treatment and the yellow line for selective treatment, and Shell's ADIP and Sulfinol lines include the hybrid solvent that carries a physical component for high acid gas partial pressures.

Hybrid physical chemical solvents own the high loading end. Where the acid gas partial pressure runs high, deep gas fields and synthesis gas, a physical solvent, sulfolane in the Sulfinol class or other organic carriers, dissolves acid gases without reaction, doubling or tripling the circulation capacity per barrel, cutting regenerator energy, and co absorbing mercaptans and organic sulfur that aqueous amines pass; the price is heavier hydrocarbon co absorption and a different operating envelope. Aqueous formulated amines keep the mechanical simplicity of the water loop where the partial pressures are moderate, and the solvent choice is an engineering economics study, feed composition against utility costs, that the licensor runs with the buyer's gas analysis in hand.

Solvent classCharacterTypical dutyWhere it wins
MEA, primaryfast, total, corrosivedeep total removal, low pressureHistorical depth at energy cost
DEA, secondarygeneral purposerefinery and gas plant bulk dutyTolerance to contaminants, familiarity
MDEA, tertiaryselective H2S over CO2pipeline spec, tail gas treatSelectivity, low energy, low corrosion
Formulated or activatedpromoted MDEA packagesdeep CO2 to ppm, LNG feedDeep spec at managed energy
Hybrid physical chemicalamine plus physical solventhigh acid gas partial pressureCapacity per barrel, mercaptans

Column internals are the second type decision. Trayed absorbers, the classic twenty or more valve or bubble cap trays, tolerate fouling and fouling iron sulfide service and hold liquid for the reaction kinetics; packed columns, structured packing in modern units, shrink the towers' diameter and height for the same duty at lower pressure drop, and own the revamp market where capacity must grow inside existing shells. The regenerator mirror runs the same choice with the steam hydraulics driving it. Skid modular units serve the small and remote end, and the sized engineered plant the large; between them the choice is capital and logistics, not chemistry.

Duty boundaries against the neighbors deserve plain language. When the problem is water, the machine is the glycol dehydrator with its TEG loop, and its page owns it; when the water spec is deep and the acid gases already gone, the molecular sieve dehydrator owns the polish. When the problem is a slug or mist in the gas, the slug catcher, the knockout drum, and the mist eliminator do that work ahead of this unit's contactor, and the coalescing filter polishes the feed further. The acid gas this unit releases goes to sulfur recovery or up a flare stack, and the treated gas's quality is confirmed by the gas analyzer and, for water, the dew point transmitter downstream. Each neighbor has its page; this one is the loop that takes the acid gases out.

Chapter 4 / 06

Key Specification Parameters

Vendor and licensor proposals revolve around a compact parameter set, and a buyer who reads them against the gas analysis can compare offers on engineering terms. The table below collects the parameters that decide performance for mainstream natural gas sweetening duty, with the ranges a reviewing engineer should expect.

ParameterTypical specification rangeWhat it decides
Feed gas rate and pressuresite specific, 5 to 100+ barContactor hydraulics and absorption driving force
Inlet acid gasH2S ppm to %, CO2 % levelsSolvent circulation and loading basis
Treated gas specH2S 4 ppm class, CO2 to 50 ppm for LNGThe compliance number and lean loading demand
Amine circulationfrom acid gas load and loading spanPumps, exchangers, regenerator sizing
Solvent concentration20 to 50 wt% aqueousCapacity per barrel, corrosion class
Rich loading design0.2 to 0.6 mol/molCirculation economy against equilibrium
Lean loading target0.005 to 0.02 mol/molDeep spec reachability, reboiler energy
Reboiler duty0.9 to 1.2+ kg steam per kg acid gasThe energy bill and utility selection
Absorber stages or bed depth10 to 30 trays equivalentApproach to spec at the circulation chosen
Materials and corrosion classCS plus SS at hot spotsLife in rich amine and acid gas service

Two of those numbers do the design work. Circulation, from the acid gas load divided by the working loading span, sets the size of everything wet: pumps, the lean rich exchanger, the cooler, and the regenerator's hydraulic identity; proposals with materially different circulations are proposing different loading assumptions, and the comparison must normalize to them. Lean loading, bought with reboiler energy, sets the treated specification's reach, and the deep specifications, the parts per million classes, are won or lost in the regenerator's steam and reflux design before the absorber ever sees the gas.

The remainder of the parameter set carries the loop's health and the site's realities. The reboiler duty and its steam quality are the operating cost core, quoted per unit of acid gas for honest comparison; the materials class and velocity limits are the corrosion insurance; the filtration and reclamation scope is the solvent's longevity plan; and the analyzer package is the compliance instrument. Utility integration, steam at the right pressure, cooling for the lean amine and the still condenser, and the acid gas's destination, sulfur plant, incinerator, or flare, complete the boundary the proposal must state to be comparable.

Chapter 5 / 06

Selection Decision Factors and RFQ Language

Gas definition comes first because the solvent inherits it. The specification should state the full composition: hydrocarbon dew point character, hydrogen sulfide and carbon dioxide exactly, plus the trace list that changes everything, carbonyl sulfide, carbon disulfide, mercaptans by species, oxygen, and any higher synthesis gas components on petrochemical feeds. Flow and pressure with their swings, and the treated specification, pipeline's hydrogen sulfide limit, liquefaction's carbon dioxide ceiling, or a sulfur plant's tail gas demand, fix the duty's depth. Feed contaminants deserve their own lines because they select the solvent class and size the filtration and reclamation scope.

Site and downstream context come second. State the heat medium available, low pressure steam, hot oil, or direct fired reboiler, because the solvent choice trades energy against circulation and the utility balance prices it; the cooling medium for the lean amine and still condenser; the acid gas disposition, sulfur recovery, acid gas reinjection, or destruction, which sets the overhead system's design; and the plot, offshore platform constraints or onshore modularity, which selects skid against engineered plant. Where the unit follows a three phase separator and feed filtration on the gas train, state what is provided so the amine unit's inlet coalescing scope is boundary clear.

Selection factorWhat to specifyCommon mistake
Gas analysisH2S, CO2, COS, CS2, mercaptans, O2Solvent chosen on H2S and CO2 only
Treated specificationoutlet ppm basis by componentBulk spec quoted for a deep LNG duty
Solvent class basisselective or total, formulated or hybridGeneric MDEA promised for a deep spec
Utilitiessteam or hot oil, cooling mediumReboiler duty priced without a heat source
Acid gas dispositionsulfur plant, reinjection, flareOverhead system designed after the fact
Materials and healthcorrosion class, filtration, reclamationLoop health systems value engineered out
Analyzer scopetreated gas and loading instrumentsCompliance discovered by pipeline quality shake

RFQ language that produces comparable offers follows from those factors and should read like a gas plant basis document. State the gas analysis and specification, the flow and pressure envelope, the utilities, the acid gas disposition, and the plot constraints. Ask every licensor to state the solvent and its rationale against the contaminant list, the circulation and loading basis, absorber and regenerator dimensions with internals type, the reboiler duty and its heat medium basis, lean loading guarantee, amine make up expectation, the filtration and reclamation package, the materials map at the corrosion hot spots, and the reference units on comparable gas, because this is a licensed experience product as much as a steel one.

Guarantees and acceptance close the procurement. A defensible offer guarantees the treated gas composition at the stated feed conditions, the reboiler duty and amine consumption within stated bands, and the unit's capacity and turndown envelope, demonstrated at performance test with the gas analysis and instrument plan the contract names. Hold every bidder to the same gas basis, weight offers on energy and solvent consumption per unit treated over capital, and include the operator training and solvent support program in the scope, because the loop's first year of operation decides whether the guarantees were ever more than paper.

The balance of plant the RFQ must not forget: the lean rich shell and tube heat exchanger and its sparing, the amine pumps with their seals suited to the solvent class, the aerial or water coolers on the lean and overhead streams, the flash tank and its gas recovery, the filters with their piping as a slipstream that runs always, the reboiler with its heat source integration, and the analyzer house with the treated gas instrument. A knockout drum and mist eliminator on the feed and a coalescing filter ahead of the contactor protect the solvent from liquids the upstream separation may pass, and the flare stack or acid gas tie in closes the loop's outlet.

Chapter 6 / 06

Installation, Standards, Failure Modes, and Maintenance

Installation is a chemical plant erection. The towers lift, the loop's exchangers, pumps, and drums set on the plot, the utility and acid gas ties connect, and the system cleans, water washes, and charges with solvent before gas introduces itself. Commissioning brings the solvent to its chemistry: circulation established, the regenerator on line, the absorber pressurized, and the feed raised in steps while the treated gas analyzer walks the specification into guarantee, with the first lean and rich loading samples calibrating the lab against the panel.

Standards shape the unit through several regimes. The EPA's AP-42 Section 5.3 documents natural gas processing emissions, the framework the unit's air permitting works from with its estimates for amine units' VOC and hazardous air component releases; pressure vessel and piping codes govern all the steel; process safety management applies wherever the acid gas and flammable streams set the hazards; and the solvent suppliers' handling and waste regimes govern the amine itself. A buyer names the applicable regimes and expects the licensor's compliance map, because an amine unit that surprises its permit at start-up has surprised its community too.

Failure modeSignatureResponse
Foaming in absorber or stilllevel instability, carryover, capacity lossAntifoam, carbon filter slipstream, contamination source hunt
High treated H2S or CO2spec excursion at analyzerCirculation and lean loading check, regenerator duty, stages audit
Corrosion and iron sulfide foulingfilter loading, wall loss surveysVelocity limits, materials upgrade, HSS purge discipline
Heat stable salt accumulationrising amine losses, capacity fadeReclaimer operation, solvent purge and make up program
Amine losses to gas or acid streammake up rate climbingSeparator and water wash on overhead, mist elimination review
Reboiler fouling or tube lossduty drift, hot spot indicationsService, salt management, heat flux review

Routine operation is chemistry led. The daily panel reads circulation, temperatures, and pressures against the loading numbers the lab returns weekly; the filters' differential pressure schedules their service; the amine strength and heat stable salt analyses set the make up and reclamation calendar; and the treated gas analyzer is the number the whole plant answers to. Turnaround work concentrates in the towers' internals inspection, the reboiler and exchangers' service, and the corrosion survey program whose history tells the plant where its next materials dollar goes.

Operator capability and solvent support close the ownership picture. A sweetening loop is run as much by its lab and its trends as by its panel, so the commissioning program trains the crew on the loading math, the foaming response, and the salt management calendar, and the solvent supplier's technical service stays in the loop on analyses and make up for the unit's life. Spares follow the failure modes: filter elements in the right micron and chemistry for continuous slipstream duty, seal kits for the amine pumps' seals, analyzer consumables, and the antifoam and reclaiming consumables whose absence turns a managed chemistry into a quarterly crisis.

The mechanical inventory deserves its own line because the loop is a pump and instrument plant as much as a chemistry plant. The amine pumps themselves, a progressive cavity pump on rich service where the gas entrainment must not choke the machine and a centrifugal pump on lean duty at the circulation the design set, carry seals suited to the solvent; a flow meter on the circulation line and on the rich letdown closes the loop's mass balance; and the panel's pressure transmitters and level switches across the flash tank, filters, and still bottoms give the control system the state it sequences on. None of it is exotic, and all of it is the difference between a loop that runs and a loop that is nursed.

The end state of a well specified amine unit is a gas sales line that never thinks about sulfur. The feed's acid gases enter the loop and leave as a concentrated acid gas stream the sulfur plant or the flare disposes of, the treated gas holds its specification through feed swings because the circulation and regenerator were designed with margin, the solvent ages on a managed curve because the filtration and reclamation were bought, not value engineered, and the energy bill per kilogram of sulfur removed is the number the plant quotes against.

FAQ

What does an amine unit actually do?

It circulates an aqueous amine solvent between two towers to remove acid gases from a gas stream. The absorber contacts lean amine with raw gas at pressure, the hydrogen sulfide and carbon dioxide absorb and react into the solvent, and sweet gas leaves the top; the regenerator strips those acid gases back out with reboiler steam and returns lean amine to service. The concentrated acid gas overhead goes to sulfur recovery, reinjection, or destruction.

Which solvent should my unit use?

The contaminant list and the treated specification decide. MEA and DEA suit total removal with the older chemistries' energy and corrosion costs; MDEA is the modern base, selective for hydrogen sulfide over carbon dioxide, energy light, and the platform for formulated packages; activated or promoted formulations reach deep carbon dioxide specifications for LNG and synthesis feeds; hybrid physical chemical solvents win at high acid gas partial pressures and on mercaptan rich gases. The licensor's study with your gas analysis is the honest selection method.

Can the unit remove H2S while keeping CO2 in the gas?

Yes, that is MDEA's selectivity. Hydrogen sulfide protonates instantly on contact while carbon dioxide's reaction through bicarbonate is kinetically slow, so a short contact time absorber takes the hydrogen sulfide and passes a large share of the carbon dioxide. Pipelines that only have an H2S specification, and tail gas units that want the CO2 to stay with the gas, buy exactly this duty, and the contact time and circulation are tuned to the split.

Why do amine units foam, and what can be done?

Foaming comes from surface active contamination, condensed hydrocarbons, compressor oils, upstream chemicals, and degradation products, meeting the solvent and turning the towers' hydraulics unstable. The engineering answers are upstream: feed cleaning with a knockout drum and coalescing filtration, clean amine make up, oxygen exclusion. The operating answers are a carbon filter slipstream that adsorbs surfactants continuously and antifoam as a controlled response, not a diet.

Where does the amine go, and what are normal losses?

Losses go three ways: vapor carryover with the treated gas, entrainment and evaporation with the acid gas overhead, and chemical degradation into heat stable salts that consume solvent capacity. A healthy unit's make up is measured in kilograms per day and dominated by degradation, managed by filtration, oxygen exclusion, and reclamation of the salts. A climbing make up rate is the plant's earliest sign of contamination or salt accumulation.

What is the acid gas outlet used for?

It is a concentrated hydrogen sulfide and carbon dioxide stream at near atmospheric pressure. Where sulfur recovery exists, it feeds the Claus plant and becomes elemental sulfur; where acid gas reinjection exists, it compresses back into a reservoir; and otherwise it is destroyed by incineration or the flare stack. The disposition choice is set at design time and configures the unit's overhead system and the site's emissions profile.

How is an amine unit different from a glycol dehydrator?

They are loop siblings doing different chemistry. The amine unit absorbs and reacts out acid gases, hydrogen sulfide and carbon dioxide, with an aqueous amine; the glycol unit absorbs water with triethylene glycol to meet a moisture dew point. A gas with both problems runs both units in series, sweetening first, dehydration after, and sometimes a molecular sieve for the deepest water specifications.

Sources

  1. BASF: OASE purple for natural gas treatment
  2. BASF: OASE yellow for selective treatment
  3. Shell Catalysts and Technologies: Switching to ADIP-X or Sulfinol-X
  4. US EPA: AP-42 Section 5.3, Natural gas processing (PDF)
Ask SpecForge AI