An alkylation unit builds gasoline molecules instead of breaking them: it feeds isobutane and light olefins, usually propylene, butylene, and amylene, to a strong acid that joins them into branched paraffins known as alkylate, a blending stock commonly rated at a research octane in the low to mid nineties on a butylene feed, a low Reid vapor pressure, and no olefins or aromatics. The plant runs at four to ten degrees Celsius in sulfuric acid service and near blood heat in hydrofluoric acid service, as a loop of feed treating, a reactor with its acid settler, refrigeration, effluent washes, and towers that return unused isobutane. EPA emission factors, a South Coast AQMD technology study, and licensor descriptions from Elessent Clean Technologies and Honeywell UOP inform this page, which treats the complete unit as one purchasing object.
Specification work on such a unit starts long before a licensor is shortlisted. The questions come in a fixed order: which olefins and how much isobutane the refinery can supply, which acid the site is willing to handle, where the consumed acid goes, and what octane and vapor pressure the gasoline pool needs. The chapters below take them in that order, after explaining the reaction and the equipment, and keep to choices that are expensive to reverse once the unit is built: the catalyst, the refrigeration scheme, the metallurgy, and the acid supply route. Figures appear as the ranges a buyer will meet in commercial offers, not as design values for any one unit.
Five decisions carry most of the purchase: the olefin and isobutane slate, since propylene, butylene, and amylene behave differently and every feed impurity is paid for in acid; the acid system, which fixes the reactor, the cooling, the metallurgy, and the hazard; the spent acid route, whether acid is regenerated on site, leaves by truck or rail, or is revaporized inside the unit; the refrigeration and fractionation, which set the power bill and the isobutane recycle; and the mitigation systems, where an HF unit's permission to operate lives.
Chapter 1 / 06
What an Alkylation Unit Is and What Is Being Decided
Stripped to its equipment, an alkylation unit is a reaction loop wrapped in separation. Treated feed, a mixture of isobutane and olefins dried and freed of most sulfur compounds, enters a reactor where an impeller or a static mixer disperses hydrocarbon droplets through a continuous phase of acid. The emulsion flows to a settler, the acid sinks and returns to the reactor, and the hydrocarbon leaves for the rest of the unit. Heat leaves through the reactor, into boiling refrigerant or into cooling water. Downstream stand a flash drum and a compressor, wash vessels for acid, caustic, and water, and two or three towers that split propane, normal butane, isobutane, and alkylate.
Refinery conversion runs in two directions. Cracking, coking, and visbreaking break large molecules into small ones; alkylation and polymerization combine small molecules into larger ones. The feed is two streams that cracking units produce but cannot sell well on their own: isobutane, and olefins that would otherwise end up as liquefied petroleum gas or fuel. The product is a mixture of branched paraffins in the gasoline boiling range, typically about 1.8 barrels of alkylate per barrel of olefin fed, with propane and normal butane as byproducts. Branched and fully saturated, these molecules resist knock and carry none of the olefins and aromatics that gasoline rules restrict.
The purchase itself is a yield and quality guarantee with an acid and energy bill attached. The refinery is buying the conversion of a named olefin slate at a named rate into a named volume of alkylate of stated octane and vapor pressure, with acid consumption, compressor power, and isobutane makeup quantified, and with a hazard case that licensor and owner can defend to a regulator and a neighbor. Reactor count, settler volume, refrigeration duty, wash scheme, and tray count all trace back to that statement. Offers should rest on pilot or commercial results with the actual olefins; a bidder quoting another refinery's feed should be asked to explain.
Alkylate earns its place by being clean as well as loud. Its branched paraffins commonly carry a research octane in the low to mid nineties when butylene is the feed, with motor octane only a few numbers behind, so the sensitivity that costs aromatic stocks octane on the road is small. There are no olefins, no aromatics, and therefore no benzene in it, its sulfur is negligible, and its Reid vapor pressure is low enough that a blender can add more butane to summer gasoline. The same properties suit aviation gasoline. As ethanol takes a larger share of the pool and as benzene and sulfur limits tighten, a zero-aromatic source of octane becomes harder to replace.
Refineries buy the same unit for different reasons. A fuels refinery with a large fluid catalytic cracker buys it to raise the value of its C3 and C4 olefins. A refinery blending ethanol at volume needs more low-vapor-pressure stock that contains no aromatics, and licensors now pair their alkylation processes with butane isomerization so that isobutane can be made on site. A refinery operating an HF unit inside a densely populated air district studies conversion to sulfuric acid, to a solid or ionic liquid catalyst, or added mitigation, and that study is a procurement of its own. Studies of such conversions take twenty-five thousand barrels per day of alkylate (about four thousand cubic meters) as their estimating basis.
The economics are four costs against one credit. The credit is the octane and clean-burning value of alkylate over the olefins it is made from. The costs are acid, compressor power, isobutane makeup, and the capital tied up in hazard systems. A sulfuric unit spends more on acid and on power, since acid is consumed at roughly half a pound per gallon (about 60 grams per liter) and its refrigeration compressor and circulation pumps never stop, so it costs more to run than an HF unit of the same size. An HF unit spends almost nothing on acid, which is revaporized within the unit, and spends instead on detection, water mitigation, and rapid acid transfer.
Chapter 2 / 06
How an Alkylation Unit Does the Work
The reaction is acid-catalyzed and gives off heat. The acid activates a small fraction of the olefin as positively charged fragments. A tert-butyl cation derived from isobutane adds to an olefin to form a larger cation, and that cation then takes a hydrogen atom, electron pair included, from a fresh isobutane molecule, releasing a finished isoparaffin and regenerating the tert-butyl cation. Repeating the cycle gives the C7 to C12 isoparaffins of alkylate, the flagship being 2,2,4-trimethylpentane, the isooctane of the octane scale's hundred point. Side paths exist: olefins can link into heavy red oil that dissolves in the acid, and hydrogen transfer turns propylene into propane while using up a second molecule of isobutane.
Four operating variables decide how much olefin becomes good alkylate: temperature, acid strength, olefin space velocity, and isobutane concentration. Colder is better up to the point where the acid grows too thick to emulsify. Stronger acid is better up to a point, and acid diluted by water and by dissolved red oil reacts more slowly and gives a poorer product. Space velocity, the volume of olefin contacted per volume of acid per hour, is held low so that each olefin molecule meets isobutane rather than another olefin. Isobutane concentration is raised by recycling it in large excess. Every reactor design is a device for holding those four variables at their best values throughout the vessel.
In the workhorse arrangement a horizontal stirred reactor and a horizontal acid settler form the heart. The reactor is a pressure shell containing a tube bundle and a central circulation tube; a large impeller pulls the acid-continuous emulsion through the tube and drives it back across the bundle, and fresh olefin and isobutane enter at the impeller suction, so the olefin arrives already diluted in a much larger flow of recycle acid and recycle hydrocarbon. The acid-to-hydrocarbon volume ratio in the reactor is held near one to one. Mixed liquor flows to the settler, where the phases part under gravity, the denser acid dropping to the bottom for return and the hydrocarbon overflowing to the loop outlet.
Heat removal is what makes a sulfuric unit costly to run. In an effluent-refrigerated unit, part of the hydrocarbon leaving the settler passes through a control valve into a low-pressure flash drum, where some of its isobutane boils off; the cold two-phase stream flows through the reactor's tube bundle, takes up the reaction heat, and returns to the same drum. Vapor leaves the drum through a mist eliminator to a centrifugal compressor, which raises its pressure until it will condense and then sends it toward the depropanizer. A pressure transmitter on the drum and the control valve hold the flash pressure, and that pressure fixes the boiling temperature, and with it the reaction temperature.
The acid is catalyst and consumable at once. Acid returning from the settler outweighs the fresh feed many times over, so the reaction mixture sees a large reservoir of acid at nearly uniform strength. Impurities spend that strength: water and oxygenates dilute the acid, diolefins and sulfur compounds form red oil that dilutes it further, and every pound of dilution is made up with fresh acid. A sulfuric unit therefore bleeds spent acid at roughly ninety percent strength and takes in fresh acid at about ninety-nine percent, at roughly half a pound per gallon (about 60 grams per liter). An HF unit buys far less acid because it distills its acid clean in a tower inside the unit.
Hydrocarbon leaving the settler is not yet a product. It carries traces of acid and of reaction esters that break down in hot equipment and corrode it. A sulfuric unit washes it in sequence, with acid to take out the esters, then caustic, then water, each stage followed by settling; an HF unit passes its product over alumina to pick up organic fluoride. The washed stream is then fractionated. A depropanizer keeps propane from building in the recycle, a deisobutanizer takes isobutane overhead for return and often draws normal butane from the side, and a debutanizer, where one exists, strips the last light material to fix the alkylate's vapor pressure. What remains is alkylate, cooled and sent to blending.
Chapter 3 / 06
Acid Systems, Unit Types, and Machine Boundaries
The commonest sulfuric design, licensed under the STRATCO name, pairs horizontal stirred reactors with indirect effluent refrigeration. Each reactor is a single horizontal vessel that mixes and cools in the same shell, its tube bundle chilled by flashing effluent, and a settler returns its acid. The loop runs at about 4.1 bar gauge (60 psig) and four to ten degrees Celsius (forty to fifty degrees Fahrenheit), with an external isobutane to olefin ratio of eight to one or higher. One reactor with its settler is the smallest unit; larger capacities add further reactors and settlers in parallel, which is why a big sulfuric unit spreads over more plot than an HF unit of equal output.
The alternative sulfuric design is cascade autorefrigeration. Several stirred reactors stand in series at about 0.7 to 1.03 bar gauge (10 to 15 psig); feed and acid are mixed with cold recycle isobutane and allowed to boil in the reactors themselves, so the latent heat of the evaporating isobutane carries off the reaction heat and the vapor goes straight to the compressor. Olefin enters each stage and the acid cascades from one to the next, which keeps the local isobutane to olefin ratio high without a tube bundle. A newer arrangement uses a vertical reactor with a static mixer and runs below zero degrees Celsius, with a reported acid consumption about half that of the older designs.
Hydrofluoric acid alkylation is the same chemistry in a different solvent. The reactor is a shell-and-tube heat exchanger cooled by water, usually from the refinery's cooling tower, so the unit runs at roughly twenty-seven to thirty-eight degrees Celsius (eighty to one hundred degrees Fahrenheit) and has no refrigeration compressor. Acid moves between reactor and settler by centrifugal pump or by the density difference between warm and cold acid, the loop sits at roughly 6.9 to 8.3 bar gauge (100 to 120 psig), the external isobutane to olefin ratio is twelve to fourteen to one, and a regeneration tower revaporizes the acid, so make-up arrives by truck once or twice a month on an average sized unit. Ionic liquid alkylation, offered as the ISOALKY process, runs the reaction near ambient temperature in a salt catalyst with negligible vapor pressure that is regenerated on site.
Boundaries are worth stating because several neighbors appear on the same drawing. An alkylation unit is not a hydrotreater, which removes sulfur and saturates olefins under hydrogen, and not a delayed coker, which cracks vacuum residue into coke, gas, and lighter liquids; neither is part of this unit and neither is described again here. It is not the fired heater found in nearly every other conversion unit, because an alkylation unit has none: its reaction gives off heat, and every extra degree of warmth costs octane. Nor is it the packed tower of its deisobutanizer or the centrifugal compressor of its refrigeration circuit, parts that have their own entries in this encyclopedia.
The unit's connections explain its place in a refinery. Olefins come mainly from the fluid catalytic cracker, with smaller amounts from a delayed coker and a visbreaker after their cracked gas has been through the gas plant. Isobutane arrives with the feed or is made from normal butane, while pentanes and hexanes go to an isomerization unit, a neighbor that rearranges molecules instead of joining them. LPG byproducts pass an amine unit for hydrogen sulfide, the acid gas going on to a sulfur recovery unit, and wash water goes to a sour water stripper. Feed for an HF unit is dried on a molecular sieve dehydrator. Safety relief valves and rupture disks discharge to a knockout drum and then a flare stack.
Chapter 4 / 06
Key Specification Parameters
A licensor data sheet for an alkylation unit centers on feed, reaction conditions, acid, and product, and every number on it has a cost attached. The table that closes this chapter gives reaction temperature, reactor pressure, the two isobutane to olefin ratios, acid consumption, yield, and alkylate quality for sulfuric and HF service, with the ionic liquid unit described in the text instead. The reaction conditions, ratios, space velocities, acid consumption rates, and yields are the figures the AQMD study publishes; octane and vapor pressure are stated as the ranges common practice gives, since neither cited source prints a number. A buyer's own olefin slate and isobutane balance replace all of them at the guarantee stage.
Three of the parameters in that table deserve a closer look. The external isobutane to olefin ratio counts isobutane in the total reactor feed, recycle included, against fresh olefin; the internal ratio, the isobutane surrounding each olefin molecule at the moment of contact, is commonly several times higher still, because recycled acid and recycled hydrocarbon dilute the olefin as it enters. Acid strength is a controlled dilution rather than a purity: water and red oil lower it, and when it falls toward the titrated alarm point the reactor is at risk of a runaway. Acid consumption is best normalized per gallon or per barrel of alkylate, because that is the basis of the supply contract.
Materials follow the acid. Sulfuric acid from about ninety to one hundred percent by weight is handled in carbon steel because the acid passivates the steel; dilute acid, and the hot wet gas of a regeneration plant, call for lined pipe, high-alloy steel, and refractory. HF service is also carbon steel where the acid is dry, which is the reason for feed driers, and a nickel-copper alloy in the regenerator where water concentrates. Hydrocarbon coolers, the reactor tube bundle, and the deisobutanizer reboiler follow shell-and-tube heat exchanger practice and are sized for clean service, because acid carried over fouls and corrodes them together, and a fouled reboiler shows up first as a loss of separation in the tower.
Parameter
Typical catalog range
What it decides
Reaction temperature, sulfuric acid
4 to 10 C (40 to 50 F)
Octane; acid viscosity; refrigeration power
Reaction temperature, HF
27 to 38 C (80 to 100 F)
Cooling water duty; corrosion control
Reactor pressure, effluent refrigerated
about 4.1 bar g (60 psig)
Keeps the reaction liquid; tube bundle design
Reactor pressure, autorefrigerated
0.7 to 1.03 bar g (10 to 15 psig)
Vapor route to the compressor
Reactor pressure, HF
6.9 to 8.3 bar g (100 to 120 psig)
Vessel thickness; relief load
External isobutane to olefin ratio, sulfuric
8 to 1 or higher
Octane; recycle and tower size
External isobutane to olefin ratio, HF
12 to 1 to 14 to 1
Octane; isobutane makeup
Acid to hydrocarbon volume ratio
about 1 to 1
Emulsion quality; settler size
Olefin space velocity, sulfuric and HF
0.2 to 0.3 and 0.3 to 0.5 per h
Acid inventory; byproduct formation
Sulfuric acid consumption
0.4 to 0.6 lb/gal (48 to 72 g/L)
Supply contract; regeneration size
HF acid consumption
0.001 to 0.002 lb/gal (0.12 to 0.24 g/L)
Truck deliveries; acid inventory
Alkylate yield
1.77 to 1.78 bbl per bbl olefin
Alkylate made per olefin fed
Alkylate research octane, C4 feed
low to mid 90s
Blending value of the product
Alkylate Reid vapor pressure
roughly 2 to 5 psi (14 to 35 kPa)
Summer blending; debutanizer need
Chapter 5 / 06
Selection Decision Factors and RFQ Language
Selection starts with the slate, not with the acid. Propylene, butylene, and amylene each alkylate best under different conditions. Propylene and amylene push hydrogen transfer, which raises isobutane consumption and yields propane or isopentane instead of alkylate; processing them apart from butylene lowers acid consumption and raises octane, at the price of extra reactors and towers, and may need upstream towers to split the olefins. The isobutane balance comes next: how much arrives with the feed, how much must be bought or made from normal butane, and how much propane comes along with it. Water, sulfur, diolefins, and oxygenates each carry a price in acid, so feed pretreatment is a selection item of its own.
The acid system then sets the machine. A buyer who picks sulfuric acid gets cold reactors, a large refrigeration compressor, a steady supply of fresh acid by truck or rail, and a regeneration plant on site or at a merchant; the acid burns where it lands but does not travel as a vapor cloud. A buyer who picks HF gets cooling water, a small acid bill, and a compact plot, and in exchange a hazard case that depends on detection, water mitigation, rapid acid transfer, and the distance to the fence line. Ionic liquid buys a nonvolatile catalyst, a short logistics train, and a shorter commercial record; its licensor reports consumption hundreds of times below a sulfuric unit's acid rate, accepts olefins from ethylene to amylene, and still needs dry feed.
The spent acid route is a procurement decision hiding inside a technology decision. A sulfuric unit without on-site regeneration brings in fresh acid at about ninety-nine percent strength and ships spent acid out at about ninety percent by tank truck or rail; for a nominal twenty-five thousand barrel per day unit (about four thousand cubic meters), the South Coast AQMD study counted twenty to thirty truck movements a day against two to four a month for an HF unit. Spent acid holds dissolved light hydrocarbon, so its tank needs an inert gas blanket and full containment. A regeneration plant on site removes the truck movements and adds a furnace, a larger plot, and a sulfur oxide emission source inside the refinery. Wherever the plant sits, regeneration runs five steps:
Burn the spent acid to sulfur dioxide and water, destroying its dissolved hydrocarbon and red oil.
Cool the gas in a waste heat boiler and clean it of particulates and acid mist.
Oxidize the sulfur dioxide to sulfur trioxide over a catalyst with added air.
Absorb the trioxide in strong acid to make fresh acid near ninety-nine percent strength.
Treat the tail gas for sulfur and nitrogen oxides before release.
For an HF unit the constraint to write into the RFQ is mitigation, itemized with performance figures. Hydrogen fluoride boils at about nineteen degrees Celsius (about sixty-seven degrees Fahrenheit) and, escaping from a warm pressurized leak, forms a heavy aerosol able to travel beyond the fence line. The buyer states which systems are required: acid detection by point gas detector loops, open path beams, or both; remote cameras; acid-sensitive paint that exposes small leaks; water curtains and monitors with their deluge valves and design water rate; a rapid acid transfer system sized to empty the reactor and settler; and remotely operated block valves isolating each acid inventory. More than one thousand pounds (about 450 kilograms) of hydrogen fluoride on site brings a risk management plan, so the acid holdup is a selection variable.
Capacity and the revamp path close the list. A sulfuric unit grows by adding reactor and settler pairs, so beyond a certain size it costs plot and piping per barrel that a single HF reactor system avoids. An HF unit converted to another acid can usually keep its fractionation section, because the other acids work with a lower isobutane to olefin ratio; one study pictures a new reactor section built beside the old one, for a shutdown near sixty days. Compressor power and regeneration fuel belong in the operating cost comparison. Octane and vapor pressure by feed slate are the numbers every guarantee is normalized against, and they must be stated.
Nine questions follow, and a licensor will ask each of them back if the RFQ leaves it open. They run from the olefin slate and the isobutane balance through the acid system and the spent acid route to the energy the unit will draw, and each names what goes wrong when the answer is missing.
Decision factor
What the buyer must state
Consequence if left open
Olefin slate
Propylene, butylene, amylene; separate or mixed processing; design and maximum rate
Acid consumption and octane guessed; reactor count wrong
Isobutane balance
Isobutane in feed, makeup source, propane content
Recycle and depropanizer undersized; isobutane bought at spot
Refrigeration power, cooling water, fuel for regeneration
Operating cost above the study estimate
An alkylation RFQ has to name the molecules and the acid before it names any equipment. A bid-ready specification states: the olefin and isobutane slate, with propylene, butylene, and amylene proportions, design and maximum olefin rate, isobutane makeup source, propane content, and the water, sulfur, diolefin, and oxygenate limits left after pretreatment; the alkylate octane and Reid vapor pressure target, with research and motor octane by feed slate and the test methods; the preferred acid system, sulfuric, HF, or ionic liquid, with reactor arrangement and refrigeration scheme open to the bidder where flexibility is wanted; and the spent-acid or HF-mitigation constraints, meaning regeneration on site or off site, truck or rail supply, tank containment and inerting, or the detection, water mitigation, rapid transfer, and remote isolation systems required; then effluent treating, fractionation, and butane disposition; utilities at the battery limit; and the acceptance basis, a performance test at full rate with acid consumption and alkylate quality measured against the guarantee.
Chapter 6 / 06
Installation, Standards, Failure Modes, and Maintenance
Installation is cold-service vessel work with an acid layer on top. Reactors and settlers lie horizontally on their supports, the refrigeration compressor takes its own foundation, and the towers rise over a piperack carrying acid, caustic, and water lines beside the hydrocarbon. Acid lines in carbon steel are sloped and drained, with no dead legs where dilute acid can collect, and bolted joints in acid service are kept to a minimum and shielded; cold hydrocarbon lines are insulated against frost. The acid unloading area, the fresh and spent acid tanks, and their containment walls belong to the footprint. Commissioning dries and passivates the acid system, fills the acid inventory, and only then introduces olefin at a low rate.
Standards for alkylation units are pressure, piping, process safety, and acid-handling practice rather than one machine standard. Vessels follow the pressure equipment code of the jurisdiction, the ASME Boiler and Pressure Vessel Code in the United States, and process piping follows ASME B31.3. HF alkylation units operate under an API recommended practice numbered 751, written for that service, which covers safe operation and the mitigation described above. Vessels and piping are then inspected at the intervals of the in-service inspection codes API 510 and API 570, with extra attention to the regeneration circuit. The RFQ should name the codes current at purchase rather than copying a list from an older specification.
The recurring failure modes sit where acid meets hydrocarbon and where heat leaves. Acid runaway is the one operators fear: dilute acid, rising temperature, and continued olefin feed let the reaction feed on itself, the acid turns dark and gives off sulfur dioxide and carbon dioxide, and the reactor foams; the response is to cut olefin and keep isobutane circulating. Acid entrainment, from a lost settler interface or a wash short of caustic, carries acid into the towers and corrodes the deisobutanizer reboiler. A compressor trip sends reactor temperature up within minutes, and in HF service a loss of feed drying raises corrosion in carbon steel.
The instruments that matter are few and watched constantly. A differential pressure transmitter across the reactor shows whether the emulsion is flowing or the tube bundle is fouling; a level transmitter on the settler tracks the acid-hydrocarbon interface, the one reading that keeps acid out of the washes and towers; a pressure transmitter on the flash drum fixes the refrigeration temperature; temperature transmitters at the reactor outlet and on the washes show the heat balance and any acid carryover; each olefin feed has its own flow meter so that space velocity can be held when a stream drops out. Acid strength, water, and red oil come from titration each shift, and their trend against olefin fed is the unit's health record.
On an alkylation unit the calendar belongs to the acid: how fast strength falls sets the laboratory and unloading routine, and the turnaround, four to five years apart in licensor experience with sulfuric units, sets when vessels are opened. The cadence column below is common practice; the licensor's manual and the local inspection rules set the dates.
Item
Typical action
Typical cadence
Acid strength and consumption
Titrate acid for strength, water, and red oil; reconcile fresh acid against olefin fed
Every shift to daily
Settler interface and washes
Verify the interface reading; check caustic strength and water wash pH
Daily
Stirred reactor
Inspect seals and lubrication; trend power draw and differential pressure
Continuous trend, weekly walk-down
Refrigeration compressor
Inspect seals and vibration; clean the suction trap mist eliminator
Continuous trend, quarterly
Flash drum control valve
Inspect for erosion by flashing two-phase flow; check stroke
Quarterly to semi-annual
Acid piping and tanks
Walk down for drips and acid-indicating paint marks; verify containment and inerting
Monthly
Towers and reboiler
Inspect the deisobutanizer reboiler for fouling; check trays or packing
Turnaround
Relief devices
Proof test safety relief valves; renew rupture disks
Turnaround
Mitigation systems, HF units
Test detection, water curtains, rapid acid transfer, and remote block valves
Fixed test schedule
FAQ
How does an alkylation unit work?
It joins isobutane to light olefins over a strong acid. Treated feed enters a reactor where an impeller or a static mixer disperses hydrocarbon in a continuous phase of sulfuric acid, HF, or an ionic liquid; the acid activates the olefin and a chain of reactions builds branched paraffins, chiefly isooctane, while the heat released leaves through a tube bundle or by evaporating isobutane. The emulsion settles, acid returns to the reactor, and hydrocarbon is washed free of acid and reaction esters. Towers then split propane, normal butane, and recycle isobutane from the alkylate, and the isobutane goes back to the reactor.
Sulfuric acid or HF: what changes in an alkylation unit?
Sulfuric units run cold, 4 to 10 degrees Celsius (40 to 50 degrees Fahrenheit), need a refrigeration compressor, consume acid at roughly 0.4 to 0.6 pound per gallon (48 to 72 grams per liter), and send spent acid out to a regeneration plant or regenerate it on site. HF units run near ambient, cool with water, consume about 0.001 to 0.002 pound per gallon (0.12 to 0.24 gram per liter) because the acid is revaporized inside the unit, and occupy less plot. The price of HF is its hazard: a release forms an airborne acid aerosol, so these units carry detection, water mitigation, and rapid acid transfer. Ionic liquid units seek a middle ground with a nonvolatile catalyst.
What specifications matter most in an alkylation unit?
Start with the feed slate and the ratios. The external isobutane to olefin ratio is typically 8 to 1 or higher for sulfuric acid and 12 to 14 to 1 for HF; olefin space velocity, volumes of olefin per volume of acid per hour, sits in the 0.2 to 0.5 range. Reaction temperature and pressure follow the acid. Then read acid consumption, alkylate yield at about 1.8 barrels per barrel of olefin, and alkylate research octane, commonly in the low to mid 90s for a butylene feed, together with its Reid vapor pressure. Last come the utilities: compressor power, cooling water, and caustic.
How do I choose an alkylation technology?
Begin with the olefins you have and the acid your site can live with. Octane can come from a catalytic reformer, which makes aromatics, or from this unit, which consumes olefins, so the value depends on how many olefins the refinery makes. A large butylene stream with plentiful isobutane favors a conventional stirred reactor sulfuric unit; propylene or amylene in quantity argues for separate processing. Then decide where spent acid goes: a merchant regeneration plant within trucking distance, or an on-site plant with its furnace and emissions. Where a regulator will not accept an HF aerosol hazard, the choice is made for you. Ask for acid consumption and octane guarantees on your own slate.
What inspection and maintenance does an alkylation unit need?
The acid side sets the schedule. Operators titrate circulating acid each shift for strength, water, and red oil, and reconcile fresh acid deliveries against olefin fed. The settler interface instrument is checked daily, because a lost interface carries acid into the washes and towers. Reactor seals and power draw, tube bundle differential pressure, and the flash drum control valve, which sees flashing two-phase service, are trended and inspected quarterly. Acid lines, tank containment, and inerting get a monthly walk-down. Towers, the deisobutanizer reboiler, relief devices, and the mitigation systems of an HF unit are overhauled at turnarounds, four to five years apart in well run sulfuric units.
What drives the cost and lead time of an alkylation unit?
Four things. Acid logistics: an on-site regeneration plant adds a furnace, a gas cleaning train, and plot, and lengthens permitting; off-site regeneration adds a supply contract and truck or rail traffic. Refrigeration: the large centrifugal compressor of a sulfuric unit is a long lead item and its main running cost. Metallurgy and mitigation: nickel-copper alloy in HF regeneration, high-alloy steel in spent acid service, and water curtains and transfer systems all extend engineering and purchasing. Capacity: each added reactor and settler pair, with its towers, adds vessels, piping, and structural steel. How much of an existing unit can be reused also sets the calendar.
What safety and standards apply to alkylation units?
Two hazards run through the unit: strong acid and light hydrocarbon under pressure. Vessels follow the ASME Boiler and Pressure Vessel Code and piping ASME B31.3, with in-service inspection under API 510 and API 570. HF alkylation units are governed by API Recommended Practice 751, which calls for acid detection, water mitigation, rapid acid transfer, and remote isolation; an HF inventory above 1,000 pounds (about 450 kilograms) triggers a risk management plan. Sulfuric units manage burns and spent acid transport, and keep an inert blanket on the spent acid tank. Relief loads go to a knockout drum and a flare. Feed drying and passivation before feed is introduced complete the case.