A hydrotreater is the refinery catalytic unit in which a hydrocarbon stream, naphtha, kerosene, diesel, gas oil, or a specialty cut, reacts with hydrogen over a fixed bed of sulfided cobalt-molybdenum or nickel-molybdenum catalyst, so that sulfur leaves as hydrogen sulfide, nitrogen as ammonia, oxygen as water, and metals deposit on guard catalyst, producing a clean stream for fuel blending, further processing, or petrochemical feed. The unit is a hydrogen circuit: feed mixed with recycle gas passes heat exchange and a fired heater into one or more trickle-bed reactors, quench hydrogen controls the exotherm between beds, reactor effluent cools and separates into recycle gas, treated product, and sour streams, and the hydrogen sulfide leaves the gas in an amine unit on its way to sulfur recovery. US EPA refining documents describe the process and its emissions as standard practice, and this page treats the complete unit, reactors, catalyst, hydrogen system, and separation, as the purchasing object.
This page is written for the engineer specifying a hydrotreater for clean fuels duty, a feed or capacity change, or a revamp chasing tighter product sulfur. It works through what the unit does and what is actually being bought, how the catalyst and the hydrogen do the work, which design choices such as reactor count, pressure, and catalyst system separate one offering from another, the parameters that recur on vendor data sheets, and the selection factors and RFQ language that decide whether the unit makes its product specification on the stated feed for a catalyst cycle that meets the refinery's turnaround calendar.
The decision concentrates in five places: the feed and its contaminants, sulfur, nitrogen, metals, and the product target they must reach; the reactor severity, hydrogen partial pressure and temperature trajectory, that buys the target at acceptable catalyst life; the hydrogen system, makeup supply, recycle compression, and purity, that sustains the severity; the catalyst system, guard, main, and grading, matched to the feed's metals and fouling; and the downstream sour-gas handling, amine treating and sulfur recovery, that takes what the unit removes. Get those right and the cycle length and yields follow with margin.
Chapter 1 / 06
What a Hydrotreater Is and What Is Being Decided
The machine this page describes is a reaction train inside a hydrogen loop. Liquid feed from the electrostatic desalter's downstream tankage, or straight from a crude unit cut, mixes with hydrogen-rich recycle gas, passes through a shell-and-tube heat exchanger train recovering effluent heat, reaches reaction temperature in a fired heater, and flows down through fixed catalyst beds in one or more heavy-wall reactors; between beds, cold quench gas controls the temperature rise the exothermic reactions generate. Effluent gives its heat back to the feed in exchange, cools, and separates in a high-pressure separator and lower-pressure drums into a recycle gas stream, a sour water stream carrying ammonia, and the treated hydrocarbon product for stripping of residual light ends and sulfur species. A reciprocating or centrifugal recycle compressor moves the gas loop; makeup hydrogen arrives from the refinery's reformer or a steam methane reformer, or increasingly from a hydrogen electrolyzer on low-carbon sites.
What is being decided when a hydrotreater is purchased is a product specification with a cycle statement. The buyer is purchasing the ability to take a stated feed at a stated rate to a stated product sulfur and nitrogen, ULSD's ten parts per million among the famous targets, at a hydrogen consumption within a stated band, for a catalyst cycle length that fits the refinery's turnaround calendar before regeneration or replacement. Everything on the vendor data sheet, reactor volume, pressure, temperature, catalyst volumes, hydrogen consumption, exists to support that statement, and honest licensors size from pilot or commercial data on the actual feed rather than by copying the last project.
The hydrotreater sits in the refining family with well-defined neighbors that this encyclopedia treats separately. It is not a hydrocracker, the higher-pressure sibling that cracks as it treats and which this batch deliberately leaves to its own future page; the hydrotreater treats with minimal boiling-range change, a few percent light ends aside. It is not a steam methane reformer, which makes its hydrogen, only a consumer of it; not the amine unit that scrubs its sour gas, nor the sulfur recovery unit that converts the hydrogen sulfide to elemental sulfur, though both are its inseparable downstream; and not the delayed coker, whose coker naphtha and gas oil are among its feeds. Its own front door is often the crude unit and the electrostatic desalter that prepared the feed's feed, and its sour water goes to the sour-water stripper, its light ends to the gas plant, with upsets to the flare-stack.
Different buyers buy the same unit for different feeds. A naphtha hydrotreater protects a catalytic reformer, removing sulfur that would poison its platinum, at moderate severity and small hydrogen consumption. A distillate hydrotreater makes on-road diesel, and the ULSD era pushed these units to higher pressure, better catalysts, and deeper stripping to hold ten parts per million sulfur on hard feeds. A gas oil hydrotreater pretreats FCC feed for sulfur and saturated-gun catalyst protection at higher severity. A specialty unit treats kerosene for jet fuel or lube precursors, and a pre-treater protects a downstream unit's catalyst, the hydrogen feed purification duty of the steam methane reformer family being the mirror image. The feed writes the severity, the catalyst, and the price.
The economics deserve their own paragraph because hydrogen is the currency the unit spends. Hydrogen consumption scales with the sulfur and nitrogen removed and with the saturation the severity demands, and every thousand standard cubic feet is a cost the reformer or the SMR charged to make; severity bought with pressure and catalyst at lower temperature conserves both hydrogen and cycle life. Catalyst spend follows cycle length, and regeneration or replacement at turnarounds is a planned capital rhythm. The product's value is compliance and blend security, the ability to sell ULSD or protect a reformer, which is why the unit is bought against regulation-driven targets and why its guarantee language is the contract that matters.
A short tour of named duties makes the unit concrete. At a fuels refinery, straight-run and cracked diesel from the crude unit and the conversion units, desalted and stripped, mixes with recycle hydrogen at sixty to eighty bar, reacts over graded nickel-moly beds, strips to ten parts per million sulfur, and blends to the diesel pool, with sour gas to amine and sulfur. At a naphtha unit, full-range naphtha desulfurizes gently ahead of the reformer. At an upgrading site, bitumen-derived gas oil hydrotreats at severity limited by its nitrogen and metals. Each duty names the same knobs, pressure, temperature, catalyst, and hydrogen, with numbers that climb while the trickle-bed physics never changes.
Chapter 2 / 06
How Catalyst, Hydrogen, and Heat Do the Work
The chemistry is hydrogenolysis over a sulfided surface. Cobalt-molybdenum catalyst, sulfided in place at startup, removes sulfur from thiophenes and mercaptans as hydrogen sulfide; nickel-molybdenum and nickel-tungsten systems add hydrogenation strength for nitrogen, aromatics, and the hardest sulfur species; and the reactions are exothermic, a few tens of degrees of bed rise, which the design lives with by quenching between beds. Nitrogen leaves as ammonia, oxygen as water, chlorides as hydrogen chloride caught by guard material, and metals, nickel, vanadium, arsenic, and silicon from upstream treatments, deposit irreversibly on demetallization guard catalyst, which exists to die so the main catalyst does not.
Hydrogen partial pressure is the severity axis that buys everything. Higher pressure pushes equilibrium toward the treated product, suppresses catalyst coking, and extends cycle life, at the capital cost of heavier reactor walls and the operating cost of compression; the designer picks a pressure class for the feed's refractoriness and the target, from the tens of bar of naphtha duty toward and beyond a hundred for hard gas oils and the hydrocracker boundary. Hydrogen purity in the recycle, set by makeup purity and purge losses, moves the same axis at fixed total pressure, which is why the purge stream and its recovery, and the makeup source's purity, are unit economics rather than details.
Temperature is the dial the operator spends. The unit starts a cycle at start-of-run temperature, the mildest condition that makes product, and raises weighted average bed temperature as catalyst deactivates, chasing the target until end-of-run temperature, set by reactor metallurgy, hydrogen consumption economics, or the turnaround calendar, says regenerate or replace. The temperature trajectory over the cycle is the unit's life story, and the buyer's guarantee should state it: target sulfur at start of run, the expected deactivation rate, and the end-of-run condition, because a unit that makes product only at a temperature it cannot sustain has been sold a sprint as a marathon.
Quench and redistribution manage the exotherm. Between catalyst beds, cold hydrogen, injected through quench nozzles, drops the gas-liquid mixture back toward the next bed's inlet design temperature, and redistribution baskets even the flow across the bed face so no lane runs hot; reactor internals, tray and distributor design, are the licensor's craft, because a maldistributed bed fouls and hot-spots locally while the average looks innocent. Bed thermometry, multiple points per bed, watches the profile, and a runaway, the runaway exotherm hydrotreaters are famous for, is the emergency the design and the procedures exist to prevent, quench at maximum, depressuring to the flare in the last resort.
The separation and stripping train turns reactor effluent into products. Heat exchange against feed recovers the exotherm's value; the high-pressure separator splits recycle gas from liquids at near-reactor pressure so the gas loops back to compression; lower-pressure separators flash successively lighter cuts; and the sour water formed, carrying ammonia and some hydrogen sulfide, draws to the sour-water stripper. The liquid product strips residual hydrogen sulfide and light ends in a stripper with a reboiler, and the sour gas from separators, stripper, and purge, hydrogen sulfide laden, goes to amine treating in a packed tower and on to the sulfur recovery unit. Every one of those neighbors has its own page; the hydrotreater's contract is to deliver to them.
Compression and control hold the loop together. The recycle compressor, centrifugal at large duties or a reciprocating compressor at small ones, runs continuously against the loop's pressure drop and is the unit's rotating heart, often spared, always watched; makeup hydrogen arrives on pressure control through metering and a control valve with a pressure transmitter supervision; and the unit's control scheme, feed and hydrogen ratios, temperature trajectory, separator levels, and stripper operation, is layered from basic regulatory control to the optimization that extends catalyst life. Instrumentation, bed thermocouples reading every bed, differential pressure across reactors, and analyzer loops on product sulfur, is the operator's sight, and the RFQ's control and analyzer scope should be explicit rather than inherited.
Chapter 3 / 06
Unit Types, Feed Duties, and Machine Boundaries
Feed duties name the unit classes. Naphtha hydrotreaters run the gentlest duty, moderate pressure and temperature, cobalt-moly catalyst, tight sulfur for reformer protection, and small units. Distillate hydrotreaters span the ULSD era's engineering, higher pressure, graded catalysts with hydrogenation strength, and sophisticated stripping to make ten parts per million on cracked stocks. Gas oil hydrotreaters pretreat conversion feed at severity set by the downstream unit's tolerance. Resid and specialty hydrotreaters, and the once-through or recycle configurations that distinguish treating from conversion, run at the top of the severity range; the hydrocracker beyond this page's boundary takes the same hardware to higher pressure and full conversion intent.
Reactor architecture separates offerings modestly and honestly. Single-reactor designs with multiple beds serve most duties; two-reactor trains in series add flexibility for grading and expansion; and swing reactors, a spare in the lineup that alternates with a working one, buy continuous operation through catalyst change at the cost of a vessel. Radial-flow and other specialty reactors serve vapor-phase naphtha duty. The differences that matter commercially are reactor volume per barrel, the internals' distribution quality, and the quench system's authority, all of which the licensor's reference list and cycle projections speak to better than the brochure.
Catalyst systems are the unit's consumable identity. A modern charge grades from demetallization and scale-catcher material at the top, through transition catalysts, to the main hydrogenation and desulfurization beds sized for the cycle; catalyst vendors, Albemarle, ART, Haldor Topsoe, and their peers among them, sell the system as a designed charge, and the unit's license and its catalyst often come from different houses. Cycle length targets align with the refinery turnaround calendar, two to four years common in fuels service, and spent catalyst leaves for regeneration or metals reclaim, its disposal a regulated path the purchase should anticipate.
Adjacent machines mark the boundary. The hydrotreater is not the hydrocracker, which converts as it treats and keeps its own page; not the steam methane reformer or hydrogen electrolyzer that supply its makeup hydrogen, only their customer; and not the amine unit, packed tower, and sulfur recovery unit that take its sour gas, though the sour-gas interface defines its environmental contract. Its feed front door touches the crude unit and the electrostatic desalter upstream of that; its product back door touches blenders, the FCC or the reformer it protects, and the delayed coker whose naphtha it may treat. Its sour water goes to the sour-water stripper, its vents to the flare-stack, its heavy purge gas to fuel or recovery, and its fired heater shares the refinery's furnace practice; each neighbor keeps its own leaf in this encyclopedia.
Utilities and offsites complete the installed unit. The fired heater, sharing fired-equipment practice with the refinery's other heaters; the heat exchanger train, typically shell-and-tube networks running at high pressure; the separators and drums of the flash train, the knockout-drum family; the stripper with its reboiler; the compressors and their seals; high-pressure letdown valves; and the water systems, sour water to stripping, cooling through the site's cooling tower network on condensers. A small centrifugal pump lineup moves feeds, products, and amine at the boundaries, with feed pumps commonly on variable frequency drives for turn-down and start-up discipline; a coalescing filter polishes sour gas or product where the flash train's carryover demands it; the refinery's steam boiler house supplies stripping and tracing steam; instrumentation and analyzers close the control loops; and emergency systems, depressuring to flare, quench at maximum, and safety-relief protection on every pressure stage, are code-given and license-given rather than optional. Stripped sour water and contaminated condensate route to the wastewater plant, where an induced gas flotation train lifts residual oil before discharge or reuse.
Chapter 4 / 06
Key Specification Parameters
The vendor data sheet for a hydrotreater centers on feed, severity, hydrogen, and cycle, and each number carries a duty consequence. The table below lists the parameters that recur across licensors' offerings for the fuel-duty classes, with typical ranges a buyer will see. Values for a specific project come from the feed's assay and pilot data and the product target, and the ranges here are orientation, not a substitute for that engineering.
Parameter
Typical catalog range
What it decides
Feed throughput
unit specific, thousands of BPD
Reactor volume; heater and compressor sizing
Reactor pressure
30 to 100+ bar by duty
Severity; wall thickness; cycle life bought
Weighted average bed temperature
roughly 320 to 400 C by duty
Reaction rate; deactivation spending
Hydrogen partial pressure
set by total and purity
Equilibrium toward target; coking suppression
Hydrogen consumption
tens to hundreds of scf/bbl
Operating cost; makeup supply sizing
Hydrogen-to-oil ratio, recycle
several hundred scf/bbl
Bed quench authority; vapor-liquid behavior
Liquid hourly space velocity
roughly 1 to 4 per h
Reactor volume per barrel; severity trade
Product sulfur
target specific, ULSD at 10 ppm
Severity and catalyst system requirement
Cycle length
12 to 48 months by duty
Turnaround fit; catalyst economics
Catalyst volume and grading
designed charge per feed
Metals tolerance; cycle and activity
Three of these numbers deserve the buyer's suspicion when they arrive without a basis. Cycle length quoted without the feed's contaminants and the end-of-run temperature basis is a wish. Hydrogen consumption quoted without the saturation extent assumed hides the operating cost the refinery will actually pay. Product sulfur quoted at start-of-run conditions alone ignores the deactivation that owns most of the cycle. An RFQ that demands the temperature trajectory and the pilot or commercial basis behind it separates engineered offers from assembled ones.
Materials and construction follow the severity. Reactors are heavy-wall chrome-moly steel with stainless or clad internals operating in hydrogen service under the industry's hydrogen-attack provisions; exchangers and heaters in the hot loop share the metallurgy discipline; compressors are hydrogen-service machines with their seal and material specifications; and letdown, sampling, and relief hardware round out the high-pressure battery. Every reactor carries coded relief protection, safety relief valves staged to flare, and the unit's depressuring system, and its inspection regime follows pressure-equipment practice for hydrogen service throughout its life.
Chapter 5 / 06
Selection Decision Factors and RFQ Language
Selection starts with the feed and the target, not the catalog. The feed assay, boiling range, sulfur species and total, nitrogen, metals, and contaminants like silicon or chloride, together with the product specification, decide the severity class, the catalyst system, and the hydrogen consumption; pilot testing on the actual feed, or commercial data on its twin, is the honest basis of any guarantee, and a licensor without either should quote correlations with humility rather than guarantees with confidence. The hydrogen balance across the refinery, makeup supply, purity, and price, frames the operating economics before any reactor is sized.
The cycle and turnaround decision shapes the whole unit. Cycle length matched to the refinery's turnaround calendar buys scheduling peace; longer cycles bought with pressure and catalyst volume cost capital; swing reactors buy continuity at vessel cost; and regeneration logistics, off-site regen or replacement, price the catalyst rhythm. Severity allocation between pressure, catalyst volume, and temperature trajectory is the licensor's core optimization, and the buyer should demand the end-of-run condition and deactivation rate behind every offer's cycle number, because that is the number the refinery lives with between turnarounds.
The table below organizes the decision into the factors that recur across projects, with the questions the buyer should be able to answer before the RFQ goes out. Each row is a place where an incomplete answer becomes an underspecified unit and a sulfur excursion or shortened cycle later.
Decision factor
What the buyer must state
Consequence if left open
Feed and assay
Cut, rate, sulfur and nitrogen species, metals, contaminants
Catalyst and severity guessed; guarantee is void
Product target
Sulfur, nitrogen, and saturation spec; downstream basis
Under-bought severity; product misses at EOR
Hydrogen supply
Makeup source, purity, pressure, availability
Loop purity and compressor sizing wrong
Severity and cycle
Pressure class, cycle length fit to turnarounds, EOR basis
Capital and catalyst rhythm mismatched
Catalyst system
Grading intent, regeneration or replacement path
Metals kill beds early; disposal argument late
Sour-gas interfaces
Amine capacity, SRU capacity, sour water handling
Downstream bottleneck discovered at startup
Utilities and plot
Heater fuel, cooling, HP equipment plot, expansion
Layout and offsite disputes late
RFQ language for a hydrotreater should name the feed and the trajectory. A workable specification states: feed source and assay with sulfur species, nitrogen, metals, and contaminants, design and maximum rate; product specifications including sulfur at end-of-run conditions, and any downstream protection basis; hydrogen makeup source, purity, and pressure with consumption expectations; reactor pressure class and severity intent with vendor free to propose; catalyst system grading and cycle length with start-of-run and end-of-run temperatures and deactivation basis; recycle compressor and makeup interface scope; fired heater and exchanger train scope with metallurgy expectations; separator train, stripper, and sour-gas delivery interfaces to amine and sulfur recovery; sour-water routing; instrumentation, analyzers, and the emergency depressuring and quench philosophy; and the acceptance basis, feed run against the trajectory with product sulfur witnessed at SOR and projected through the cycle. Naming the interface equipment, the steam methane reformer or hydrogen electrolyzer on makeup, the amine unit on sour gas, lets vendors bid the connections correctly.
Chapter 6 / 06
Installation, Standards, Failure Modes, and Maintenance
Installation is heavy-vessel and hydrogen-discipline work. Reactors arrive as shop-fabricated heavy-wall vessels and set into foundations with the exchanger train, heater, and compressor around them; high-pressure piping welds under full code inspection; and commissioning follows a strict sequence: drying and inerting, catalyst loading by dense or sock methods with the distributor checks that protect the bed, sulfiding the catalyst under controlled chemistry, then feed introduction at reduced rate with temperature raised along the licensor's curve to start of run. Performance acceptance runs the feed at rate against the product target, and the first weeks of operation calibrate the trajectory the cycle will follow.
Standards for hydrotreaters are pressure-equipment and refining practice rather than a single machine standard. Reactors and high-pressure systems follow the pressure equipment code of the jurisdiction with hydrogen-service provisions; fired heaters follow refinery furnace practice; compressors follow rotating machinery specifications; and the process safety framework, relief to flare, depressuring, and safeguarding studies, follows the site's process-safety regime under the major-hazard regulations that apply. There is no single international hydrotreater standard governing the unit end to end, so the RFQ must name the applicable pressure, mechanical, and safety codes and the licensor's own design standards for reactors and internals. Edition references should be verified current at purchase rather than copied from an old specification.
The recurring failure modes concentrate in catalyst, distribution, and the hydrogen loop. Catalyst deactivation beyond design, from metals in the feed or a feed slip, shows as temperature trajectory steepening and cycle shortening; fouling and pressure-drop buildup in the first beds, from feed particulates or coke, show as reactor differential and shortened runs, fought by grading and feed filtration; maldistribution hot spots hide from average thermometry until they do not, which is why bed temperature profiling is the operator's constant read; and loop leaks or compressor trips drop hydrogen partial pressure with the severity that follows. Runaways are the catastrophic mode the emergency systems and operator training exist for, and their drills are maintenance in the fullest sense.
Maintenance planning is turnaround-shaped with continuous care between. The table below lists the recurring items with the typical cadence a plant will schedule, assembled from common practice; the real schedule follows the cycle's trajectory and the inspection code's intervals for the pressure systems.
Item
Typical action
Typical cadence
Bed temperatures and profile
Trend WABT and bed deltas; log deactivation rate
Continuous
Reactor differential pressure
Trend; investigate rise; screening at outage
Continuous to weekly
Product sulfur analyzer
Calibrate and verify against lab
Weekly to monthly
Compressors
Vibration, seal and oil systems, performance check
Continuous monitoring, quarterly survey
Heater and exchangers
Tube inspection, fouling and skin temperature review
Each turnaround
Catalyst
Skim or replace guard at turnaround; regenerate or replace main per cycle
Turnaround cycle
Relief and depressuring systems
Proof test valves, verify flare path
Annual to code schedule
Long-term care keeps the trajectory honest as the refinery drifts. Feed slates change with crude economics, and the unit tuned for one slate deactivates faster on another; periodic feed assay review against the catalyst's design basis, hydrogen balance optimization, and catalyst vendor re-projection extend cycles that drifting quietly shortens. Internals and distribution upgrades pay back on existing reactors, and next-generation catalysts drop into old hardware for tighter targets. The plant that treats the hydrotreater as a trajectory-managed asset, read weekly and re-projected yearly, is the plant whose diesel pool never meets a sulfur surprise.
FAQ
What does a hydrotreater remove and how?
It removes sulfur, nitrogen, oxygen, and metals from hydrocarbon streams by reacting them with hydrogen over a fixed bed of sulfided cobalt-molybdenum or nickel-molybdenum catalyst. Sulfur compounds hydrogenolyze to hydrogen sulfide, nitrogen becomes ammonia, oxygen becomes water, and metals deposit on guard catalyst designed to absorb them; the treated liquid then strips light ends and residual sulfur species. The reactions are exothermic, the reactor runs as a trickle bed of liquid and gas over catalyst, and the sour streams leaving the unit, sour gas and sour water, go to amine treating and stripping before sulfur recovery.
What is the difference between a hydrotreater and a hydrocracker?
Severity and intent. A hydrotreater treats: it removes contaminants with minimal change to the boiling range, running at moderate pressure with the target a clean, intact stream, ULSD or reformer feed. A hydrocracker converts: higher pressure, bifunctional cracking-plus-hydrogenation catalyst, and a product slate shifted aggressively toward lighter, more valuable molecules. The hydrotreater's hardware, reactors, hydrogen loop, and separation, is the hydrocracker's ancestor, but the units are bought for different jobs, and this encyclopedia keeps the hydrocracker as its own topic rather than a hydrotreater variant.
Why does hydrogen pressure matter so much in hydrotreating?
Because hydrogen partial pressure buys severity three ways at once. Thermodynamically it pushes the desulfurization and denitrogenation reactions toward completion, especially the refractory sterically hindered species that ULSD duty must convert; kinetically it suppresses the coking and condensation reactions that deactivate catalyst; and practically it sets how far the unit can raise temperature, spend its deactivation, before the cycle ends. Pressure costs capital in reactor walls and operating in compression, so the design's pressure class is the central severity purchase, set by the feed's refractoriness and the cycle length the refinery wants.
What is catalyst cycle length and how is it determined?
The time between catalyst loadings, defined by when the unit can no longer make product at its allowed temperature. A charge starts at start-of-run temperature, the mildest condition meeting target, and deactivates as metals deposit and coke accumulates, forcing the operator to raise weighted average bed temperature; when the trajectory approaches the end-of-run limit, reactor metallurgy, hydrogen consumption economics, or the turnaround calendar, the cycle ends in regeneration or replacement. Cycle length is set at design by pressure, catalyst volume and grading, and the feed's contaminants, and the buyer's guarantee should state SOR and EOR temperatures and the deactivation rate, not a single number without its basis.
What are quench hydrogen and reactor internals for?
For managing the exotherm and the flow. Hydrotreating releases heat, and between catalyst beds, cold hydrogen injected through quench nozzles brings the gas-liquid mixture back down to the next bed's design inlet temperature; without it, bed temperatures would cascade upward into runaway territory. Redistribution internals spread the mixed flow evenly across the bed face, because a maldistributed bed runs lanes hot and cokes locally while average readings look normal, and bed thermometry watches the profile. Quench authority and distributor quality are licensor craft, and honest RFQs ask about both.
Where does the hydrogen sulfide from a hydrotreater go?
To the refinery's sulfur chain. The hydrogen sulfide formed in the reactors leaves with the separator gas and stripper overheads as sour gas, which an amine unit scrubs in a packed tower contactor, removing the acid gas; the amine regenerates and the acid gas feeds the sulfur recovery unit, which converts the hydrogen sulfide to elemental sulfur for sale or disposal. Sour water carrying ammonia goes to the sour-water stripper, and vents and upsets route to the flare-stack. The hydrotreater's environmental contract is written at these interfaces, which is why the RFQ should state the sour-gas and sour-water delivery terms explicitly.
What should a hydrotreater RFQ include?
State the feed source and assay with sulfur species, nitrogen, metals, and contaminants at design and maximum rate; product specifications including sulfur at end-of-run, with the downstream protection basis; hydrogen makeup source, purity, and pressure; reactor pressure class and severity intent with vendor free to propose; the catalyst system grading with cycle length, start-of-run and end-of-run temperatures, and the deactivation basis; recycle and makeup compression scope; fired heater and exchanger metallurgy expectations; separator train and stripper scope with sour-gas and sour-water delivery interfaces; instrumentation, analyzers, and the depressuring and quench philosophy; and the acceptance basis, a feed run at rate against the trajectory with product sulfur witnessed. Naming the makeup hydrogen supplier, the amine unit, and the sulfur recovery unit as interfaces lets licensors bid the connections correctly.