A visbreaker is the refinery's gentlest conversion unit, and the only one whose first aim is to make a residue flow more easily rather than to take it apart. Atmospheric or vacuum residue is pumped through a fired furnace, held at cracking temperature for seconds or for many minutes depending on the design, quenched, and flashed. The heat breaks enough of the large molecules to thin the tar and to make some gas, naphtha, and gas oil. The unit itself is a furnace with a carefully controlled soaking zone, a quench, a fractionator, and often a vacuum flasher; licensors count on a conversion of ten to fifty percent of the feed to gas, gasoline, and distillate, and this page treats the whole train as the purchasing object.
The job of specifying one begins with the residue assay and the fuel oil the refinery must blend. N-pentane insolubles, softening point, asphaltenes, Conradson carbon, and sodium in the feed decide how far the cracking can go and how fast the furnace tubes coke; sodium is on the list because the crude unit's desalter, not the visbreaker, controls it. From there the choices narrow to coil or soaker, to the conversion and viscosity the unit is guaranteed to reach, and to the run length expected between decokings. The chapters below follow that order. Figures quoted from a source are marked by it; the rest are the ranges a buyer will meet in offers, not design values for a particular unit.
Four decisions carry most of the purchase of a visbreaker: the feed assay, since a residue rich in asphaltenes, Conradson carbon, or sodium limits conversion and shortens furnace runs; the coil or soaker choice, which trades furnace temperature against drum residence; the conversion and viscosity target, which must stop short of the point where the fuel oil becomes unstable; and the furnace, its duty, alloy tubes, flux profile, pass control, and run length, where the unit's availability and its main hazard live.
Chapter 1 / 06
What a Visbreaker Is and What Is Being Decided
Stripped to its equipment, a visbreaker is a furnace with a separation train behind it. Residue from the atmospheric or the vacuum tower passes through a feed and effluent heat exchanger train, then through furnace coils that raise it to cracking temperature while steam injected at several points keeps the oil moving fast. In a coil design the cracking is finished as the oil leaves the coils; in a soaker design it is finished in an insulated drum downstream. A quench of cool gas oil stops the reaction, and the mixture flashes into a fractionator that splits it into gas and naphtha overhead, a steam stripped gas oil side draw, and visbroken tar from the bottom.
The problem it solves is a residue nobody can move. Vacuum residue from a heavy crude is commonly a tar in the thousands of square millimetres per second at fifty degrees Celsius (122 degrees Fahrenheit) as it leaves the vacuum tower, too thick to burn in a boiler or a marine engine. The classic remedy was to dilute it with gas oil, called cutter stock, until it met the viscosity of a standard heavy fuel grade. That cutter stock is gas oil that could be diesel or cracker feed. Visbreaking thins the residue with heat instead, so the refinery needs less cutter stock to meet fuel oil specifications and, depending on the sulfur limits it must meet, can cut its fuel oil production by about twenty percent while making gas, naphtha, and distillate from the difference.
What is being decided when a visbreaker is bought is a conversion and viscosity guarantee that has to hold without the furnace coking up early or the fuel oil sludging in a customer's tank. The buyer states the residue, its rate, and the fuel oil grade to be made, and asks for the tar viscosity, the yields, and the heater run length. Furnace duty, coil volume, soaker volume, flux rate, quench temperature, and fractionator tray count all follow from it. The guarantee sits near a cliff: a little more conversion than the feed allows turns stable fuel oil into sediment before the fuel ever reaches a customer's burner.
Visbreaking is the shallowest of the routes a refinery has for its bottom of the barrel, and the cheapest, because it uses heat alone. Take the same residue a stage further with heat and it makes solid coke, which is delayed coking, a separate unit with drums, switching, and coke handling that this encyclopedia describes on its own page. Treat it with hydrogen under pressure instead and a residue hydrotreater removes sulfur and metals while leaving it liquid, at the cost of hydrogen and catalyst. A visbreaker converts less than a coker and asks for less than a hydrotreater: no hydrogen, no catalyst, no drums to cut, and a furnace as its main piece of steel.
Refineries buy the unit for different barrels. One with a surplus of residual fuel and a marine fuel market buys it to hold the viscosity grade with less cutter stock. One that wants more gas oil for its fluid catalytic cracker or its distillate pool buys it for the distillate and for the vacuum gas oil a flasher can recover from the tar. One with an asphalt business is careful, because visbreaking changes the properties of the residue as a binder. And one fighting a drift toward heavier crude slates uses the visbreaker to keep the fuel oil balance from tipping, since the heavier the crude, the more vacuum residue each barrel leaves behind.
The value statement is simple to write and sensitive to two prices. The unit takes the cheapest barrel in the refinery and turns part of it into naphtha and gas oil worth more, while leaving the rest easier to sell; licensors describe a conversion to gas, gasoline, and distillates of ten to fifty percent, feed and severity depending. Against that stand furnace fuel, a small power and steam balance, and the upkeep of a heater that runs hot on purpose. The two prices that swing the case are the gap between residual fuel and distillate and the cost of the cutter stock the unit saves. When that gap is narrow the visbreaker still pays as the cheapest way to keep residue pumpable.
Chapter 2 / 06
How Furnace, Soaker, and Fractionator Do the Work
The chemistry is thermal cracking without a catalyst. Above roughly four hundred degrees Celsius the heat breaks carbon to carbon bonds in the large molecules of the residue, starting with the heavy oils that carry long paraffin chains. Each break leaves fragments called free radicals, which take hydrogen from neighbors or split again, and the smaller molecules that result boil lower and flow more easily. The asphaltenes, the heaviest and most aromatic fraction, pass through the furnace almost unchanged at moderate severity. They stay dissolved because the surrounding oils act as a solvent; crack too much of that solvent away and they come out of solution as sediment.
The furnace is where a visbreaker succeeds or fails, and where it can hurt people. Residue coke forms wherever oil sits hot against tube metal, so the heater is designed around velocity and evenness: high in-tube velocity to raise the inside heat transfer coefficient and keep the tube wall cool, a flux rate spread evenly over the tubes, symmetrical coil and piping layouts, and individual pass control with several steam injection points per pass so that no pass runs slower or hotter than the others. EPA's emission factors list furnace conditions of 455 to 480 degrees Celsius (850 to 900 degrees Fahrenheit) at 3.4 to 17.2 bar (50 to 250 psig), with the residence time, temperature, and pressure of the soaking zone controlled to set the conversion.
Conversion is a product of temperature and time, and the two designs spend those differently. A coil visbreaker runs a hotter furnace outlet and gives the oil only the seconds or minutes it spends in the last passes of the coil. A soaker visbreaker runs a lower outlet temperature and lets the two-phase effluent soak in a drum on a plug flow basis for many minutes, with most of the conversion happening outside the furnace. At a given severity, licensors report that the two give the same product qualities and yields. Severity, the combination of the two, is the single number that decides how much distillate the unit makes and how close it runs to unstable fuel oil.
Leaving the coil or the soaker, the hot effluent is quenched at once, with gas oil in EPA's description, because the cracking would otherwise continue in the transfer line and the fractionator and lay coke there. The quenched stream flashes into the fractionator. Overhead vapor condenses into a sour gas and a naphtha that is unsaturated and needs treating before it is gasoline. A gas oil drawn from the middle of the tower is stripped with steam; it may be recombined with the tar for heavy fuel oil, as in the classic flowsheet, or kept apart for hydrotreating. The bottoms are visbroken tar, still hot and thin enough to pump, on their way to blending or to further processing.
More gas oil can be taken from the tar if the refinery wants it. A vacuum flasher downstream of the fractionator distills a vacuum gas oil out of the visbroken tar under a vacuum held by steam ejectors, leaving a heavier pitch for fuel oil. The vacuum gas oil is good feed for a fluid catalytic cracker because visbreaking has already broken some of its large molecules. One licensor also offers recovering a high share of that gas oil in the fractionator of a coil unit, without a separate flasher. Whether the flasher is built is a selection decision: it adds a tower and a set of ejectors, and it removes distillate from the fuel oil pool.
Heat recovery is where a simple unit earns its efficiency. Feed passes through a shell-and-tube heat exchanger train against hot tar and gas oil before it reaches the furnace, and the furnace's convection section raises steam. The licensors note that a soaker's lower heater outlet temperature may lower fuel cost but also reduces that steam production, so the steam balance belongs in the comparison between the designs. The overhead system condenses and separates naphtha and sour water, the sour gas goes to the gas plant, and quench and strip steam leave through the fractionator overhead. Because the furnace burns fuel around the clock, its excess air and flue gas heat are metered as closely as the reaction.
Chapter 3 / 06
Coil and Soaker Types and Machine Boundaries
In a coil visbreaker, sometimes called a furnace visbreaker, nearly all of the conversion happens in a dedicated cracking coil at the hot end of the furnace. The outlet temperature is the severity lever and the residence time is whatever the coil holds. The reward is mechanical simplicity: no soaker drum, less hot high-pressure volume, and, because the coking coil is a small well defined part of the furnace, it can be cleaned on line without stopping the unit. Small units do this with a two-cell furnace taking one cell off line in turn; larger units take one heater off line at a time. The licensors behind the UOP and Foster Wheeler USA offering state a preference for this design.
In a soaker visbreaker the furnace brings the oil part of the way and a soaker drum finishes the job. The drum is a vertical vessel sized to hold the two-phase effluent at an elevated temperature for a predetermined residence time, the flow through it approaching plug flow so that no part of the oil is over-cracked. Its heater outlet temperature is lower, which in practice slows the coking rate in the tubes and lengthens the intervals between furnace decokings. The costs are a large hot vessel that gathers coke over several years and must itself be cleaned out at a turnaround, more steel in the reaction section, and a lower steam yield from the furnace's convection section.
Two further labels describe what surrounds the reaction section rather than the reaction itself. A once-through visbreaker takes residue, cracks it, and sends tar to fuel oil blending with only the fractionator's own separation; a visbreaker with a vacuum flasher adds the vacuum step that pulls gas oil out of the tar and leaves pitch. Units are also described by severity: a low severity unit is run to hold a fuel oil viscosity grade with the longest furnace runs, and a high severity unit is pushed for distillate, and either furnace type can be built at either level. The gas oil can be recombined with the tar for fuel oil or drawn off, which turns the same hardware into two different yield slates.
The boundary that matters most runs between this unit and delayed coking, and this page is where that line is drawn. Visbreaking is the milder thermal step: it is run for a viscosity reduction and a modest distillate yield, and it stops short of the conditions at which the residue would leave solid coke behind. A delayed coker runs the same kind of chemistry further, on purpose, until coke forms in drums that must be opened and cut. The coker page of this encyclopedia covers that unit and only points to visbreaking; the furnace, fractionator, and flasher of a visbreaker are specified here. The visbreaker is also not the fired heater it contains, which shares the practice of refinery fired equipment and has its own page, nor the electrostatic desalter far upstream in the crude train.
The unit's connections explain its place in a refinery. Feed comes from the vacuum or atmospheric tower of the crude unit, downstream of the electrostatic desalter, and desalting matters here: sodium in the residue speeds coking in furnace tubes, and minimizing it lengthens operating cycles significantly. Naphtha and gas oil go to a hydrotreater, where a cracked stock is cleaned up, and vacuum gas oil goes to the fluid catalytic cracker. Tar goes to fuel oil blending, to a residue hydrotreater, or to storage through lines fitted with heat tracing cable because it sets when cold. Sour gas goes to an amine unit and on to a sulfur recovery unit, sour water goes to a sour water stripper, cracked gas adds a little olefin to an alkylation unit, and safety relief valves and rupture disks discharge to a knockout drum and a flare stack.
Chapter 4 / 06
Key Specification Parameters
A visbreaker data sheet is short, and most of its lines describe the furnace; a short data sheet is not a simple one, because each line hides a choice described below. The table gives heater outlet temperature and pressure, residence time, conversion, the change in fuel oil output, tar viscosity, typical yields, run length, and tube wall temperature. The heater conditions are the EPA emission factors' figures and the conversion and fuel oil figures are the licensors' from the UOP and Foster Wheeler USA datasheet; residence times, yields by weight, run length, soaker cleaning, and the tube wall limit are stated as practice usually finds them. At the guarantee stage the buyer's own residue assay governs every row.
The parameter that governs the rest is fuel oil stability. Licensors' data show that as severity rises the viscosity of the tar, the fraction boiling above 204 degrees Celsius (400 degrees Fahrenheit), first falls and then rises steeply; that reversal marks the point beyond which the fuel oil may become unstable. Stability, not furnace capability, limits the conversion a feed will allow. A residue with a high asphaltene content tolerates less conversion, because it holds less crackable oil to keep the asphaltenes dissolved. On a data sheet the operating point should sit at the lowest viscosity that still leaves a margin above the minimum acceptable stability, and the acceptance test should measure sediment as well as viscosity.
Materials follow temperature and coke. Furnace tubes in the hot passes are chromium-molybdenum alloys chosen for oxidation and creep at tube wall temperatures far above the oil temperature, with the cooler passes in lower alloys or carbon steel; the transfer line, soaker, and fractionator bottoms follow the same grading downward. Tube wall temperature is the limit that ends a run: as coke thickens inside a tube the wall runs hotter for the same oil temperature until the creep or oxidation limit is reached. Coke fines spalled from the tubes travel with the effluent and erode pump internals, valve trim, and exchanger tubes, so hardened trim and wear resistant fittings are specified in the tar circuit.
Parameter
Typical catalog range
What it decides
Feed
atmospheric or vacuum residue
Conversion allowed; coking rate
Heater outlet temperature
455 to 480 C (850 to 900 F)
Conversion; tube coking; run length
Heater outlet pressure
3.4 to 17.2 bar g (50 to 250 psig)
Vaporization in the coil; flash zone
Residence time, coil
typically seconds to a few minutes
Coil volume; outlet temperature
Residence time, soaker drum
commonly 10 to 20 min
Soaker volume; heater outlet
Conversion to gas, gasoline, distillate
10 to 50 percent of feed
Distillate yield; fuel oil output
Fuel oil production
can fall by about 20 percent
Cutter stock saved; sulfur limits
Tar viscosity
lowest above minimum stability
Cutter stock needed; fuel grade
Yields by weight, typical
gas 2 to 3, naphtha 5 to 8, gas oil 10 to 15, tar 75 to 80 percent
Distillate and fuel balances
Heater run length
commonly a year or more between decokes
On-stream factor; decoke plan
Soaker coke removal
usually at turnaround intervals
Drum volume; outage length
Tube wall temperature
held under the alloy limit
Run length; tube life
Chapter 5 / 06
Selection Decision Factors and RFQ Language
Selection starts with the assay, because the residue decides how much the unit can do. Licensors rank feeds by n-pentane insolubles and softening point: residues low in both respond well, residues high in both respond poorly. Asphaltenes and Conradson carbon cap the conversion that keeps the fuel oil stable, and Conradson carbon and sodium together set how fast the furnace tubes coke. A buyer should have the full assay, sodium included, before asking for a guarantee, and should expect the licensor to run pilot work or to quote units on a similar residue. A feed that drifts toward heavier or dirtier crude after start-up is the commonest reason a visbreaker stops making its numbers.
The coil or soaker choice comes next, and it is about where to put the time. A buyer who picks a coil unit accepts a hotter furnace outlet and a furnace that must be able to clean a pass while the rest keeps running, and in exchange gets the simplest reaction section: no soaker drum, no drum to open and clean. A buyer who picks a soaker unit accepts a large hot drum and its periodic cleaning in exchange for a cooler furnace, a lower fuel bill, typically slower tube coking and longer intervals between furnace decokings, giving up some steam production. Yields are the same at equal severity, so the decision rests on the refinery's furnace practice, its turnaround pattern, and its comfort with a vessel full of hot oil.
The conversion and viscosity target has to be written as a point with a margin. The refinery names the fuel grade it must blend, the cutter stock it has, and the pour point it needs in the blended residual fuel, and the licensor finds the severity that reaches them. Pushing severity raises distillate yield and lowers tar viscosity only up to the reversal point; past it, asphaltenes precipitate, and the fuel oil forms sediment in storage and sludge that plugs filters. A refinery that wants more conversion than stability allows should be buying a delayed coker, not a harder run visbreaker. Commercial terms pair a tar viscosity with a stability limit. Where the refinery has a residue hydrotreater, the target may instead be a tar that hydrotreats well rather than one that blends.
Heater duty and run length are bought together. The duty follows the conversion target and the heat recovery; the run length follows the duty, the flux profile, the pass control, and the sodium in the feed. The buyer should state the minimum run length between decokings and the on-stream factor expected rather than leave both to the licensor. On-line decoking or spalling, two-cell furnaces, and multiple steam injection points per pass are the features that make a long run possible, and each has a price. A guarantee tested at the end of a full run says more than one tested in its first week, so the performance test should be scheduled accordingly.
Downstream disposition closes the decision. Keeping the gas oil with the tar maximizes fuel oil and minimizes treating; drawing it off and hydrotreating it makes distillate; adding a vacuum flasher makes more fluid catalytic cracker feed and leaves a pitch that may be harder to sell. Each route moves the unit's value with the prices of fuel oil, distillate, and gas oil, and the buyer should ask for the yields under each. The plot, the heat exchanger train, and the tar pumps, heavy-duty centrifugal pump machines, are sized for the heaviest case. Beyond the battery limits, the amine unit, the sulfur recovery unit, and the hydrotreaters must have room for what the visbreaker sends them.
The nine rows below pair each visbreaker decision with what the buyer has to state and with the cost of leaving it blank. A residue assay without sodium, a fuel oil target without a stability limit, or a run length without a decoke plan comes back as a furnace shutdown, a sludging fuel, or a guarantee with no basis.
Grade, cutter stock, tar viscosity, pour point, stability limit
Cutter stock saved overstated; fuel sludges
Coil or soaker
Preferred reaction section; tolerance for a soaker drum
Furnace and plot designed for the wrong scheme
Furnace
Duty, flux and tube wall limits, pass control, steam injection
Short runs; tube damage
Run length
Minimum months between decokings; on-stream factor
Availability promised without a basis
Decoking method
On-line cleaning or shutdown cleaning; furnace cell arrangement
Unit stops for every decoke
Fractionator and flasher
Side draws, distillate disposition, vacuum flasher or none
Yields fixed by hardware; resale hard
Downstream units
Treating capacity for naphtha, gas oil, gas, and tar
Bottlenecks found at full rate
Heat recovery
Exchanger train scope, steam production, air preheater
Fuel bill above the study estimate
A visbreaker RFQ has to name the residue and the point on the severity curve before it names equipment. A bid-ready specification states: the residual feed assay, with source, rate, Conradson carbon, asphaltenes, n-pentane insolubles, softening point, sodium, and sulfur; the target viscosity or conversion, meaning the fuel oil grade to be blended, the cutter stock available, the tar viscosity and pour point expected, and the sediment or stability limit to be met; the coil or soaker intent, with the reaction section arrangement open to the bidder where that is acceptable; the heater duty and run-length constraints, including minimum months between decokings, the decoking method, the flux and tube wall temperature limits, and the on-stream factor; the fractionator scheme, the vacuum flasher if any, and where naphtha, gas oil, gas, and tar go; utilities at the battery limit; and the acceptance basis, a performance test on the stated residue measuring tar viscosity, stability, yields, and furnace pressure drop.
Chapter 6 / 06
Installation, Standards, Failure Modes, and Maintenance
Installation is heater and hot-oil work. The furnace builds in refinery fired-equipment practice with its stack, air preheater, and sootblowers; the soaker, where there is one, sets beside it; the fractionator and any flasher tower rise over the heat exchanger train, whose shells are arranged so that bundles can be pulled in a fouling service. Transfer lines are short and made of chromium-molybdenum steel. Tar lines from the fractionator to storage or blending are insulated and traced, because visbroken tar that cools in a line sets into a plug that has to be dug out. Commissioning circulates clean oil, dries the refractory, brings the furnace up pass by pass, and introduces residue only when the quench and the fractionator are proven.
Standards for a visbreaker are the pressure, piping, and fired-equipment standards of the refining industry rather than one machine standard. Vessels and the soaker follow the jurisdiction's pressure equipment code, the ASME Boiler and Pressure Vessel Code in the United States, and piping follows ASME B31.3. The furnace follows API 560, the fired heater standard, with tube thickness calculated by API 530, and its burners, fuel system, and safety instrumentation follow the fired heater practice described on that page of this encyclopedia. In-service inspection follows API 510 for vessels and API 570 for piping. The RFQ should name the editions current at purchase rather than copy them from an older document.
The recurring failure modes begin in the furnace. Coke thickening in a tube raises the tube wall temperature and the pressure drop across the pass until the pass must be cleaned or the tube is at risk of rupture, the unit's most serious event. A failed quench lets cracking continue in the transfer line and the fractionator, where coke builds in the bottoms and on the trays. Coke fines carried from the tubes erode tar pump internals, control valve trim, and exchanger tubes, and settle in the bottoms system. In the overhead, sour naphtha and hydrogen sulfide corrode carbon steel wherever water condenses. And a unit run past its stability point makes fuel oil that sludges in a customer's tank.
Operators watch a handful of readings. A thermocouple on the skin of each tube and a temperature transmitter at each pass outlet show the wall temperature creep that means coke. A differential pressure transmitter across each coil and a flow meter on each pass show the restriction as it forms, and a pressure transmitter at the furnace outlet and a level transmitter on the fractionator bottoms finish the set. A zirconia oxygen analyzer on the flue gas holds the furnace's excess air, and a sootblower keeps the convection section clean. In the laboratory, the tar's viscosity and a spot test for sediment on the blended fuel oil tell whether the unit is still inside its stability margin. The trends of these readings, not their values, schedule the next decoking.
On a visbreaker the maintenance calendar is set by the furnace: tube skin temperatures and pass pressure drops say when a coil must be cleaned, and the rest waits for a turnaround. The cadence column is what practice usually sees. The repair made most often between runs, steam-air decoking of a pass, runs in this order:
Take the pass off line, isolate it, and strip the oil out with steam.
Heat the pass with steam to coke burning temperature, then admit air in small steps.
Follow the burning front down the coil by the carbon dioxide in the exit gas and by tube skin temperatures, keeping the wall below its limit.
Alternate steam and air until the exit gas shows that the coke is gone.
Cool the pass, purge it, and return it to service.
Item
Typical action
Typical cadence
Tube wall temperature
Trend skin thermocouples pass by pass; note the climb rate
Continuous
Coil pressure drop
Compare each pass against its clean baseline
Daily to weekly
Decoking
Steam-air decoke or on-line spall when wall temperature or pressure drop reaches its limit
Once or more per run
Sootblowing
Clean the convection section; track flue gas temperature
Daily per practice
Quench and transfer line
Verify quench flow; inspect for coke at every opening
Continuous check, turnaround inspection
Fractionator
Remove coke fines; inspect bottoms system and trays
Turnaround
Soaker drum
Jet out coke; measure the volume left
Multi-year turnaround
Tar pumps and valves
Inspect impellers and trim for wear by coke fines
Turnaround
Fuel oil stability
Run viscosity and sediment tests on the blended fuel
Per blend to weekly
FAQ
How does a visbreaker work?
It heats residue until its molecules crack. Atmospheric or vacuum residue is pumped through a fired furnace, where the oil reaches roughly 455 to 480 degrees Celsius under pressure with steam keeping it moving; in a coil unit the cracking finishes in the coils, in a soaker unit in a drum held at temperature for many minutes. A gas oil quench stops the reaction, and the stream flashes into a fractionator that yields sour gas and naphtha overhead, a steam stripped gas oil side draw, and visbroken tar from the bottom. The thinner tar meets a heavy fuel oil grade with less cutter stock, and a vacuum flasher can take more gas oil out of it.
Coil or soaker visbreaker: what changes?
Where the conversion happens. A coil unit runs a hotter furnace outlet and cracks the oil in a dedicated coil in seconds or minutes, so there is no soaker drum and the coil can be cleaned on line, a two-cell furnace taking one cell off at a time. A soaker unit runs a cooler furnace and finishes most of the conversion in a large drum over many minutes, which typically slows tube coking and lowers fuel cost but leaves a vessel that gathers coke and must be cleaned at turnarounds, and makes less steam. Yields and product quality are the same at equal severity, so the choice rests on furnace practice, turnaround pattern, and plot.
What specifications matter most in a visbreaker?
Start with the feed assay: Conradson carbon, asphaltenes, n-pentane insolubles, softening point, and sodium set the conversion allowed and the coking rate. Then read the furnace conditions, about 455 to 480 degrees Celsius and 3.4 to 17.2 bar (50 to 250 psig) at the heater outlet, the conversion to gas, gasoline, and distillate, which licensors put at 10 to 50 percent of feed, and the resulting tar viscosity, commonly a few hundred square millimetres per second at fifty degrees Celsius (122 degrees Fahrenheit). Add the stability limit of the blended fuel oil, the heater run length, and the heat recovery. Sodium matters because a clean desalter means longer furnace cycles.
How do I choose a visbreaker design?
Begin with the residue and the fuel oil the refinery must blend. A low asphaltene, low Conradson carbon residue allows a higher conversion and a thinner tar; a dirty residue should be run gently for stability and furnace life. Pick coil or soaker by where the refinery wants to put the time and the maintenance: on line coil cleaning, or a cooler furnace with a drum to clean at turnarounds. State the run length and the on-stream factor expected, and ask how on-line decoking and pass control achieve them. Decide where the gas oil goes, whether a vacuum flasher is built, and ask for yields under each scheme before comparing offers.
What inspection and maintenance does a visbreaker need?
The furnace sets the schedule. Tube skin thermocouples are trended continuously for the slow climb that means coke, and each pass's pressure drop and flow are checked against a clean baseline. When either reaches its limit the pass is cleaned, on line by steam-air burning or spalling where the furnace allows, otherwise at a shutdown. Sootblowers clean the convection section on a regular cycle. At turnarounds the fractionator is cleared of coke fines, tar pumps and control valves are inspected for erosion, the quench and transfer line are opened, and a soaker drum is jetted clean. Viscosity and sediment tests on the blended fuel oil confirm that the unit is inside its stability margin.
What drives the cost and lead time of a visbreaker?
The furnace, in most cases. Its duty follows the conversion target, and its alloy tubes, multi-pass coil, air preheater, and on-line decoking provisions are the long lead items and the largest share of the steel. A soaker drum adds a heavy pressure vessel; a vacuum flasher adds a tower and ejector set. The heat exchanger train, sized for a fouling tar service, and the tar pumps with wear resistant internals add more. Lead time also depends on the heat exchanger bundles and on how much room the downstream hydrotreaters, amine unit, and sulfur recovery unit have for the visbreaker's products.
What safety and standards apply to a visbreaker?
The hazards are hot oil under pressure in furnace tubes and a furnace burning fuel around the clock. Vessels follow the ASME Boiler and Pressure Vessel Code and piping ASME B31.3, with in-service inspection under API 510 and API 570; the furnace follows API 560 for fired heaters, with tube thickness calculated by API 530. Tube wall temperature limits, pass flow trips, and burner management protect the coils, and safety relief valves and rupture disks discharge to a knockout drum and a flare. Sour naphtha and hydrogen sulfide call for closed systems and detectors for hydrogen sulfide, and steam-air decoking is done under a written procedure with the burning front watched at every step.