A steam methane reformer is a fired process plant that reacts steam with methane, most often natural gas, over nickel catalyst inside high alloy tubes suspended in a furnace box, producing hydrogen mixed with carbon monoxide, carbon dioxide, and unreacted methane at tube outlet temperatures near 800 to 900 degrees C. Around that furnace a complete plant wraps feed desulfurization, a waste heat boiler and steam system, shift converters that convert carbon monoxide to more hydrogen, and a purification train, most commonly pressure swing adsorption, that delivers hydrogen at purities above 99.9 percent. The US Department of Energy catalogs natural gas reforming as the dominant hydrogen production route today, and licensors such as Topsoe supply the reformer technology at the heart of these plants, from small packaged units below 500 cubic meters per hour to world scale trains above 100000 normal cubic meters per hour.
This page is written for the engineer specifying a steam methane reformer plant for refinery hydrogen, ammonia or methanol synthesis gas, or merchant hydrogen duty. It works through what the reformer furnace actually does and what is being bought, how steam to carbon ratio, tube outlet temperature, and heat flux govern the design, which reformer configurations and purification chains fit which capacities, the parameters that appear on licensor data sheets, and the selection factors and RFQ language that decide whether the plant hits its hydrogen rate, purity, and reliability targets.
The decision concentrates in five places: the feedstock and its sulfur and hydrocarbon character, the reformer configuration whose duty range matches the capacity, the steam to carbon ratio and tube outlet temperature that set conversion and tube life, the shift and purification chain that meets the hydrogen purity, and the steam balance that turns waste heat into export value or a parasitic load. Get those right and the tube count, burner duty, and vessel sizes follow.
Chapter 1 / 06
What a Steam Methane Reformer Is and What Is Being Decided
The machine this page describes is a complete reforming plant whose heart is the fired furnace and its catalyst tube bank. Tubes of centrifugally cast high nickel alloy, typically 10 to 13 centimeters in diameter and 10 to 14 meters long, are packed with nickel based reforming catalyst and hang or stand inside a refractory lined furnace box fired by side wall or terrace burners, or by roof burners in some layouts. Hydrocarbon feed that has been desulfurized and mixed with superheated steam flows through the tubes, and the products leave as a syngas at near 900 degrees C into a transfer line headed for heat recovery and shift conversion. Everything else in the plant exists to feed the tubes correctly and to work the product stream up to specification.
What is being decided when a steam methane reformer is purchased is a hydrogen or syngas production guarantee backed by a tube life and an efficiency statement. The buyer is purchasing a stated hydrogen rate at a stated purity, commonly above 99.9 percent after pressure swing adsorption or at synthesis gas ratios for ammonia or methanol service, at a stated feed and fuel consumption and with reforming tubes whose life, commonly 10 years plus in well run plants, is the single largest maintenance exposure. Everything on the licensor data sheet, duty, tube outlet temperature, flux, steam to carbon ratio, pressure, export steam, exists to support those guarantees, and a serious inquiry forces each number onto the table with its basis.
The steam methane reformer sits in a hydrogen technology landscape with defined neighbors and boundaries. It is not a hydrogen electrolyzer, which splits water electrically and suits small footprint and renewable power contexts, while the reformer is the incumbent for large scale, low cost hydrogen from natural gas with the associated carbon dioxide burden. It is not a fired heater, the process furnace duty that raises stream temperatures without catalytic reaction, although reformer furnaces share burner and radiant box engineering. It is not autothermal reforming, which supplies reforming heat by partial oxidation inside a refractory lined vessel rather than by external firing, and it is not the waste heat recovery duty covered by a heat recovery steam generator, which this plant needs downstream of its own flue gas and syngas rather than being one.
Different buyers buy the same reformer for different products. A refinery buys hydrogen to feed hydrotreaters and hydrocrackers, valuing reliability above nearly everything because a hydrogen plant trip strands units upstream. An ammonia producer buys synthesis gas at a 3 to 1 hydrogen to nitrogen ratio, tolerating the air addition step and valuing steam integration with the synthesis loop. A methanol producer buys syngas near a 2 to 1 stoichiometric number, often combining reforming with secondary reforming to reach it. A merchant or fueling operator buys packaged small reformers where electrolysis economics or footprint lose. The specification language differs, but the tube physics and the steam balance are shared.
The economics deserve their own paragraph because fuel dominates. Roughly speaking the reformer burns natural gas both as feed and as furnace fuel, and thermal efficiency, hydrogen yield per unit of total gas, plus the credit for exported steam decide the operating cost picture more than any other choice. Carbon intensity is now part of the same paragraph: flue gas carbon dioxide is concentrated and capture ready in a way few flue gas streams are, and brownfield hydrogen plants are among the first capture retrofit targets, so plot space, flue gas ducting, and steam availability for capture reboiler duty belong in the initial layout thinking even when capture is a later phase.
A short tour of named duties makes the plant concrete. At a refinery hydrotreater complex, desulfurized natural gas plus medium pressure steam reform across a single cell box furnace, shift in two adiabatic stages, purify in a twelve bed pressure swing adsorption unit, and deliver 60000 normal cubic meters per hour of hydrogen at 24 bar to the header. At a world scale ammonia plant, a parallel fired reformer feeds a secondary autothermal stage and the purge gas heat drives a steam turbine. At a fueling station pilot, a compact reformer with a bayonet tube design makes a few hundred cubic meters per hour on a skid. Each duty names the same knobs, steam to carbon, tube outlet temperature, flux, shift depth, and purification, with numbers that scale while the chemistry barely changes.
Chapter 2 / 06
How the Reformer Does the Work
The chemistry is endothermic steam reforming over nickel: methane plus steam absorbs heat and yields carbon monoxide plus hydrogen, followed immediately by the water gas shift equilibrium, carbon monoxide plus steam yielding carbon dioxide and more hydrogen, which is fast at tube conditions and sets the carbon monoxide to carbon dioxide ratio leaving the tubes. Both reactions ride on a nickel catalyst on a calcium aluminate or magnesium aluminate support, shaped as rings or pellets to balance activity against pressure drop. Because the overall reforming reaction absorbs roughly 206 kilojoules per mole of methane, the furnace must deliver that heat through the tube wall, and that fact organizes the whole machine: burners, radiant box geometry, and tube metallurgy all exist to deliver heat flux to the catalyst without overheating the tube.
Steam to carbon ratio is the first governing variable, defined as moles of steam per mole of carbon in the feed. Operation at 2.5 to 3.5 is typical for natural gas, high enough to suppress carbon formation on the catalyst via methane cracking and via the carbon monoxide disproportionation route, and low enough not to waste heat raising steam that leaves the process unconverted. Higher ratios buy margin against coking on heavier feeds or in peak firing; lower ratios, pushed hard in modern designs toward 2.0 with advanced catalyst and tight control, improve efficiency and cut export steam but narrow the safety margin against carbon laydown, a trade the buyer should see quantified rather than asserted.
Tube outlet temperature and heat flux are the second and third governing variables. Methane conversion rises steeply with temperature, so designs push tube outlet toward 850 to 900 degrees C for hydrogen and syngas duties that want low residual methane. Design heat flux through the tube wall, historically near 70 to 85 kilowatts per square meter in classic designs and above 100 in advanced high flux boxes, sets how hard the tubes work, and together with the tube alloy creep life it sets how long tubes survive: the cast micro alloy, typically a 35 nickel 25 chromium class with niobium and micro alloy additions, creeps under internal pressure and temperature, and every excursion above design temperature spends tube life faster than the clock. Tube skin thermocouples and flux discipline are not instrumentation luxuries; they are the tube life warranty in hardware form.
Pressure pushes the equilibrium the wrong way, mildly, since reforming increases mole count, but plants operate at 20 to 40 bar anyway because downstream purification, delivery pressure, and equipment size reward it; the penalty shows up as slightly higher residual methane and higher tube duty, accepted in the design balance. Downstream of the tubes, the hot syngas must be cooled fast through a waste heat boiler, usually generating high pressure saturated steam that the process partly consumes as reforming steam in a natural recycle elegance, with the balance exported or condensed. A steam drum separates the boiler water circuit, and the plant's demineralized water treatment, in hardcore terms a chain ending in mixed bed polisher or equivalent polishing after reverse osmosis, protects the boiler from deposits, a detail that belongs in any reformer plant scope conversation.
Shift and purification finish the product. High temperature shift over iron chromium catalyst converts most carbon monoxide to carbon dioxide near 350 degrees C, and where hydrogen purity demands it, low temperature shift over copper zinc catalyst pushes conversion further near 200 degrees C, with selectivity poisoned by sulfur and chloride that the feed pretreatment must already have removed. Pressure swing adsorption then removes carbon dioxide, carbon monoxide, methane, and nitrogen in one step to deliver 99.9 percent plus hydrogen, at the cost of a purge tail gas that carries recoverable heating value back to the furnace burners. For synthesis gas duties the purification is instead ratio adjustment and carbon dioxide removal in an amine unit style wash or a physical solvent, chosen by the downstream synthesis.
Combustion side emissions close the design conversation. Burners designed for low nitrogen oxide emission, staged or flue gas recirculating classes, hold NOx within permit bands, and carbon monoxide burnout depends on residence and excess air control. The flue gas stream is the concentrated carbon dioxide source, typically 8 to 20 percent by volume after air firing, and the syngas side after shift is even more concentrated, which is why capture studies look at both streams. A flare stack handles relief and startup venting, gas detectors watch the hydrogen and natural gas boundaries, and pressure relief on the steam and gas systems rides safety relief valves, all standard process plant plumbing but each with a reformer specific sizing story.
Chapter 3 / 06
Reformer Types, Plant Configurations, and Duty Boundaries
Reformer configurations divide by how heat reaches the catalyst and by capacity fit. The classic top fired box reformer hangs tubes between two rows of terrace burners and dominates medium and large hydrogen service with proven scale beyond 200000 normal cubic meters per hour in multi cell plants. Side fired wall burner reformers surround tubes with many small wall flames, giving uniform flux profiles and a long history in ammonia and methanol service. Compact bayonet reformers, in which tubes contain an inner return tube and combustion or hot flue gas heats differently, package small capacities with quick delivery, and are offered commercially in standardized sizes for fueling and distributed hydrogen. Heat exchange reforming couples a portion of duty to hot process gas from a secondary autothermal reformer rather than to a furnace, and full autothermal reforming moves all heat inside a refractory lined vessel by partial oxidation.
Configuration
Heat source
Capacity fit
Character
Top fired box
terrace burners
medium to world scale
Highest single train rates
Side fired wall burner
many wall burners
medium to large
Uniform flux, tall tubes
Compact bayonet package
fired, compact
small, under ~2000 Nm3/h
Skid mounted, fast delivery
Heat exchange reformer
hot process gas
with ATR train
Furnace duty partially replaced
Autothermal reformer
partial oxidation
large syngas
No furnace box, O2 or enriched air
Plant configuration around the furnace follows the product. A hydrogen plant chain reads: feed filtration and compression as needed, hydrodesulfurization and zinc oxide beds to below 0.1 ppm sulfur, steam addition at the design ratio, reformer furnace, syngas waste heat boiler with steam drum, feed preheat coils in the flue gas, high and optionally low temperature shift, heat recovery to boiler feed water, and pressure swing adsorption with tail gas fired back to the furnace. An ammonia chain adds air or nitrogen to the secondary reformer and usually a methanation guard, a methanol chain adjusts the stoichiometric ratio, and both swap the purification step for synthesis gas conditioning. The fired heater appearing in some flowsheets as an auxiliary duty is a neighbor, not the reformer itself, and the split of scope between licensor package and owner balance of plant is a commercial line that must be drawn explicitly in the RFQ.
Duty boundaries keep the technology honest. The reformer wants light feeds: natural gas, refinery off gas, liquefied petroleum gas vaporized, or naphtha with the right catalyst and higher steam ratio; heavier liquids and coal belong to other technologies. Feed sulfur, chloride, and heavy metals must be removed ahead of the catalyst or the nickel deactivates, which is why desulfurization is never optional. Very small hydrogen demands below roughly 50 cubic meters per hour usually lose to delivered hydrogen or electrolysis, and very large syngas duties with cheap oxygen often favor autothermal or combined reforming economics. Within its boundaries the technology is the lowest cost large scale hydrogen route available today.
Where the reformer sits in the wider site matters as much as its internals. The export steam line connects to site steam headers and its value or disposal decides net efficiency claims; the boiler feed water chain, with polishing after reverse osmosis, or a mixed bed polisher as the final ion guard, is owner scope more often than not and a classic interface miss. The tail gas and startup fuel tie to the fuel gas header with a knockout drum against liquid carryover, relief headers run to the flare stack, and compressed hydrogen leaves through dryers to the consumer. Buyers who map these interfaces before award receive a plant; buyers who map them after startup receive change orders.
Chapter 4 / 06
Key Specification Parameters
The licensor data sheet for a reformer plant is organized around rate, severity, and utility anchors. Rate anchors are hydrogen or syngas production at reference conditions and turndown range, commonly 30 to 100 percent of design. Severity anchors are tube outlet temperature, design heat flux, operating pressure, and steam to carbon ratio, together with expected approach to equilibrium and residual methane. Utility anchors are total feed plus fuel consumption per unit hydrogen, export steam quantity and pressure, boiler feed water demand, and electrical load. Mechanical anchors are tube size and count, alloy grade, burner type and NOx guarantee, and PSA bed count and cycle. A quote that hides flux or steam to carbon basis behind a single efficiency number is not comparable to one that states them.
Parameter
Typical range
Design note
Hydrogen capacity, single train
500-100000+ Nm3/h
Configuration follows capacity
Tube outlet temperature
800-900 C
Higher is more conversion, less tube life
Design heat flux
70-100+ kW/m2
Creep driver on tube wall
Operating pressure
20-40 bar
Trade vs residual methane
Steam to carbon ratio
2.0-3.5
Coking margin vs efficiency
Tube alloy
cast 35Ni25Cr class
Creep limited life, 10 yr target
PSA hydrogen purity
99.9%+
Tail gas returns to burners
Flue gas NOx
per burner guarantee
Low NOx burner class
Export steam
HP or MP saturated
Positive or parasitic by site
Tube life deserves numbers in the specification because it is the dominant maintenance cost. Design practice targets a 100000 hour creep rupture basis with statistical scatter, meaning tubes that survive 10 to 15 years in a disciplined plant and far less in one that runs hot excursions; every sustained 20 degrees C above design roughly halves creep life. The specification should state tube grade, calculated life basis, skin thermocouple coverage, and the trip philosophy on high tube skin temperature, and the buyer should ask for the creep design point explicitly. Catalyst life runs 3 to 7 years between reloads, set mostly by feed poison discipline and thermal cycling.
Standards ride on the pressure parts and the burner system rather than on the chemistry. Reforming tubes, headers, and pigtails are built to fired heater and refinery piping codes, with material specifications for the cast alloy grades and welding qualification on high nickel castings; the steam system components follow power boiler practice on the waste heat boiler and steam drum; burner systems follow combustion safety standards with flame safeguard and fuel trip logic; and relief systems across the plant, on the steam side, process side, and PSA, ride safety relief valves sized on agreed scenarios. Emissions permits define the NOx and carbon monoxide numbers the burners must guarantee. None of these are exotic; all of them are frequent scope gaps between packages.
Performance testing closes the specification. Acceptance runs measure hydrogen rate and purity, total gas consumption corrected to reference conditions, export steam flow, residual methane, and pressure drop against guarantee, with instruments calibrated beforehand and a defined test duration. Efficiency guarantees should state their basis, lower heating value and fuel plus feed versus feed only, because the two bases differ by more than the margin a careless comparison will celebrate. A reformer that passes a 72 hour performance test with tube skin and flux recorded is a plant whose guarantees became numbers; anything else is a plant whose guarantees are still adjectives.
Chapter 5 / 06
Selection Decision Factors and RFQ Language
Selection starts from the feed and the number. The designer needs the natural gas or off gas analysis including sulfur species and higher hydrocarbons, the hydrogen rate profile including minimum and maximum demand, the delivery pressure and purity the consumer requires, the steam and power context of the site, and the emissions envelope. From those, the configuration choice follows with little freedom: small distributed demand goes compact packaged reformer or electrolysis comparison, refinery scale hydrogen goes a top fired box with PSA, large syngas with oxygen available considers combined or autothermal reforming. Writing these inputs into the RFQ is what makes bid tabulation an engineering exercise instead of a price exercise.
Selection driver
Favored choice
Watch item
Refinery hydrogen, 10-100 kNm3/h
top fired box + PSA
Steam export value vs condensing
Ammonia or methanol syngas
side fired + secondary
Stoichiometric ratio control
Small distributed hydrogen
compact bayonet package
Compare electrolyzer economics
Carbon capture planned
capture ready flue design
Plot space and reboiler steam
High off gas sulfur
deeper feed pretreat
Catalyst poison margin
Utility integration decisions often outweigh equipment choice. Export steam can be a credit into a site header or a condensing burden depending on the balance, and the answer moves the efficiency ranking of offers; boiler feed water quality, the polishing chain behind reverse osmosis, is an owner scope item whose absence from the bid table resurfaces as startup delay; tail gas recovery to the furnace burners is standard but its measurement belongs in the performance basis. Electrical load for compression and PSA switching is small against fuel but belongs in the numbers. Cooling duty for shift effluent and compressor interstages ties to the site cooling system and sets summertime turndown behavior.
The RFQ language that returns comparable offers states the plant boundary and the guarantees explicitly. State feed gas analysis with sulfur, hydrogen rate and turndown, purity and delivery pressure, steam to carbon and tube outlet temperature basis to be quoted, export steam quantity and pressure with the credit basis, NOx limit, the codes and burner safety standards to apply, the scope split between licensor package and owner balance of plant, and the performance test basis including fuel definition. A complete RFQ paragraph reads: hydrogen 40000 Nm3/h at 99.97 percent and 24 bar from the attached natural gas analysis, 40 to 100 percent turndown, PSA purification, export steam up to 40 tonnes per hour at 40 bar as site credit, NOx per permit, performance per agreed 72 hour test on lower heating value basis.
Commercial comparison is only fair on a normalized basis. Offers should be forced onto one table: hydrogen rate and purity, total gas consumption per unit hydrogen on one stated basis, export steam credit, electrical load, tube grade and calculated life, catalyst and PSA adsorbent initial fill and replacement interval, burner NOx guarantee, and the scope boundary line by line. The cheapest offer is very often the one with the thinnest tube life basis or the highest undisclosed flux, and its life cycle cost lands higher through tube replacement and outage risk. Where carbon intensity is priced or regulated, flue and syngas carbon dioxide quantities and capture readiness move onto the same table.
Reliability questions close the selection. How does the plant ride a feed trip and a steam trip, and how fast does it return; what is the single point of failure list, on furnace fans, PSA valves, compressor, and feed pretreat beds; what spares belong in day one inventory, thermocouples, burners, catalyst guard, PSA valve kits; and what does the trip philosophy protect first, tubes or production. A reformer is bought for a decade of uninterrupted duty feeding units that cannot easily stop, and the answers to these questions, more than the efficiency decimal, decide whether it delivers that.
Chapter 6 / 06
Installation, Standards, Failure Modes, and Maintenance
Installation is a heavy industrial erection. The refractory lined furnace box, tube supports and spring hangers, burner piping with double block and bleed on fuel, the waste heat boiler and steam drum with their code hydrostatic tests, PSA skid with switching valves, and the interconnecting alloy piping arrive as engineered items for site assembly under the pressure and piping codes, with refractory dryout and catalyst loading as schedule critical specialists. Commissioning follows a written sequence: flushing, drying and inerting, burner management system proving, catalyst reduction with steam and feed according to licensor procedure, steam system blowdown and safety valve float testing, then performance test. The as built tube skin and flux baseline recorded at commissioning is the anchor for tube life management for the next decade.
Failure modes have a known hierarchy. Tube creep rupture and tube skin hot spots lead the list, driven by flame impingement, burner maldistribution, or catalyst deactivation that pushes heat flux into shorter wall sections; carburization and oxidation thin tube walls over years; catalyst poisoning by sulfur or chloride raises tube outlet methane and flux; carbon laydown from low steam ratio excursions blocks tubes and raises pressure drop; pigtail and header fatigue cracks appear after thermal cycling; PSA valve wear leaks adsorbent beds; and steam side fouling from poor boiler feed water quietly erodes waste heat boiler duty. Nearly all of these announce themselves in trends, tube skin temperature, differential pressure, methane slip, and steam production, before they announce themselves as trips.
Symptom
Likely cause
First response
Rising tube skin temperature
flux maldistribution
Burner balance, catalyst activity check
Rising tube delta P
carbon laydown
Steam air burnout, review S/C control
Methane slip up at constant TOT
catalyst deactivation
Feed poison audit, plan reload
Steam production down
WHB fouling
BFW quality audit, clean boiler
Hydrogen purity down
PSA valve or adsorbent
Valve diagnostic, bed check
Maintenance is planned around the tube life decade. Annual outages cover burner inspection and tuning, tube skin and thermocouple audit, pigtail and support inspection, relief valve testing, and PSA valve overhaul on rotating schedule; catalyst replacement at 3 to 7 year intervals is planned against observed activity; tube replacement at end of creep life is a capital project with a 12 to 24 month lead, watched through the trend data so it is scheduled, not forced. Spares strategy holds thermocouples, burner tips, PSA valve kits, and guard bed material. The plants that reach 15 year tube lives are the ones that never normalized away a 10 degree creep in tube skin temperature.
Operational stewardship is what the purchase actually bought. Trend tube skin temperatures, tube outlet temperature, methane slip, steam to carbon ratio on analyzer, flue gas oxygen and carbon monoxide, and export steam against the commissioning baseline; keep feed pretreatment discipline absolute, because a sulfur excursion is a catalyst life event; train operators on trip philosophy and hot restart limits; and requote efficiency yearly against the performance test to catch drift. Sites that treat the reformer as a sealed furnace age it at the rate of their worst excursion, and sites that trend it spend their maintenance money on schedule instead of on surprises.
FAQ
What does a steam methane reformer produce?
It produces a hydrogen rich synthesis gas: methane reacts with steam over nickel catalyst inside fired tubes at 800 to 900 degrees C, yielding hydrogen plus carbon monoxide, with the water gas shift reaction immediately adding hydrogen and carbon dioxide. Downstream shift converters raise the hydrogen share further, and pressure swing adsorption typically delivers hydrogen above 99.9 percent purity. For ammonia or methanol service the gas is conditioned to the synthesis ratio instead of purified to pure hydrogen.
What steam to carbon ratio should the design use?
Natural gas duties typically run 2.5 to 3.5 moles of steam per mole of carbon, high enough to suppress carbon formation on the catalyst and low enough not to waste heat. Modern designs push toward 2.0 to 2.5 with advanced catalyst and tight ratio control to improve efficiency. Heavier feeds such as naphtha need higher ratios. The ratio basis should be stated and guaranteed in the RFQ because it moves both efficiency and coking margin.
How long do reformer tubes last?
Design basis is typically a 100000 hour creep life, which translates to 10 to 15 years in a well run plant. Sustained operation above design tube skin temperature spends creep life roughly twice as fast for every 20 degrees C of overheat, so burner balance and skin thermocouple coverage govern realized life more than any design margin. Tube replacement is a capital project with long lead time and should be planned from trend data, not forced by failure.
How does a steam methane reformer compare with a hydrogen electrolyzer?
The reformer is the low cost large scale incumbent, consuming natural gas as both feed and fuel and emitting carbon dioxide from a concentrated flue gas stream that is capture ready. An electrolyzer splits water using electricity, suits small footprint and renewable power contexts, and avoids direct process emissions when the power is clean. At large hydrogen rates with natural gas available, the reformer usually wins on cost per kilogram today; the comparison should be made on delivered hydrogen cost including carbon cost for the specific site.
What feed pretreatment does a reformer need?
Sulfur must be removed to below roughly 0.1 ppm, typically by hydrodesulfurization over cobalt molybdenum catalyst followed by zinc oxide beds, because nickel reforming catalyst is poisoned by sulfur. Chloride and heavy metal guards follow on susceptible feeds. Higher hydrocarbons are acceptable within the catalyst and steam ratio design but must be quantified in the feed analysis. Skipping or underdesigning pretreatment is the fastest way to lose catalyst and, indirectly, tube life.
What is export steam in a reformer plant, and why does it matter commercially?
The syngas leaving the tubes at near 900 degrees C and the furnace flue gas both carry recoverable heat, which the plant converts to high pressure steam in the waste heat boiler; the process consumes part of it as reforming steam and the balance is exported to the site header. Whether that export is a credit or a disposal problem depends on the site steam balance, and it moves the net efficiency ranking between competing offers, so the RFQ should state export quantity, pressure, and the credit basis explicitly.
Can a steam methane reformer be made carbon capture ready?
Yes, and it is among the easier capture retrofits in industry. The flue gas carries carbon dioxide at roughly 8 to 20 percent by volume, and the shifted syngas stream is even more concentrated before purification, so capture studies evaluate one or both streams. Capture readiness means plot space, duct and tie in provisions, and above all spare steam for the capture reboiler, since the reformer's own steam balance is usually already committed; buyers with carbon targets should specify these provisions in the initial RFQ.