Sour Water Stripper

A sour water stripper is the refinery or gas plant column that cleans sour water, the process condensate loaded with hydrogen sulfide and ammonia that drains from hydrotreating, FCC, coking, and amine operations, by stripping the acid gases out with steam: feed, after degassing and oil removal, enters the column where rising steam and heat liberate hydrogen sulfide and ammonia from the water, the overhead vapor, condensed and refluxed, leaves as a sour gas stream routed to the sulfur recovery unit, and the stripped water leaves the bottom clean enough to reuse in the plant or to treat in the wastewater system. Single-column machines handle the common duty; two-column designs separate an ammonia-rich and an acid-rich stream where the destination demands it. Sulzer's amine treating and sour water stripping literature is a representative reference, and this page treats the complete machine, column, internals, overhead system, and reboiler or steam supply, as the purchasing object.

This page is written for the engineer specifying a sour water stripper for a refinery hydrotreating complex, an FCC or coker battery, or a gas plant's water system. It works through what the machine is and what is being bought, how the volatility and the chemistry of the acid gases make the separation, which column designs fit which waters, the parameters that appear on vendor data sheets, and the selection factors and RFQ language that decide whether the stripper meets its H2S and ammonia limits for a fouling and steam budget that stays predictable.

Vapor-liquid separation vessel hardware of the class adjacent to stripper columns, shown as an installed separator

Photo: Didier Duforest, CC0, via Wikimedia Commons

The decision concentrates in five places: the sour water's source mix and its contaminants, sulfides, ammonia, phenols, cyanides, oils, which set the pretreatment and the column's fouling regime, the stripped water specification and the overhead destination, reuse, wastewater, or the sulfur recovery unit, that define the product, the column architecture, single or two columns, that the destination dictates, the steam and heat integration, stripping steam, reboiler, feed exchange, that sets the energy bill, and the internals, trays or packing, that survive the salting and fouling this service is famous for. Get those right and the instrumentation, the materials, and the turnaround scope follow with little freedom.

Chapter 1 / 06

What a Sour Water Stripper Is and What Is Being Decided

The machine this page describes is a vertical distillation column, a few dozen trays or an equivalent packed height in a steel or stainless shell, with a feed point partway up, stripping steam or a reboiler at the bottom supplying the heat and vapor, and an overhead system, condenser, reflux drum, and reflux pump, closing the top; sour water feed, after the sour water tank's degassing and a free oil removal step, often a simple separator or a dissolved air flotation polish on oily waters, enters the column, and as it descends against the rising steam, hydrogen sulfide and ammonia leave the liquid and travel up with the vapor. The overhead, condensed and partly refluxed, leaves as sour gas to the sulfur recovery unit's furnace or to the amine unit's incineration path, and the stripped water leaves the bottom, cooled by exchange with the feed, to reuse or to wastewater treatment.

What is being decided when a sour water stripper is purchased is a stripped water guarantee backed by an overhead routing and an energy statement. The buyer is purchasing a stated hydrogen sulfide and ammonia content in the stripped water, commonly parts per million classes, from a defined sour water analysis at a stated flow, with a stripping steam or reboiler duty the vendor should bound and an overhead composition consistent with its destination. Everything on the vendor data sheet, column diameter, tray count or packed height, steam rate, materials, exists to support those guarantees, and the honest vendor sizes from the water's actual analysis, including its phenols and cyanides, rather than from an analogy to someone else's refinery.

The sour water stripper sits in the refinery's gas and water families with defined neighbors. It is not the amine unit, the gas treating circuit that scrubs acid gas from process gases with amines and regenerates them in its own still, though the two share acid gas destinations and sometimes hardware vocabulary; sour water is a liquid water stream, and the amine unit treats gas. It is not the sulfur recovery unit, the Claus train that converts the acid gases to sulfur, though the SRU is this machine's principal customer and its own page in this encyclopedia already takes sour water stripper gas as an upstream neighbor. And it is not a wastewater biotreatment reactor, though the stripped water often feeds one; the stripper is the physical separation that removes what biology should not have to meet.

Different buyers buy the same machine for different waters. A hydrotreating complex strips condensate loaded from high pressure separators, the three phase separator drains of the reaction section, hydrogen sulfide and ammonia rich from the reactions the units exist to run. An FCC unit strips overhead drum water with its own contaminant signature, phenols and cyanides included. A delayed coker strips blowdown water, oils and solids making the harshest fouling class. A gas plant or hydrogen plant strips shift condensate, leaner and cleaner. A refinery-wide machine takes the mixed sour water tank's blend, the common economy, and the specification language differs by source, but the steam stripping physics is shared.

The economics deserve their own paragraph because the stripper is bought twice, once in capital and forever in steam. Stripping steam or reboiler duty is the operating cost, and the design trades it against column height and internals, more stages buying lower steam for the same water specification; the feed-effluent exchange, a shell and tube heat exchanger recovering stripped water heat into the feed, is the standard energy answer, and a heat recovery steam generator or fired heater elsewhere in the plant often supplies the steam itself. The second economics is reuse: stripped water clean enough to wash or to desalter make-up is water the refinery does not buy or treat, and the specification the buyer sets decides which of the two products the machine makes, a clean water and an acid gas, both worth their steam.

A short tour of named installations makes the machine concrete. At a fuels refinery, mixed sour water from the tank farm degasses and sheds oil, feeds a single-column stripper with twenty-odd trays, steam from the plant header, and an overhead condenser on cooling tower water, the sour gas joining the SRU feed alongside amine unit acid gas. At a deep hydrotreater, high pressure separator water, ammonia rich, feeds a two column arrangement, the first releasing the bulk acid gas, the second concentrating ammonia for destruction or recovery. At a coker, blowdown water strips in a machine designed for oil and solids, extra retention and wash provisions in its design. Each installation names the same knobs, steam, stages, reflux, and routing, with waters that differ while the stripping chemistry barely changes.

Chapter 2 / 06

How Steam, Chemistry, and the Column Do the Work

The chemistry is acid-base, and it decides everything. Hydrogen sulfide and ammonia coexist in sour water partly as dissolved gases and partly ionized; heat and stripping steam drive the dissolved fractions out of solution, but the ionized fractions, bisulfide and ammonium ions, respond to pH, and the two contaminants oppose each other, the pH that frees sulfide protonates ammonia into the nonvolatile ammonium ion, and the pH that frees ammonia keeps sulfide ionized. The operating window accepts the compromise: at the column's temperature the equilibria shift enough toward the volatile forms that both strip, with residence time and steam making up the balance, and the designer who understands the chemistry designs the stages and the steam around it rather than hoping.

Steam is the working fluid in two senses. Live stripping steam, injected at the bottom or sparged through the water, is both the heat source and the carrier vapor, its partial pressure pulling the acid gases with it; reboiled designs generate the vapor in a reboiler instead, keeping the steam system's condensate out of the water balance but adding the reboiler's fouling surface to the machine. The steam rate is the operating dial, more steam, cleaner water, higher overhead load on the condenser and the downstream SRU, and the design point balances the stripped water specification against everything downstream. The overhead condenser partly condenses the vapor, water returning as reflux, and the reflux drum's sour gas leaves to its destination; a steam ejector serves the noncondensable withdrawal or the vacuum variants where design calls for them.

The column internals fight the service's famous fouling. Ammonium bisulfide and ammonium salts condense and deposit where temperatures and concentrations align, salting trays and packing; oils and solids from the feed, especially coker waters, coat surfaces and plug passages; and the result is the service's standing maintenance story, columns opened at turnaround to wash and replace internals. Trays, in generous openings and robust materials, tolerate the service better than fine packing; where packing serves, large-cell random packing and fouling-resistant structured packing classes are the choice, and Koch-Glitsch's tray literature for sour water service represents the internals engineering the duty demands. Wash provisions, drainage, and manway access are design items, not luxuries.

The feed system is half the machine's reliability. Sour water arrives from the plant's drains to a tank where it degasses, hydrogen sulfide flashing to the vapor handling system, and sheds free oil; an oil water separator or skim stage, and on oily waters a dissolved air flotation polish or a cyclone separator deoiling stage, protect the column from the oil that would otherwise salt and coat it. Pumps, generally a sour water pump of ordinary refinery class and a spare, move the feed through the exchanger train, and the feed tank's vent joins the sour gas or flare header through a knockout drum. Plants that shortcut the feed discipline pay for it in the column, and every experienced operator says so.

The overhead routing is a process decision with hardware consequences. Sour gas to the sulfur recovery unit is the classic destination, the stripper's acid gas joining the amine regenerator's as Claus feed, its ammonia content the SRU's design constraint, too much ammonia and the Claus catalyst and the tail gas suffer; sour gas to incineration or to the flare stack suits smaller or remote machines, and the flare's own knockout and smoke disciplines apply. Two column designs exist precisely to shape the overhead, an acid gas column and an ammonia column, where the plant wants ammonia recovery or a cleaner split, and the destination the process chooses names the machine's configuration before any vendor conversation.

Degradation has a short honest list, fouling first. Salting and deposition raise the column's pressure drop and cut its efficiency between turnarounds, hot washes and careful steaming buying time, and the internals design deciding how much; overhead condenser fouling by the same salts shows as rising pressure and falling reflux; feed exchanger fouling by oils cuts the energy recovery and forces the steam up. Corrosion follows the wet acid gases, hydrogen sulfide and ammonium bisulfide aggressive to carbon steel, and the materials ladder, stainless internals, alloy or clad in the aggressive zones, is the standard answer. None of these are exotic, and the machine that runs well is the one whose feed discipline, materials, and wash provisions were bought on purpose.

Chapter 3 / 06

Column Types, Service Classes, and Process Boundaries

Single-column strippers are the standard machine: one column, trays or packing, live steam or a reboiler, overhead to the SRU, stripped water from the bottom, and the whole contaminant load leaving in one sour gas. The design trades steam against stages for the water specification, tolerates the mixed sour water tank's blend, and represents most of the installed base. Its limitation is the overhead's combined load, hydrogen sulfide and ammonia together, which the SRU can accept only to its ammonia tolerance, and where that binds the architecture moves to two.

Two-column designs split the products. A first column, run to favor acid gas release, sends its overhead to the SRU lean in ammonia; the bottoms, ammonia bearing, feed a second column whose overhead concentrates ammonia for recovery, destruction in a dedicated furnace, or disposal to the flare stack or incinerator, and the second column's bottoms are the stripped water. The arrangement buys overhead quality at the price of a second column and its utilities, and it is specified where ammonia recovery has value or where the SRU's ammonia tolerance sets a hard ceiling. Variants, a single column with sidestream withdrawal or absorber enhancements, exist in the engineering literature and the vendor portfolios.

Service classes name the waters. Hydrotreater water, ammonia and sulfide rich, oils low, is the clean duty; FCC and coker waters bring phenols, cyanides, oils, and solids, the fouling duty, and their machines run the heavier internals and the stronger feed pretreatment; gas and hydrogen plant condensates are lean waters on small machines; and the refinery-wide mixed water service blends them all at the tank. Materials and internals follow the class, and the vendor's reference list on the actual water class is the honest selector between tray and packing choices.

The process boundaries deserve precision because the refinery's acid gas systems neighbor each other closely. This machine strips water; the amine unit scrubs gas, and its regenerator still is the amine machine's own column; the sulfur recovery unit consumes both machines' acid gases, Claus chemistry on the burner train, and its page covers that machine; the flare stack and its knockout drum handle the upsets and the smaller machines' routing. Downstream of the stripper, the stripped water may wash, make desalter water, or feed the wastewater plant, where a membrane bioreactor, a sequencing batch reactor, or a moving bed biofilm reactor carries the biological duty the stripper made possible; phenols that survive stripping meet biology or activated carbon there. Each machine has its page; this one is the water column.

Adjacent hardware completes the machine's scope picture. The feed train, tank, degassing, oil removal, pumps, and the feed-effluent exchanger; the overhead system, condenser, reflux drum and pump, and the sour gas line with its knockout; the bottom system, reboiler or steam sparger, bottoms pumps, and the stripped water cooler; and the instrumentation and safety system, level, pressure, temperature, and the relief philosophy landing in the flare header. The RFQ that scopes the machine as this train, not as a shell alone, receives bids that can actually be compared, and the buyer's process package should arrive at the vendors with the water analysis and the destinations already fixed.

Chapter 4 / 06

Key Specification Parameters

The vendor data sheet for a sour water stripper centers on flow, specification, and steam, and each number carries a duty consequence. The table below lists the parameters that recur across engineering packages and vendor quotations, with typical ranges for refinery classes; values for a specific project come from the water analysis and the process design, and the ranges here are orientation, not a substitute for design.

ParameterTypical rangeWhat it decides
Sour water feed rate5 to 150 m3/h by refinery sizeColumn diameter; feed train sizing
Feed H2S content500 to 15,000 ppmwAcid gas load; SRU feed contribution
Feed NH3 content500 to 20,000 ppmwAmmonia load; single versus two column
Stripped water H2S1 to 50 ppmw by specStages and steam; reuse or treat path
Stripped water NH330 to 300 ppmw by specAmmonia duty; downstream biology load
Stripping steam ratio50 to 200 kg steam per m3 waterOperating energy; overhead load
Column pressure0.1 to 0.3 MPa g typicalVolatility; materials; relief design
Internalstrays, 15 to 30; or fouling-resistant packingTurnaround interval; salting tolerance

Three of these numbers deserve the buyer's suspicion when they arrive without a basis. Stripped water guarantees quoted on a cleaner water than the plant's blend flatter the machine, and the analysis belongs in the bid package. Steam ratios quoted without the specification they achieve are half numbers, steam and spec trade along the design's stages. Overhead compositions quoted without stating the destination tolerance, the SRU's ammonia ceiling or the flare's, are physics without process. An RFQ that carries the water analysis and the destinations separates engineered offers from assembled ones.

Materials and construction follow the corrosion discipline. Carbon steel serves the milder zones; stainless internals, 300 series as the baseline in trays and packing, and clad or solid alloy in the aggressive overhead and condensing circuits answer the wet acid gas; the condenser's metallurgy, where ammonium bisulfide concentrates, is the classic pinch point and alloy selection there is a purchase decision with a history. Relief loads land in the flare header per the plant's relief philosophy, and the column's instrumentation, pressure, levels, temperatures, and the analyzer scope on stripped water, is the machine's operating honesty.

Chapter 5 / 06

Selection Decision Factors and RFQ Language

Selection starts with the water and the destinations, not the catalog. The water analysis, sulfide, ammonia, phenols, cyanides, oils, and the flow and its swings from the sour water tank's blend, define the load; the stripped water specification, set by reuse or by the wastewater plant's tolerance, and the overhead destination, the SRU's ammonia ceiling, the flare, or ammonia recovery, define the products; and the two together fix the architecture, single column, two column, or variant. The energy question, live steam versus reboiler, and the feed-effluent exchange, follows the plant's steam and heat balance.

The fouling regime chooses the internals. Clean waters license packing's efficiency and smaller diameters; fouling waters, coker and FCC classes, license trays in robust designs, generous openings, and wash and drainage provisions, and the turnaround interval the refinery plans becomes a design input, a column opened every four years is built differently than one opened every two. Pretreatment scope, degassing, oil removal, and the DAF or deoiling stage on oily waters, is chosen with the column and belongs in the same package. The vendor's reference list on the actual water class, and their internals engineering for it, is the honest selector.

The table below organizes the decision into the factors that recur across projects, with the questions the buyer should be able to answer before the RFQ goes out. Each row is a place where an incomplete answer turns into an underspecified machine and a specification argument later.

Decision factorWhat the buyer must stateConsequence if left open
Water analysisH2S, NH3, phenols, cyanides, oils, flow and swingsLoad assumed; guarantees void
Stripped water specH2S and NH3 limits by destination, reuse or treatStages and steam undirected
Overhead destinationSRU with ammonia ceiling, flare, or recoveryArchitecture unresolved
Energy contextLive steam versus reboiler, feed exchange, steam priceOperating cost unbounded
Fouling classWater source mix, coker or FCC share, turnaround cycleInternals and interval mismatched
PretreatmentDegassing, oil removal scope by water classColumn fouled from day one
MaterialsCorrosion discipline, condenser alloy classBisulfide corrosion failures

RFQ language for a sour water stripper should name the water and the basis of guarantee. A workable specification states: sour water analysis with contaminants and the source mix; design and maximum feed rates; stripped water H2S and ammonia specifications by destination; overhead destination with its tolerance, SRU ammonia ceiling included; architecture intent, single or two column, with internals class by fouling; steam or reboiler duty basis and the feed exchange scope; materials discipline including the overhead and condenser alloys; pretreatment scope in the package; instrumentation and relief interfaces; and the acceptance basis, a performance window at design feed against the stripped water guarantees. Naming the neighbors, the sour water tank and pumps, the amine unit sharing the SRU, the flare header, and the wastewater plant, lets the vendors bid the machine's whole duty.

Chapter 6 / 06

Installation, Standards, Failure Modes, and Maintenance

Installation is a column and piping campaign with a chemistry commissioning at the end. The vessel lifts onto its skirt and foundation, internals, trays or packing, install by the vendor's procedure, and the overhead condenser, reflux drum, exchangers, and pumps set with the refinery's standard piping and steam connections; relief loads land in the flare header per the philosophy. Commissioning proves the systems with water and steam, the column's pressure drop establishing the hydraulic baseline, and then feed introduces the chemistry, the specification checked against the guarantees at stable operation. The sour water tank's degassing and the vent routing prove themselves early, and the first weeks tune the steam rate and reflux to the specification's margin.

Standards for these machines are the refinery's ordinary pressure and process discipline. The column and its exchangers follow the pressure equipment framework of the jurisdiction; relief design follows the plant's relief philosophy to the flare; materials and welding follow the corrosion discipline's specifications; and the process design draws on the engineering practice for sour water service, the vendors' design guides and the industry's sour water literature, rather than a single machine standard. Any edition reference in project documents should be checked against the current issue at purchase rather than copied from an old specification.

The recurring failure modes are salting, corrosion, and the feed's sins. Ammonium salt deposition in internals and the condenser raises pressure drop and cuts efficiency between turnarounds, hot washing and steaming buying time and the turnaround washing and renewing the internals; the condenser's bisulfide attack is the classic metallurgy failure, alloy selection and velocity discipline the prevention; feed excursions, oil and solids past a degraded pretreatment, coat the column and force early intervention. Bottoms pump and level upsets, reflux system faults, and the instrumentation's drift round out the honest list, and the machine's vital signs, pressure drop, temperatures, and the stripped water analyzer, tell all of them early.

Maintenance planning is turnaround driven with online watch between. The table below lists the actions with the typical cadence a refinery will schedule, assembled from common practice; actual intervals follow the water class and the turnaround cycle and should be set from the plant's own record.

ItemTypical actionTypical cadence
Stripped water analyzerVerify H2S and NH3 against labContinuous, weekly lab check
Column pressure dropTrend against clean baselineContinuous to weekly
Overhead condenserMonitor fouling, bisulfide corrosion inspectionsQuarterly review, at TA
Feed pretreatmentCheck tank degassing, oil removal performanceMonthly
Steam and reboiler systemVerify rates, trap function, exchanger dutyMonthly
Relief and flare interfaceVerify per relief philosophyPer MI program
InternalsWash, inspect, renew at turnaroundEach turnaround

Long term care is a fouling and specification story. The machine that meets its stripped water numbers in year fifteen is the one whose feed discipline held, whose condenser alloy was right the first time, and whose turnarounds washed and renewed the internals on schedule; upgrades, fouling-resistant internals, better wash provisions, and feed pretreatment additions, extend legacy columns, and the water specification itself is revisited as reuse value rises. The refinery that treats its stripper as the water and acid gas valve it is, analyzed and trended, is the refinery whose SRU feed and wastewater plant both see the streams they were designed for.

FAQ

What is sour water and why must it be stripped?

Sour water is process condensate that has contacted hydrogen sulfide and ammonia, draining from hydrotreating separators, FCC and coker overheads, amine systems, and shift condensate in hydrogen plants. It cannot be reused or sent to wastewater as it stands, the sulfides are toxic and corrosive, the ammonia loads the biological treatment, and both would violate the plant's permits and poison downstream units. Stripping removes both with steam and returns two usable streams, clean water and an acid gas routed to sulfur recovery or incineration.

What is the difference between a single-column and a two-column sour water stripper?

A single-column stripper removes both contaminants in one machine, sending a combined sour gas overhead, hydrogen sulfide and ammonia together, to the sulfur recovery unit or the flare; it is the standard design where the SRU's ammonia tolerance accepts the load. A two-column design separates the products, the first column releasing acid gas lean in ammonia for the SRU, the second concentrating ammonia for recovery or destruction, bought where ammonia has value or the SRU's tolerance binds. The destinations, not preference, choose the architecture.

Why do sour water strippers foul, and how is fouling managed?

Ammonium bisulfide and other ammonium salts condense and deposit on trays, packing, and condenser surfaces as temperatures and concentrations align, and oils and solids from coker and FCC waters add coatings and plugging. Management is a design and discipline package: robust tray internals with generous openings, fouling-resistant packing where packing serves, effective feed pretreatment, degassing and oil removal ahead of the column, wash and drainage provisions, hot washing and steaming between turnarounds, and full internals renewal at the turnaround itself.

How much stripping steam does a sour water stripper need?

Steam rate trades against column stages for the water specification, with design ratios commonly in the range of tens to a couple of hundred kilograms of steam per cubic meter of water. More steam cleans the water further but loads the overhead condenser and the downstream SRU and raises the energy bill; more stages buy the same specification at lower steam. The honest ratio for a specific water comes from the design's stage-steam trade on the actual analysis, and live steam versus reboiler duty changes the water and condensate balance as well.

Where does the overhead sour gas go?

Most commonly to the sulfur recovery unit, joining the amine regenerator's acid gas as Claus feed, within the SRU's ammonia tolerance; machines whose gas exceeds that tolerance or plants without an SRU route the gas to incineration or the flare stack, the flare's own knockout and smoke disciplines applying. Two-column designs can deliver an ammonia-rich stream separately, to recovery or to a dedicated destruction furnace. The destination is a process decision made before the machine is specified, because it shapes the column.

Can stripped water be reused in the refinery?

Often yes, and that is half the machine's value. Stripped water meeting the plant's specification washes, serves desalter make-up, or feeds the utility water systems in many refineries, displacing fresh water purchases; water that meets only treatment standards goes to the wastewater plant instead, where biotreatment, membrane bioreactors, sequencing batch reactors, and their siblings carry the residual organics, phenols included, that stripping leaves behind. The specification the buyer sets decides which product the machine makes.

What should a sour water stripper RFQ include?

State the sour water analysis with contaminants and source mix, design and maximum flows, stripped water H2S and ammonia specifications by destination, the overhead destination and its tolerance, architecture intent single or two column with internals class by fouling, steam or reboiler basis with feed exchange scope, materials discipline including condenser alloys, pretreatment scope, instrumentation and relief interfaces, and the acceptance basis at design feed. Naming the sour water tank, amine unit, flare header, SRU, and wastewater plant interfaces lets vendors bid the machine's whole duty.

Sources

  1. Sulzer, amine treating and sour water stripper
  2. Sulzer, stripping technology
  3. Koch-Glitsch, SUPERFLUX tray, sour water stripper service
Ask SpecForge AI