Bulkhead Pass-Through Connector

A bulkhead pass-through connector is a connector fixed in a rigid partition: the wall of a control cabinet, an enclosure lid, a machine frame bulkhead, or the wall of a vacuum or pressure vessel. It presents a mating interface on each side, so two cordsets, or a cordset and a device cable, join through the panel while the cable stays factory-overmolded from end to end. Nothing is cut, stripped, and landed on terminals at the wall. The same idea is sold as a bulkhead adapter, a panel feed-through, a wall-through connector, or a double-ended receptacle, and it is built in forms that range from an M12 thread-in sensor feed-through to a 300-pin sub-miniature D feedthrough sealed into a vacuum fitting.

This page is for the engineer who has to carry power, signals, network cables, or light through a partition and keep that partition weathertight, grounded, and certifiable once the cable has crossed it. The chapters cover the forms on the market, the seals and cut-outs that hold the ingress rating, contact counts with current and voltage ratings, shield continuity, cable entry from each side, corrosion and mating-cycle limits, installation, inspection, and the checks a buyer makes before placing an order. Ratings for M8 and M12 feed-throughs, rectangular industrial housings, military-pattern receptacles, and vacuum feedthroughs are taken from the manufacturer documents and the standards listed in the sources. Figures that no source states are marked typical. A cable gland is the neighboring device, and the difference between the two is drawn once, in the chapter on types.

Three M12 connectors seen end-on: a nickel-plated socket with four pins fixed through a black panel housing at the top, and two cable-mounted plugs with knurled metal coupling rings below it.

Photo: Phiarc, CC BY-SA 4.0, via Wikimedia Commons

The buying decision for a bulkhead pass-through connector concentrates in five places. The interface on each face comes first, since it has to match the cordsets already chosen on both sides of the wall. The seal comes second: the rating when mated, and what the wall still keeps out when a cordset is unplugged. Third is the electrical duty, because a feed-through puts two contact interfaces into every conductor. Fourth is the panel, its thickness, cut-out, finish, and the clear space behind it. Fifth is the environment, washdown, salt spray, vibration, or vacuum, which picks the shell and seal materials.

Chapter 1 / 06

What a Bulkhead Pass-Through Connector Is and How It Works

An ordinary fixed connector has one mating face and one termination. The cable side is finished in the field by crimping, soldering, or landing on a printed circuit board, and that work is where wiring errors and uneven strain relief enter. A bulkhead pass-through connector deletes that step at the wall. Its contacts are straight-through pieces with a mating contact on each end, so the device is a pair of fixed connectors joined back to back inside one body. One maker of military-pattern parts states the purpose plainly: the feed-through removes the need for discrete wire termination when the connector is assembled. The cable work moves to where it belongs, at the overmolded cordset ends.

The two faces need not be the same gender. Military-pattern feed-throughs are ordered as socket-pin, pin-socket, pin-pin, or socket-socket, and the order of the two letters says which face carries which, while the in-line style can be reversed. A socket-pin part has recessed sockets on one face and pins on the other, so a cordset with pins meets it on the socket side. Choosing the gender pair is how a designer keeps the live side of a circuit on recessed contacts and the exposed face of an open connector free of pins that can bend or short. The fiber-optic version is built with pin termini on both ends, because light has no gender and the alignment sleeve sits in the mating half.

Five working parts make up any version. The shell or body carries the mating interface and gives the coupling thread or the keying that stops a wrongly coded plug from entering. The mounting feature fixes the body to the partition: a mounting thread and its mounting nut, a jam nut on a threaded barrel, a square mounting plate with four holes, or a bolted vacuum fitting. The contact carrier holds the contacts in place and insulates them from each other and from the shell; it is a polyamide insert in M12 types, a PEEK body on some vacuum sockets, and glass or a glass-ceramic in hermetic types. Seals close the panel joint and the mated interfaces, and wired versions add a short pigtail, a crimp barrel, or an insulation-displacement terminal between the through-contact and the cable.

Water has three ways through a pass-through, and each has its own seal. The panel joint is closed by a flat gasket or an O-ring compressed between the body and the partition when the mounting nut or the mounting screws are tightened. The mated interfaces are closed by an interface seal that works only when the plug is fully seated, which is why a manufacturer rates its M12 parts IP67 mated and locked, not bare. The cable exit is the third path: closed by the overmold of the cordset, by the cable gland on a hood, or by the seal of the feed-through's own pigtail. Rectangular industrial housings make the split visible. The standard housing holds IP65, IP67 needs a special bulkhead mounted housing, and a self-closing cover gives only IP44 while the cover is not locked.

An electrical shield that stops at the wall stops working at the wall, so the body of a pass-through is part of the shield path. In metal versions the cable screen lands on the shell at the hood, the shell is clamped to bare metal, and the screen continues in the cordset beyond. A maker of rectangular housings describes the construction as a continuous shield connection using a conductive surface and a conductive seal, and lists PTFE and NBR as the seal materials of those EMC housings; the D-coded M12 feed-through is listed with a 360 degree shielding termination. The military-pattern family quotes shielding effectiveness of 65 dB minimum at 10 GHz, obtained with solid metal-to-metal coupling and grounding fingers. A painted panel or an anodized thread between the body and the partition breaks that path without breaking the circuit.

In service the device ages at its four weakest points. Current meets two contact interfaces per conductor, and each one is rated at 10 milliohms in the M12 tables, a resistance that turns into heat inside a closed housing. Each mating cycle slides the contact springs against each other and wears the interface seal, so the cycle rating of 100 quoted for M12 feed-throughs is a real limit and not a formality. Vibration works on the mounting nut, the mounting screws, and the coupling thread, and a joint that loosens by a fraction of a turn loses both its seal and its shield bond. Where the shell and the partition are different metals, a wet boundary turns into a galvanic couple. Hermetic feedthroughs add a fifth, the glass-to-metal seal, which can leak if welding overheats it.

Chapter 2 / 06

Bulkhead Pass-Through Connector Types and Structural Variants

Heavy-duty rectangular types come from the industrial connector system that mates a hood to a fixed housing. Two housing styles turn that system into a pass-through. A bulkhead mounted housing is a fixed housing closed by a cover on its back; it carries one insert and closes the cut-out, and its rating depends on the cover fitted. A panel feed through housing carries an insert on both faces, each closed by its own hood, listed with a top entry and a cable entry of M25 or M32. The smallest size needs a panel cut-out of 22 x 22 mm (0.87 x 0.87 in). Protection covers for bulkhead mounted housings keep the wall sealed when a hood is removed, and the hoods and housings are rated from -40 to 125 degrees Celsius (-40 to 257 degrees F).

Circular sensor connectors become pass-throughs when a second mating face is added behind the first. An M12 panel feed-through is a double-ended receptacle whose barrel carries an M16 x 1.5 mounting thread and a mounting nut; the M8 size follows the same construction. It comes with crimp terminals, with an insulation-displacement terminal assembled on site, or with flying leads 50 cm (19.7 in) long. Codings run from A for sensors and actuators through B for fieldbuses and D for Ethernet to X for high-speed Ethernet. It fits panels from 2.5 to 4.5 mm (0.098 to 0.177 in) thick, or 2.0 to 5.0 mm (0.079 to 0.197 in) on the flying-lead version. A 7/8 inch feed-through and a Pg 13.5 or M20 feed-through carry power.

Military-pattern feed-throughs are double-ended receptacles that mate with standard series III plugs, the scoop-proof, threaded-coupling connectors of airframes. A jam nut receptacle threads into a round hole from one side and is locked with a thin nut on the far side, so it needs wrench access on both faces. A wall mount receptacle has a square mounting plate fixed with four screws. Shell sizes run from 9 to 25, and the jam nut and wall mount versions take panels from 0.060 to 0.150 in (1.5 to 3.8 mm) thick. Shell finishes set the temperature limit at 175 or 200 degrees Celsius (347 or 392 degrees F), the family range starts at -65 degrees Celsius (-85 degrees F), and a stainless steel class offers firewall capability.

Hermetic feedthroughs are the pass-through of vacuum and pressure engineering, and their seal is not an elastomer but glass or ceramic fired to metal. The common form is a fixed connector sealed into a vacuum fitting: a sub-miniature D pattern with 9 to 300 pins on a copper-gasket ultra-high vacuum fitting, or on small O-ring clamped fittings for high vacuum. Pins are gold-plated nickel alloy that expands with the glass-ceramic seal, and the body is 316L stainless steel. Such a part is rated for 500 V DC, 5 A per pin, 3 A per pin with all pins loaded, and -200 to 230 degrees Celsius (-328 to 446 degrees F). It is leak tested to below 5 x 10^-10 mbar l/s of helium and bakes out at 200 degrees Celsius (392 degrees F); versions for over-pressure reach 300 bar.

Fiber-optic and coaxial bulkheads pass a signal instead of a current, so their precision is geometric. A multi-channel fiber feed-through in the military series III pattern carries size 16 fiber termini in a pin-pin arrangement, seats with a jam nut, and is offered for 50/125 and 62.5/125 micron multimode fiber; a red band on the shell shows when it is fully mated. On vacuum chambers, fiber crosses either as an all-metal sealed feedthrough with a short fiber sealed into the body and coupled inside, or as an O-ring sealed coupler for high vacuum down to 10^-8 mbar. Coaxial feedthroughs keep a controlled 50 ohm line through the wall: a glass-sealed 2.92 mm type is specified from DC to 40 GHz, 1 kV RMS, and seals to its mounting with a fluororubber O-ring.

The boundary with the neighboring device is a matter of what crosses the wall. A cable gland seals a cable that is cut, stripped, and wired to terminals inside the enclosure; it carries no contacts and it decides nothing about connectors. A bulkhead pass-through connector carries contacts and makes the cable enter as a finished cordset, so nothing inside the enclosure is rewired. The two often work together, the gland on the cable entry of a hood that plugs into a panel feed through housing. Single-sided panel receptacles and PCB headers are not pass-throughs either, because their far end is a solder joint. The pass-through sits between a device cable on one side, from a proximity sensor, a servo motor, or an industrial switch, and the wiring on the other side, a remote IO module, a PLC, or an industrial PC reached through the wiring duct.

Chapter 3 / 06

Bulkhead Pass-Through Connector Key Specifications and Standards

Electrical ratings are written per contact. The M12 interface is standardized for 2 to 17 ways, at up to 250 V and up to 4 A per contact; one maker rates its M12 family at 4 A for 2 to 5 ways and 2 A for 6 to 8 ways. Feed-through versions quote lower voltages than the interface allows, 32 V on the insulation-displacement types, 50 V on the board adapter, and 24 V AC or DC on the B-coded pass-through. The contacts take 0.14 to 0.34 mm2 wire, listed as AWG 26 to 22. Power moves up a size: the 7/8 inch feed-through carries 10 A, the Pg 13.5 or M20 feed-through 16 A at 230 or 400 V, on 0.75 to 1.5 mm2 wire listed as AWG 18 to 16.

Ingress protection is stated as a condition, never as a bare code. M12 and M8 feed-throughs are rated IP67 when mated and locked, and the same connectors carry IP67 or IP68 as a family. An IP enclosure rating belongs to the assembled wall, so one unsealed crossing lowers the cabinet to the rating of that part. Rectangular housings hold IP65 as standard, IP67 only with a special bulkhead mounted housing, and IP44 under a self-closing cover that is not locked; the washdown grade reaches IP65, IP66, IP68, and IP69K for the coupled connector. IEC 60529 defines these codes for enclosures of equipment rated up to 72.5 kV, and a NEMA enclosure rating states the same kind of protection in the North American system.

Mechanical figures decide how long the seal and the contacts last. M8, M12, 7/8 inch, and Pg 13.5 or M20 feed-throughs are rated for 100 mating cycles, the military coupling for 500 mating cycles, and the fiber termini for 500 cycles. Coupling torque is exact: 0.6 Nm (0.44 lbf ft) on an M12 coupling nut and 0.4 Nm (0.30 lbf ft) on M8. One military-pattern family is tested to 60 G sine vibration from 140 to 2000 Hz and 300 G half-sine shock of 3 ms. Three standards apply: IEC 61076-2-101 is the detail specification for M12 connectors with screw locking, IEC 61984 gives safety requirements and tests for connectors rated above 50 V up to 1000 V and up to 125 A per contact, and UL 1977 covers component connectors for data, signal, control, and power.

ParameterTypical ratingWhat it decides
Ways, M12 interface2 to 17Conductors per position; more ways, less current
Rated current, M12 signal4 A at 2 to 5 ways; 2 A at 6 to 8 waysWire size and heating in the housing
Rated current, power types10 A, 7/8 inch; 16 A, Pg 13.5 or M20Whether a motor can cross on one part
Rated voltage, M12 feed-through24 to 50 VThe part rating governs, not the interface
Ingress protection, matedIP67 or IP68Outdoor and washdown duty
Ingress protection, rectangularIP65; IP44 with cover openWhat the wall holds with a hood removed
Panel thickness, M12 feed-through2.0 to 5.0 mm (0.079 to 0.197 in)Compression of the panel seal
Panel thickness, military type0.060 to 0.150 in (1.5 to 3.8 mm)Jam nut grip and plate seating
Mounting thread, M12 feed-throughM16 x 1.5The hole the panel needs
Coupling torque0.6 Nm (0.44 lbf ft), M12Seal compression without stripping
Mating cycles100, M8 and M12; 500, military couplingHow often the wall may be opened
Temperature, M8 and M12-40 to 85 degrees Celsius (-40 to 185 degrees F)Ambient limit of insulator and seal
Vacuum D feedthrough5 A per pin; 500 V DCInstrumentation on one feedthrough
UHV feedthrough leak ratebelow 5 x 10^-10 mbar l/sBakeout and pumping to UHV
Chapter 4 / 06

Bulkhead Pass-Through Connector Selection and Duty Calculations

Selection runs in a fixed order. Fix the interface on each face first, because the cordsets on both sides of the wall set it. Then check the electrical duty, the panel, the seal, and the environment, in that order, and only then settle shell finish and termination method.

The interface on each face follows from the cordsets that will meet it, and the two faces are chosen separately. A sensor cordset outside meets an A-coded M12 face, and the cable that continues inside to a remote IO module meets the second A-coded face, so the wall adds no adapter. Where one side is exposed to damage, that side gets the sockets, because a recessed socket survives a knock that bends a pin. Codings that differ in shape keep a power plug out of a signal feed-through, and the B, D, and X codings each reject the others. For a device already wired with a fixed cable, the pass-through is chosen to its connector and not the other way round.

The electrical duty starts with the current in each contact and ends with the temperature inside the housing. Contact resistance is listed at 10 milliohms for M12 types, so a contact pair carrying 4 A dissipates 0.16 W and drops 0.04 V. A pass-through puts two such pairs in series in every conductor, which gives 0.32 W and 0.08 V per conductor, and 1.3 W for a 4-pole part with every pole loaded. Current carrying capacity falls as ambient temperature rises, because the limit is the maximum temperature of the insert and contact materials. An enclosure that already runs hot needs the next size up, a 7/8 inch or Pg 13.5 or M20 feed-through rated 10 A or 16 A, and not an M12 part run at its limit.

The mating budget is the second calculation, and it is arithmetic on the cycle rating. An M12 feed-through is rated for 100 mating cycles, and a weekly changeover that unplugs the cable at the wall spends about 52 of them a year, so the wall connection reaches its rating in under 2 years. A monthly unplugging spends 12 a year and lasts about 8 years. The designer therefore keeps frequent disconnection away from the wall: the sensor or tool is unplugged at its own cordset end, and the pass-through stays mated for the life of the machine. Where the wall connection must be broken often, a military-pattern part rated for 500 mating cycles is the correct family, and its coupling is made for repeated use with a threaded nut that closes in one 360 degree turn.

The panel comes third. Its thickness must lie inside the range of the part, 2.5 to 4.5 mm (0.098 to 0.177 in) on crimp and insulation-displacement M12 feed-throughs and 0.060 to 0.150 in (1.5 to 3.8 mm) on a military jam nut receptacle; a panel outside the range gets a spacer or a counterbore. The cut-out follows the mounting: a tapped M16 x 1.5 hole, or a round hole with wrench room on both faces for a jam nut. On a vacuum chamber the mating vacuum fittings set the bolt circle, a baseplate feedthrough needs a 1 in (25.4 mm) hole in a plate no thicker than 32 mm (1.26 in), and the voltage rating of a feedthrough holds only under vacuum, below 1 x 10^-3 mbar.

Environment picks the shell and the seal. In washdown areas the body is stainless steel or coated zinc die-cast, the housing is the grade rated IP69K for the coupled connector, and the elastomer is chosen for the detergent: an NBR seal, a nitrile rubber, serves general duty and a fluororubber O-ring seals vacuum parts. Outdoors and offshore the salt spray figure is the test, 500 h for the military shells and for the washdown rectangular housings, and a zinc body bolted to a stainless partition is a galvanic pair that needs an isolation washer. In vibration, the 60 G rated military family and a metal body with a torque-controlled mounting nut hold their seals. On a hazardous-area wall the pass-through is part of an explosion proof junction box only when the certified assembly includes it, and a standard M12 part is not a substitute.

Selection factorWhat to state or checkHow it changes the choice
Interface each faceCoding, ways, gender of both cordsetsSets the family; faces need not share gender
Current per contactLoad with all contacts loadedAbove 4 A moves to a power feed-through
Mated ingress ratingIP67 or IP68, mated and lockedOutdoor and washdown walls need sealed versions
Open-face conditionCap or cover fitted when unpluggedA cover preserves IP65; a bare face has none
Panel thicknessThickness at the hole, thread or openingOutside 2.0 to 5.0 mm needs a spacer
Shield continuityBare metal, conductive seal, 360 degree terminationNetwork and drive cables need the metal version
Mating frequencyUnmatings a year against 100 cyclesFrequent changeovers need a 500 cycle type
Corrosion, washdownSalt spray hours, IP69K, shell and panel metalsMarine and food areas take stainless steel
Vacuum or pressure wallUltimate pressure, bakeout, differential pressureUltra-high vacuum needs a glass or metal seal
Chapter 5 / 06

Bulkhead Pass-Through Connector Installation, Maintenance, and Failure Modes

Most pass-through failures are made at installation, not in service. The sequence below follows the order in which the seal, the thread, the bond, and the contacts are committed, because each step is hard to inspect once the next one is done.

Preparation is where the seal is won or lost. Measure the panel thickness at the hole, paint included, and set it against the range of the part before cutting anything. Cut the hole to the mounting style, a tapped M16 x 1.5 hole for an M12 feed-through or a square opening for a rectangular housing, and deburr both faces, because a burr under a flat gasket is a leak path. On shielded versions remove the coating in a ring around the hole so the body bonds to bare metal. Check that the seal is present before the part goes in: several housings reach IP65 or IP67 only with a seal screw that is ordered separately. For angled bulkhead housings with through holes in the mounting plate, the fixing screws must seal against the inner part of the housing.

  1. Insert the body from the outside face and seat the panel seal flat, without dragging it across the edge of the hole.
  2. Run the mounting nut or jam nut down by hand to prove the thread is true, then tighten it with a torque wrench to the maker's figure; tighten a square mounting plate in stages across the diagonals so that its gasket compresses evenly.
  3. Land the cable side and clamp the cable close to the body so that no pull reaches the contacts; M8 system cables are specified with a bending radius of 10 x the outer diameter, and a moving cable runs in a cable drag chain on drag chain cable.
  4. Mate both cordsets by hand until the threads run freely, then tighten the coupling nut to 0.6 Nm (0.44 lbf ft) on M12; the mating force is 15 N (3.4 lbf) at most.
  5. Fit the cap or cover on any face left open, then prove the job: continuity on every conductor, a low-resistance bond from shell to panel, and a leak check on a vacuum feedthrough.

Cable entry differs on the two sides. Outside, the cable arrives as a cordset with its own overmold, so the entry is the mating plug and nothing else. Inside, three arrangements exist. The through-contact ends in a second mating face, and a second cordset continues to a PLC or a signal isolator. It ends in crimp or insulation-displacement terminals, and a control cable is terminated on site with the maker's tool. Or it ends in flying leads of 50 cm (19.7 in), which are landed on a terminal block or dressed into a wiring duct. On a rectangular housing each side takes a hood with a cable entry for a gland, and the hood locking screws are tightened to 2 Nm (1.5 lbf ft) for M4, 3 Nm (2.2 lbf ft) for M5, or 4 Nm (3.0 lbf ft) for M6.

Inspection is short and needs few instruments. Look first for the cap on any open face, since the dust caps sold for M8 and M12 are rated IP67, and for corrosion creeping from the mounting nut onto the panel. Turn each coupling nut by hand to feel a loose mounting nut or a body turning in its hole. Look into a socket face with an industrial borescope for a bent pin. Measure with a micro-ohmmeter from the cordset on one side to the cordset on the other, and treat a step change against the commissioning record as a worn contact. Check insulation between adjacent contacts and between each contact and the shell with an insulation resistance tester; the M12 family is specified at 100 megohms minimum. On a vacuum feedthrough, a leak check after every bakeout closes the list.

Four failure modes recur, and they share one cause, a seal or a spring that is no longer where it was. Ingress at the gasket follows a seal left out, a panel outside the thickness range, a mounting screw through a painted hole, or a mounting nut loosened by vibration; the water appears at the lowest contact, far from the path. Bent pins come from mating at an angle or from a plug forced against the keying, and they end as an open circuit or a short to the shell. Damaged threads come from cross-threading a coupling nut started under load or from a stainless nut galled on a zinc body. Seal wear after repeated mating shows as a damp or corroded ring inside the coupling nut before the circuit fails, which is why the cycle rating is a service interval and not a footnote.

Repair means replacement. A pass-through is a fixed part with no adjustment, so a worn interface seal, a bent pin, or a stripped thread ends the part's life, and the question is only how fast it can be changed. Two things make that fast. The interface is standardized, so cordsets from several makers mate with it. The cable work is outside the part, so swapping it rewires nothing inside the enclosure. Spares worth holding are the feed-through itself, the seal screw or gasket ordered separately, the dust caps, and the protection cover. A fiber or coaxial feedthrough on a vacuum chamber is changed as a complete fitting, with a new copper gasket or a new fluororubber O-ring each time it is opened.

Check or failureWhat is foundAction
Panel sealDamp ring at the mounting nut; panel out of rangeRe-seat on a clean face with the correct seal; re-torque
Open face without capExposed contacts; no rating while unpluggedFit the dust cap or protection cover
ContactsBent or blackened pin; resistance stepReplace the feed-through; find the overload
Mounting threadsGalled or crossed nut; body turns in the holeChase or re-tap; fit a new nut with anti-seize
Shield bondHigh shell-to-panel resistance after repaintingStrip coating at the mounting face; re-measure
Seal wearDamp ring in the coupling nut; count near 100 cyclesReplace; move frequent unmating away from the wall
Contact heatingDiscolored insert; conductor above 4 AMove the load to a power feed-through
Shell corrosionBloom between a zinc body and a stainless panelFit an isolation washer or a stainless shell
Vacuum feedthroughLeak above 5 x 10^-10 mbar l/s after bakeoutLeak-test from the pin side; replace with new gasket
Chapter 6 / 06

Bulkhead Pass-Through Connector Applications and Procurement Checks

Factory automation is the natural home of the small circular feed-through, because a machine has many sensors and one cabinet. An M8 or A-coded M12 feed-through in the cabinet wall lets each proximity sensor, photoelectric sensor, or safety interlock switch arrive as a cordset, cross the wall mated, and continue inside as a second cordset to a remote IO module or a PLC. A device that speaks IO-Link crosses on the same A-coded parts, and an EtherCAT device on the D-coded Ethernet parts. A power cable crosses beside the signals on S-coded or L-coded M12 parts and on 7/8 inch feed-throughs: one maker quotes 620 V and 12 A for the S-coding and 63 V DC and 16 A for the L-coding, the rating that feeds a servo motor or a variable frequency drive without a terminal box at the wall.

Networks and machine vision use the same wall for a different reason: the cable must not be cut, because a cut and re-terminated Ethernet cable is a source of return loss. A D-coded M12 feed-through carries Ethernet and PROFINET at Cat 5 transmission performance, and an X-coded one carries Gigabit Ethernet on Cat 6A patch cables, with a shielded cable keeping its continuity through the metal body and the 360 degree termination. Outside the enclosure the cords drop from the cable tray or the machine frame to the wall; inside, the cable lands on an industrial switch, an industrial router, or a fieldbus gateway, and it runs out to a machine vision system or a code reader. Where a device offers only a fiber port, a fiber converter sits inside the cabinet and a fiber feedthrough carries the light where the wall is also a vacuum boundary.

Heavy industry, outdoor plant, and vacuum systems take the larger and the hermetic types. Rectangular panel feed through housings carry many auxiliary cores between the cable distribution cabinet and the compartments of switchgear, and the washdown grade is built for wet areas, where a hose is part of the daily routine. Military and aerospace equipment uses the jam nut and wall mount receptacles on firewalls and pressurized bays, a class offered with a 500 h salt spray finish and a 200 degrees Celsius (392 degrees F) limit. Vacuum coaters and surface analysis chambers take hermetic feedthroughs in sets: a sub-miniature D for a thermocouple and a vacuum gauge, a power feedthrough for a heater, a coaxial part for a radio-frequency source, and a fiber part for an optical probe, all on one chamber wall.

A purchase order for a bulkhead pass-through connector has to state six things and ask for four. State the interface on each face: coding, ways, and gender, and the standard the interface follows, such as IEC 61076-2-101 for M12. State the electrical duty: current per contact with all contacts loaded, voltage, and whether the circuit is signal, data, or power. State the panel: thickness at the hole, cut-out and thread, material, and coating. State the seal rating: the IP code required when mated, what the face must hold when open, and whether the part is washed down. State the environment: temperature range, salt spray, vibration, and any vacuum or pressure across the wall. State the termination on the inside: second mating face, terminals, or flying leads and their length. Ask for the test report behind each rating, for the tightening torque of the coupling nut and the mounting nut, for the mating-cycle rating of the part, and for the list of seals, screws, and caps ordered separately, because a housing can arrive without the part that makes it IP67.

FAQ

What does a bulkhead pass-through connector do, and how is it different from a cable gland?

A bulkhead pass-through connector is fixed in a rigid partition, a cabinet wall, an enclosure lid, a machine frame, or the wall of a vacuum vessel, and it carries a mating interface on each side. Two cordsets meet through the panel, the cable stays overmolded from end to end, and no conductor is cut or landed on a terminal at the wall. A cable gland is the neighboring device: it seals a cable that enters the enclosure and is wired to terminals inside, and it carries no contacts. The two are used together, with the gland on the cable entry of a hood that plugs into a panel feed through housing.

What types of bulkhead pass-through connector are available?

Six forms cover the market. Heavy-duty rectangular types are bulkhead mounted housings and panel feed through housings that take hoods on one or both faces. Circular M12 and M8 panel feed-throughs are thread-in double-ended receptacles with a mounting nut, finished with crimp terminals, insulation-displacement terminals, or flying leads. Thread-in power feed-throughs use 7/8 inch, Pg 13.5, or M20 mountings. Military jam nut receptacles and square-plate receptacles mate with series III plugs in shell sizes from 9 to 25. Hermetic glass-to-metal feedthroughs on vacuum fittings carry from 9 to 300 pins. Fiber-optic and coaxial bulkheads pass light and radio-frequency signals, the fiber type with size 16 termini in the military pattern.

Which specifications matter most on a bulkhead pass-through connector?

Read five lines on the datasheet. The rated current per contact, which falls from 4 A at 2 to 5 ways to 2 A at 6 to 8 ways on M12 types. The rated voltage of the part, 32 V or 50 V on M12 feed-throughs, although the M12 interface is standardized up to 250 V. The ingress protection with its condition, IP67 when mated and locked, and the rating of the housing when a hood or cap is removed. The panel thickness range and the mounting thread, 2.0 to 5.0 mm and M16 x 1.5 on the flying-lead M12 version. The mating-cycle rating, 100 on M8 and M12 feed-throughs and 500 on the military coupling.

How is the right bulkhead pass-through connector chosen?

Fix the interface on each face from the cordsets that will meet it, and put the sockets on the side that is exposed to damage. Add up the current in every contact with all contacts loaded; above the 4 A of an M12 signal part, move to a 7/8 inch or Pg 13.5 or M20 power feed-through rated 10 A or 16 A. Count the unmating operations a year at the wall and set them against the 100-cycle rating. Measure the panel thickness and confirm the cut-out. Then choose the shell and seal for the environment: stainless steel and IP69K for washdown, a 500 h salt spray finish outdoors, a glass-sealed fitting for vacuum.

How is a bulkhead pass-through connector installed and maintained?

Measure the panel thickness and cut the hole to the mounting style, deburred, with the coating removed around it on shielded versions. Insert the body from outside, run the mounting nut or jam nut down by hand, and tighten it with a torque wrench. Land the inside cable, clamp it close to the body, and mate both cordsets by hand before tightening the coupling nut to 0.6 Nm (0.44 lbf ft) on M12 or 0.4 Nm (0.30 lbf ft) on M8. Fit a cap on any open face. Maintenance is a visual check for corrosion, a resistance measurement from cordset to cordset, an insulation test, and a leak check after each bakeout on a vacuum feedthrough.

What affects the cost and lead time of a bulkhead pass-through connector?

Cost follows material, contact count, and certification. A plastic M12 feed-through with four crimp contacts is a catalog part; the same interface in a metal, shielded body with a 360 degree termination and an X-coded Cat 6A interface costs more because body, insulator, and testing change. Rectangular housings climb with size and with the finish: a washdown grade rated IP69K, a stainless steel housing, or a version with salt spray proofing to 500 h. Hermetic feedthroughs are the costly end, because each one is leak tested to below 5 x 10^-10 mbar l/s and the vacuum fitting is machined. Lead time lengthens for military-qualified parts and for any non-catalogued shell size or insert arrangement; standard interfaces ship fastest.

Which standards apply to bulkhead pass-through connectors, and what are the safety points?

IEC 61076-2-101 is the detail specification for M12 connectors, covering 2 to 17 ways at up to 250 V and 4 A per contact. IEC 61984 gives safety requirements and tests for connectors rated above 50 V up to 1000 V and up to 125 A per contact. UL 1977 covers component connectors for data, signal, control, and power, and IEC 60529 defines the IP codes. For safety, de-energize before unmating unless the datasheet states a breaking capacity, and check that the shell bonds to the panel so a fault current has a path. On a vacuum wall, respect the maximum differential pressure of 1 bar (14.5 psi) and the bakeout limit of 200 degrees Celsius (392 degrees F).

Sources

  1. IEC 61076-2-101, M12 connector detail specification
  2. HARTING M8 and M12 circular connectors catalog
  3. HARTING Han hoods and housings catalog
  4. Amphenol Aerospace bulkhead feed-through connector data sheet
  5. Allectra vacuum components catalog
  6. IEC 60529, degrees of protection provided by enclosures