A gas turbine is a continuous flow internal combustion engine that compresses ambient air, burns fuel in it, and expands the hot products through a turbine, delivering shaft power to a generator or a driven machine. In industrial form it arrives as a packaged plant: the turbine itself, its inlet air filtration, its combustion and fuel systems, its exhaust case, and the controls that start, load, and protect it, built in heavy duty industrial frames and in lighter aeroderivative machines derived from aircraft engines. GE Vernova's gas turbine portfolio, including its 6B heavy duty machine, and Siemens Energy's SGT-800 and its aeroderivative and heavy duty offerings are the reference catalogs of the class, and this page treats the turbine package and its integration as the purchasing object.
This page is written for the engineer specifying a gas turbine for power generation, combined cycle, or mechanical drive duty. It works through how the Brayton cycle sets the machine's performance, what distinguishes heavy duty from aeroderivative classes, which parameters on vendor data sheets move the economics, and the selection factors and RFQ language that decide whether the installed machine meets its output and heat rate guarantees at the site's real conditions.
The decision concentrates in five places: the power or drive duty required, the fuel and its quality, the site's ambient and altitude, the exhaust energy's value as steam or process heat, and the emissions and start requirements the permit and the grid impose. Get those right and the machine class, rating, and cycle configuration follow.
Chapter 1 / 06
What a Gas Turbine Is and What Is Being Decided
The industrial machine this page describes has three core sections on one shaft line. The compressor, an axial machine of fifteen to twenty or more stages on heavy frames, takes ambient air to fifteen to more than twenty times atmospheric pressure; the combustors, cans or annular chambers, burn fuel in that air and raise the gas toward the materials' limits; and the turbine stages expand the hot gas back toward atmospheric, extracting the shaft power that drives the compressor and the load. The remaining energy leaves as hot exhaust, roughly 450 to 600 degrees Celsius on modern machines, which is either wasted up a stack in simple cycle or recovered in a heat recovery steam generator for combined cycle and cogeneration duty. Power ranges span from a few megawatts on small industrial machines to several hundred on the largest heavy frames.
What is being decided when a gas turbine is purchased is an output and efficiency guarantee at the site's conditions, plus the integration that monetizes the exhaust. The buyer is purchasing a stated kilowatt or megawatt output and a stated heat rate, the fuel energy per unit of power, at stated ambient, altitude, and inlet conditions, with stated emissions, stated start and load behavior, and a stated maintenance structure whose hot gas path intervals set the ownership economics. Everything on the vendor data sheet, rating and heat rate at reference conditions with the correction curves, exhaust flow and temperature, emissions class, start time, exists to support those guarantees, and the five decisions this page works through determine whether the installed plant earns what the model promised.
The gas turbine occupies a specific place in the prime mover landscape and its boundaries matter. It is not a steam turbine: that machine expands water vapor on a Rankine cycle fed by a boiler, and this site's steam turbine page states plainly that it is not a gas turbine; the two run as a pair in combined cycle plants, the gas turbine's exhaust raising the steam that drives the other machine. It is not the heat recovery steam generator, which is the exhaust side boiler and its own product class with its own page, nor the fired heater of process plants, which burns fuel for process heat without making shaft power. And where a site discusses microgrid arrangements mixing turbines, renewables, and storage, the discussion is color around this machine's dispatchability, not a different product: the gas turbine remains the fast, fuel flexible machine at the center.
Different buyers buy the same machine for different reasons. A utility buys heavy frames for combined cycle base load, where efficiency per megawatt dominates. An industrial site buys a mid size machine for cogeneration, power plus process steam from the exhaust. A pipeline compressor station buys mechanical drive machines, often aeroderivative, whose shaft turns a centrifugal compressor on the gas line. A peaking plant buys simple cycle machines for fast starts and few hours. An offshore platform buys aeroderivative packages for weight and compactness. The specification language differs, but the cycle physics is shared, and the paragraphs that follow keep all of these buyers in view.
A short tour of named duties makes the machine concrete. At a combined cycle site, a heavy frame exhausts into a heat recovery steam generator, the steam raises a steam turbine, and the pair feeds the grid through a power transformer at combined efficiencies in the mid fifty percent band and beyond. At a refinery, a cogeneration machine's exhaust makes steam for the process while the shaft turns the generator, and an economizer and air preheater trim the plant's heat balance. At a compressor station, an aeroderivative drives the gas compressor through a gearbox, with the station's controls holding line pressure. At a mine site, a simple cycle machine runs the camp and the mill on distillate where no gas line reaches. In each duty the same five knobs appear: duty, fuel, site, exhaust value, emissions.
A short paragraph on the machine's commercial shape belongs in an engineer's page because it changes what is specified. Gas turbines are bought inside long relationships: the OEM prices the hardware against a service structure that spans its life, the hot gas path parts and the outage labor arrive as contracted scope, and the performance guarantees are coupled to the maintenance regime that preserves them. A buyer who treats the machine as a one time capital purchase and the service as an unplanned expense has mispriced the product by design, and the specification that states the duty cycle honestly, hours, starts, fuel, is what lets both sides price the same machine.
The purchase is never the turbine alone, and the RFQ that forgets the balance of plant buys a very expensive stack ornament. The inlet filtration that keeps the compressor clean, the fuels treatment that keeps the combustors and hot path healthy, the exhaust integration or the stack, the acoustic treatment the neighbors require, and the electrical or driven machine interface are one system with the turbine; and the maintenance structure, parts, labor, and long term service agreements, is as much a purchase decision as the machine itself, because the hot gas path will be serviced several times inside the first decade whatever the datasheet says.
Chapter 2 / 06
How the Brayton Cycle Does the Work
The cycle is compression, combustion, expansion. Work goes into the air in the compressor, heat is added at near constant pressure in the combustors, and the turbine extracts work from the hot gas as it expands; the difference between turbine work and compressor work is the net shaft output, typically a quarter to a third of the turbine section's own gross work, and the exhaust leaves with the unrecovered energy. Two parameters dominate the cycle's quality: the pressure ratio the compressor achieves and the firing temperature the materials and cooling tolerate, and modern machines push both, with firing temperatures in the 1400 to 1600 degrees Celsius class on the most advanced heavy frames, enabled by thermal barrier coatings, film cooled airfoils, and single crystal alloys in the hottest rows.
Heat rate is the efficiency statement and the economics number. Simple cycle efficiency runs roughly the low thirties to about 40 percent in modern machines, expressed as heat rates of roughly 8,500 down to 9,000 kilojoules per kilowatt hour and better; combined cycle plants, by recovering the exhaust into steam and a bottoming cycle, reach the high fifties in percent. Every point of heat rate is fuel money for the machine's whole life, which is why the guarantee basis, the reference conditions and the correction curves to site conditions, carries contractual weight: output and heat rate are quoted by OEMs at stated reference conditions and corrected with published curves, and the specification applies those curves to the site's design ambient and altitude rather than accepting the brochure's day.
Site conditions move the machine more than any other single factor in the specification. Hot air is thin air: output falls and heat rate rises with ambient temperature, a machine loses roughly a fifth of its output from a cool reference day to a hot afternoon in some classes, and evaporative or chilling inlet cooling buys some of it back where water and economics allow. Altitude thins the air the same way, and inlet pressure drops from filtration and silencing cost their share. The honest plant model runs the correction curves against the site's actual ambient distribution, hour by hour across a year, because the revenue is earned on that distribution, not on the reference day.
Inlet cooling is the lever that buys the hot day back. Evaporative coolers and fogging systems cool the inlet air toward its wet bulb, returning a useful share of the density, and therefore the output, that the afternoon took; chilling systems, absorption or mechanical, take the inlet further toward the machine's design conditions at the cost of energy and complexity. The economics are site arithmetic, water availability against the value of the recovered megawatts during the hours that set the plant's revenue, and the specification states the inlet conditions with and without the cooling option so the guarantee basis is unambiguous about which day is being promised.
Combustion and emissions are a technology class of their own. Modern dry low NOx combustors premix fuel and air to hold flame temperatures down, achieving NOx emissions in the tens of parts per million class without water or steam injection, with lean lean and staged modes covering the operating range; wet systems and diffusion combustors with abatement remain for special fuels and duties. Carbon monoxide and unburned hydrocarbons follow the combustor's operating point, and the emissions envelope interacts with turndown, which is why the permit's limits across the load range, not just at full load, belong in the specification. Downstream of the machine, selective catalytic reduction cleans the exhaust further where the permit demands it, and the exhaust stack's dispersion is its own study.
Fuels span a wide band and set the hot path's life. Natural gas is the design fuel for most modern machines; liquid distillates serve backup and off grid duty with their own storage, treatment, and emissions behavior; hydrogen blends and syngases serve decarbonization and process integration with combustor and materials adaptations the OEM must qualify. Fuel quality matters at the parts per billion level for some contaminants: alkali metals and vanadium corrode hot path alloys at temperature, and liquid fuels carry their own centrifuge, washing, and inhibitor chemistry. The fuel specification, composition, contaminants, and variability, is as much a purchase document as the machine's datasheet.
Start, load, and control behavior close the operating picture. Heavy frames start and load in the tens of minutes, suited to duty cycles that plan their starts; aeroderivative machines start in about ten minutes and accept aggressive cycling, which is why they own fast reserve and offshore duty. Governing holds speed and load with the grid or the driven machine, the protection system watches vibration, temperatures, and flame, and the wash systems, offline water washes and online abrasive or water injection, manage the compressor fouling that otherwise slowly eats both output and heat rate between services.
Chapter 3 / 06
Machine Classes, Drives, and Duty Boundaries
Heavy duty industrial frames are the workhorses of power generation: robust, high output, optimized for continuous duty and long hot gas path intervals, with the largest frames exceeding 500 megawatts and the mid classes serving industrial cogeneration. They are built for the ground, maintained in place, and owned on fuel efficiency and maintenance economics. GE Vernova's heavy duty portfolio and Siemens Energy's industrial and heavy duty lines are the reference catalogs, with machines like the 6B occupying the mid size industrial duty for decades of installed base.
Aeroderivative machines carry aircraft engine cores in industrial packages: lighter per megawatt, faster starting, more tolerant of cycling and load swings, and maintainable by core exchange, which suits peaking, fast reserve, offshore, and remote duty where a heavy frame's crane and crew cannot go. Their outputs run from tens to around a hundred megawatts across the class. Small industrial turbines, the few to tens of megawatts class, serve compressor stations, small plants, and mechanical drive with simple robust cycles.
Machine class
Output band
Cycle character
Where it wins
Heavy duty industrial frame
70 to 500+ MW
high firing temp, long service intervals
Combined cycle and base load power
Aeroderivative package
20 to 100 MW class
fast start, cycling tolerant
Peaking, reserve, offshore, remote
Small industrial turbine
2 to 20 MW
simple robust cycles
Mechanical drive, small plants
Micro turbine
30 to 300 kW
recuperated small cycles
Distributed and building scale duty
Drive configuration is the other fork. Generator drive machines turn an alternator at the grid's speed or through a gearbox, feeding the electrical system through a power transformer, and their specification lives in the electrical world's ratings and protections. Mechanical drive machines turn process equipment directly, most commonly a centrifugal compressor on a pipeline or in a process train, often through a gearbox with its own service scope, and their specification lives in the driven machine's map. The same core machine classes serve both, and the OEM catalogs publish both configurations, but the plant around them differs enough that the RFQ must state which world it is buying for.
Cycle configuration completes the type decision: simple cycle, where the exhaust goes up the stack and the machine is bought for starts, simplicity, or capital; combined cycle, where a heat recovery steam generator raises steam for a steam turbine and the pair is bought for efficiency; and cogeneration, where the exhaust's steam serves process heat with or without a condensing bottoming cycle. The exhaust's 450 to 600 degrees Celsius is the resource these configurations allocate, and its value, fuel displaced in boilers, power added in a steam turbine, is the site's economics to state. The fired heater and process heater neighbors appear where the site burns fuel for heat alone, and the economizer and air preheater trims belong to the boiler plant the exhaust may be displacing.
Chapter 4 / 06
Key Specification Parameters
Vendor quotations revolve around a compact parameter set, and a buyer who reads them against the site model can compare offers on engineering terms. The table below collects the parameters that decide performance for mainstream industrial duty, with the ranges a reviewing engineer should expect across modern classes.
Parameter
Typical specification range
What it decides
Rated output at site conditions
2 to 500+ MW by class
The duty and revenue basis
Heat rate, simple cycle
about 8,500 to 10,500 kJ/kWh
Fuel per megawatt for the machine's life
Exhaust gas flow
tens to 2,000+ kg/s by size
HRSG sizing and cogeneration steam
Exhaust temperature
450 to 600 C class
Recovered energy quality
Pressure ratio
about 10 to 20+ by machine
Cycle efficiency character
NOx emissions class
DLN, tens of ppm band
Permit compliance across load
Start time to full load
10 min aero to tens heavy
Duty cycle suitability
Fuels capability
gas, distillate, H2 blends, syngas
Fuel plan and hot path life
Hot gas path interval
8,000 to 24,000 EOH class
Maintenance economics
Noise and envelope
site specific with package
Neighbors and permitting
Two of those numbers do the economic work. Heat rate sets the fuel per megawatt hour for the machine's life, and the guarantee's correction basis, how the number moves with ambient, load, and inlet condition, is where comparable offers actually differ. Exhaust energy, flow times temperature, sets the cogeneration and combined cycle value: how many tonnes per hour of process steam the heat recovery steam generator raises, or how much the bottoming cycle adds, and a machine's output bought without its exhaust character is half a purchase.
The remainder of the parameter set carries the operating reality. Start time and cycling tolerance decide whether the machine serves reserve or base; the emissions class across the load range decides the permit; the fuel capability and its contaminant limits decide the fuel contract the site can sign; and the hot gas path interval, with its equivalent operating hour logic that counts starts and trips as hours, sets the maintenance economics that the long term service agreement prices. The instrumentation and control scope, the vibration sensor suites and the monitoring the OEM's diagnostics read, is the machine's nervous system and belongs in the boundary of supply stated explicitly.
Chapter 5 / 06
Selection Decision Factors and RFQ Language
Duty definition comes first because class follows it. The specification should state the power or drive requirement with its load profile, base load, cycling, or reserve, the annual hours and starts expected, and the machine's role, grid generation, islanded industrial power, cogeneration with a stated steam demand, or mechanical drive on a stated driven machine. The exhaust's intended use, steam raised, process heat, or stack, and the steam system it integrates with, with its steam drum and economizer arrangement where a boiler plant exists, belong in the same paragraph, because they configure the plant the turbine sits in.
Site and fuel context come second. State the ambient distribution and altitude the rating must carry, with inlet cooling options if the site's water and economics allow them; the fuel, its composition and contaminant band, its variability, and any secondary fuel with its probability of use; the emissions limits the permit imposes across the load range; and the acoustic and plot constraints. State the grid or driven machine interface, the electrical connection and its transformer scope, or the driven compressor's map and the gearbox arrangement, because the mechanical drive world buys the same turbine with different plumbing.
Selection factor
What to specify
Common mistake
Duty profile
load, hours, starts per year
Base class machine bought for cycling duty
Site conditions
ambient distribution, altitude, inlet
Rating applied at reference instead of site day
Exhaust integration
HRSG steam duty or process heat
Turbine chosen before the steam balance
Fuel
composition, contaminants, secondary
Hot path life priced on a fuel never analyzed
Emissions
permit limits across load range
Full load compliance, part load violation
Maintenance structure
intervals, parts, LTS A scope
Service agreement treated as an afterthought
Interface scope
electrical or driven machine boundary
Gearbox or transformer scope left between contracts
RFQ language that produces comparable offers follows from those factors and should read like a plant basis document. State the duty and site model, the fuel specification, the emissions regime, the exhaust integration, and the interface boundary. Ask every OEM to state output and heat rate at the site's design conditions using its published correction basis, exhaust flow and temperature at those conditions, emissions across the load range, start and cycling behavior, the maintenance intervals with the equivalent hour logic, the long term service options with their scope and pricing basis, and the reference machines on the same fuel and duty.
Guarantees and acceptance close the procurement. A defensible offer guarantees output and heat rate at stated site conditions with the correction curves' basis, emissions across the operating range, and the maintenance intervals' basis, demonstrated through the commissioning performance test against the guarantee protocol the contract fixed. Hold every bidder to the same site and fuel basis, weight offers on life cycle cost, fuel, maintenance, and availability, over package price, and staff the performance test's instrument plan at contract time, because the megawatts and the heat rate are money from the first operating hour.
Fuel transition planning deserves a line in every modern specification even where the fuel today is ordinary. OEMs qualify their machines for hydrogen blends at stated percentages and are extending those ranges across their catalogs, and a plant whose gas supply may decarbonize over a twenty year life buys differently from one whose fuel is fixed. The specification states the fuel today, the credible fuels of the machine's life, and asks for the qualification basis of each, so the combustor, materials, and safety scope of the purchase already contain the plant's future rather than pricing it as a retrofit surprise.
The plant around the machine deserves its own closing inventory because turbines buy infrastructure. The heat recovery steam generator's steam feeds a steam drum and boiler feed pump train with its economizer trim, the condensing end of the bottoming cycle runs to a surface condenser, and the black start capability that keeps the site independent is usually a diesel generator sized for the auxiliaries, started and synced while the grid is dark. Compressed air for the start sequence and washing comes from a screw compressor skid, the fuel gas's quality is watched by a dew point transmitter and moisture analyzer where liquid carryover threatens the combustors, and the measurement spine, a flow meter on fuel, temperature transmitter sets on exhaust and bearings, pressure transmitters across the inlet and the machine, and the vibration instrumentation already named, lands in the historian that the performance model lives in.
The balance of plant the RFQ must not forget: the inlet filtration with its stages and weather protection, the fuels treatment and forwarding, the exhaust integration or stack with its acoustic scope, the starting means, the washing systems that keep the compressor clean, the fire protection, and the monitoring and diagnostics scope that turns the machine's instrumentation into the OEM's remote care. On cogeneration duty the heat recovery steam generator is its own package with its own page, and on drive duty the gearbox, its bearings and its service, is the mechanical heart between the turbine and the process.
Chapter 6 / 06
Installation, Standards, Failure Modes, and Maintenance
Installation is a heavy industrial project. Foundations carry the machine's mass and dynamics; the inlet and exhaust ducts, the filtration house, and the acoustic enclosures set the plot; the fuels, starting, and washing systems arrive as skids to interconnect; and the driven machine or generator alignment closes the train. Commissioning runs the machine through its start and load sequence, tunes the combustor across its operating range, and executes the performance test at guarantee conditions with the fuel and instruments the protocol names.
Standards shape the machine through several regimes at once. Rotating machinery procurement and test practices govern the guarantees and the witness tests serious buyers attend; pressure equipment and piping codes govern the systems around the machine; emissions authorities govern what leaves the stack; and grid codes govern the electrical behavior, the fault ride through and frequency response, that generation machines must demonstrate. OEM pages present ratings at stated reference conditions with published corrections, as GE Vernova and Siemens Energy do throughout their catalogs, and the specification's job is to apply those bases honestly to the site; a buyer cites the regimes by name and demands the compliance map, not guessed clause numbers.
Failure mode
Signature
Response
Compressor fouling
output and heat rate drift down
Inlet filtration audit, online and offline wash program
Hot gas path distress
rising temperatures, borescope finds
Scheduled hot path service, parts plan, coating repair
Combustor dynamics or instability
pressure oscillation alarms
Tuning across range, hardware per OEM service bulletins
Fuel contaminant corrosion
blade distress at inspection
Fuel treatment, specification enforcement, inhibitor program
Weather protection, anti icing, filter maintenance
Routine operation is trend led. Output and heat rate corrected to reference conditions, compressor pressure ratio, exhaust temperature spreads across the combustor cans, vibration signatures, and wash history together tell the plant what the machine is doing between services, and the OEM's diagnostics read the same trends remotely on contracted machines. Maintenance is interval and condition based: combustion inspections and hot gas path overhauls at the equivalent operating hour intervals the service structure prices, borescope inspections between them, the wash program continuous, and the parts supply a planned economy rather than an emergency.
The end state of a well specified gas turbine is a plant whose economics the finance team can model and whose performance the operators trust. The machine holds its output through the hot afternoon because the correction curves were applied, the exhaust pays the boiler bill because the integration was designed, the permit holds across the load range because compliance was specified there, and the maintenance arrives on a schedule the service agreement priced years before. The neighbors mark the boundaries: steam cycles own the boiler's world, diesels own the fast small standby, and this machine owns the fired continuous megawatt.
FAQ
Heavy duty or aeroderivative: which class fits my plant?
Heavy duty industrial frames suit base load and combined cycle duty: highest outputs, best simple cycle efficiencies at scale, and long hot gas path intervals, maintained in place. Aeroderivative machines suit fast starts, cycling, peaking, offshore, and remote duty: about ten minute starts, core exchange maintenance, lighter packages, and cycling tolerance the heavy frames must be operated gently to match. The duty profile, hours, starts, and plot, decides the class before any OEM is called.
What is heat rate and why does it dominate the economics?
Heat rate is the fuel energy the machine consumes per unit of power, roughly 8,500 to 10,500 kilojoules per kilowatt hour in modern simple cycle classes, and it is the operating cost number: fuel is the largest lifetime expense of a gas turbine plant. The guarantee basis matters as much as the number, since output and heat rate are quoted at reference conditions and corrected with curves to site conditions, and two offers corrected to different site bases are not comparable.
Can the exhaust really make steam and power?
Yes, that is half the machine's value in industrial plants. The 450 to 600 degrees Celsius exhaust carries most of the fuel's energy, and a heat recovery steam generator converts it to process steam in cogeneration or to steam turbine power in combined cycle, lifting total plant efficiency to the high fifties in percent in the best combined configurations. Specifying the turbine without specifying the exhaust's destination is specifying half a plant.
What fuels can a gas turbine burn?
Natural gas is the design fuel of the modern class, with distillate as the common backup, and hydrogen blends and syngases qualified by OEMs at stated ranges with combustor adaptations. Fuel quality is a specification item at the contaminant level: alkali metals, vanadium, and sulfur compounds attack hot path alloys and set the treatment chemistry. The fuel plan, primary, secondary, and its variability, belongs in the RFQ with the machine's qualification basis.
How fast can a gas turbine start and take load?
Aeroderivative packages start and load in about ten minutes, which is why they own fast reserve duty. Heavy frames need tens of minutes through their start sequences, suited to planned duty cycles rather than minute scale response. Starts count against maintenance intervals through equivalent operating hour logic, so the start frequency the plant plans is part of the machine's economics and part of the service agreement's pricing.
What maintenance does a gas turbine need, and how often?
The hot gas path, combustors, blades, and vanes, is serviced at intervals in the 8,000 to 24,000 equivalent operating hour class depending on machine and duty, with combustion inspections between major overhauls and borescope inspections in between those. Compressor washing, online and offline, runs continuously against fouling, and the diagnostics program watches trends between services. Long term service agreements with the OEM are the standard structure, and their scope and pricing are a purchase decision, not paperwork.
How much does ambient temperature affect output?
Materially: hot ambient air is less dense, and machines lose roughly a fifth of their output from a cool reference condition to a hot afternoon in some classes, with heat rate rising alongside. Altitude thins air the same way, and inlet filtration pressure drop takes its share. The correction curves in the OEM's published basis quantify it, and the specification applies them to the site's design conditions, with inlet cooling bought where water and economics justify it.